background image

© Copyright 2001, ITT Industries

Printed in U.S.A.

All Rights Reserved

Form: 81000-343

11/01

UNITED KINGDOM
Flojet, Unit 1, Avant Business Centre
Denbigh West Industrial Estate
Milton Keynes, Bucks, England MK1 1DL
Tel: 44 1908 370088
Fax: 44 1908 373731

U.S.A.
Flojet
20 Icon
Foothill Ranch, CA 92610-3000
Tel: (949) 859-4945
Fax: (949) 859-1153

Standard installation of a three pump / three

transfer valve assembly on a riser/spacer

(See front mount)

Fig. #9

Standard five pump assembly installation

Fig. #10

Front

Mount

Side

Mount

Note:
Tygon Hose
Center Line Run

N5000-530

Front

Mount

Side

Mount

Note:
Tygon Hose
Center Line Run

N5000-530

Model N5000 Specifications

Pump Design

................Positive Displacement, Double Diaphragm

Power Source

........CO

2

Gas, Nitrogen or Compressed Filtered Air

Materials of Construction (wetted parts)

....................Celcon M90,

Santoprene

®

, EPDM, 302 or 304 Stainless Steel Spring

Temperature Limits

..................................34˚ - 120˚ F (1.1˚ - 49˚ C)

Weight

....................................................................1.22 lbs. (0.55 kg.)

Dimensions

..................................5-3/8" H x 6-7/32" W x 2-7/16" D

(135.7 mm x 157.9 mm x 61.9 mm)

Displacement

..........................................................2.5 oz. per cycle

Self Priming

......................................................Up to 10 ft. (3.05 m)

Operating Pressure

....20 psi (1.4 bar) min. / 80 psi (5.5 bar) max.

Liquid Inlet Pressure

......................................10 psi (0.7 bar) max.

Flow Rate

..................................4.0 oz. (118.3 ml)/sec. - Open Flow

Approvals

..................................................................NSF listed & CE

Vacuum Shutoff

......Automatically shuts off pump at 21" Hg when 

product supply is depleted. High altitude versions available for

installation where altitudes exceed 3,000 feet (914 m).

Features

1.

Supplies up to two fast flow or four standard flow dis-
pensing valves at remote locations.

2.

Fully automatic, operates only when beverage is
being dispensed and maintains constant pressure at
the dispensing valve.

3.

Shuts off automatically when bag is empty and
restarts when a full bag is connected.

4.

High suction capability empties the bag down to a
minimum residual.

5.

Brass tee and elbow CO

2

shutoff valve quick-discon-

nect allows us to manifold CO

2

inlet line.

6.

All pumps come with a stainless steel 3/8 inch (9.5
mm) product out barb port.

Accessories

Quantity

Part No.

Description

one

20590-000

Bracket for Pumps

one

20594-000

Bumper Guard

two

20595-000

Tube Hangers

one

1520-000

1/4 Inch (6.3 mm) Brass Tee
CO

2

Shutoff Valve

one

1521-000

1/4 Inch (6.3 mm) Brass Elbow
CO

2

Shutoff Valve

one

1500-030A

Transfer Valve

IF USED WITH CO

2

OR N

2

BE SURE THE AREA IS

WELL VENTILATED

ONLY USE PUMPS WITH SPECIFIED PRODUCTS. DO

NOT PUMP FLAMMABLE LIQUIDS OR USE WHERE

FLAMMABLE VAPORS ARE PRESENT

WARNING

AVAILABLE PORT FITTINGS

Gas Inlet:

• 1/4” (6.3mm) Barb, plastic, straight
• 1/4” (6.3mm) Barb, brass w/CO

2

shut-off - straight, tee

or elbow.

• John Guest for 1/4” O.D. tubing, plastic or brass

w/CO

2

shut-off

Gas Outlet

:

• 1/4” (6.3mm) Barb, plastic, straight

Product Inlet & Outlet:

• 1/4” (6.3mm) Barb, stainless steel, straight or elbow
• 3/8” (9.5mm) Barb, plastic, straight
• 3/8” (9.5mm) Barb, stainless steel, straight or elbow
• 1/2” (12.7mm) Barb, stainless steel, straight
• John Guest for 1/4” or 3/8” O.D. tubing, plastic

Summary of Contents for N5000 Series

Page 1: ...rflo products See fig 7 for proper removal of pumps Pump bracket assemblies transfer valve assemblies adapt to the Red Line bag in box rack See fig 6 for routing of hose and tube hangers All suction line lengths from pump inlet to box connec tor must not exceed 10 feet 3 m Transfer valve is located between pump and box and now includes 15 feet 4 6 m of hose for special applications Pumps must be a...

Page 2: ... gas pressure or manufacturer s maximum recommended pressure The Flojet Model N5000 has an automatic vacuum shutoff valve which stops the pump by shutting off the gas supply to the pump when the bag is empty and high vacuum builds up in the inlet syrup line The control will automatically restart the pump when a new bag is connected and vacuum in the inlet syrup line has returned to normal OPERATIO...

Page 3: ...de of pump with your fingers Do Not use a screw driver for removal of the pump to maintain future retainer bar assembly tension Note The CO2 manifold would change if a Shurflo pump is installed Fig 8 Standard installation of a three pump assembly without a transfer valve on a riser spacer See front mount Front Mount Side Mount Note Tygon Hose Center Line Run N5000 530 ...

Page 4: ...e for installation where altitudes exceed 3 000 feet 914 m Features 1 Supplies up to two fast flow or four standard flow dis pensing valves at remote locations 2 Fully automatic operates only when beverage is being dispensed and maintains constant pressure at the dispensing valve 3 Shuts off automatically when bag is empty and restarts when a full bag is connected 4 High suction capability empties...

Reviews: