TTCF-9B
Variable High Flow Heated
Hydraulic Component Flusher
40201507
QUICK START
INSTRUCTIONS
Flo-Dynamics, Inc. • 3300 Reedy Drive • Elkhart, IN 46514 • 800-303-5874
Page
1
of
4
OPERATION
SAFETY RECOMMENDATIONS
This machine uses hot hydraulic fluid under pressure. Check the security of all hoses and connections before operation.
Only use the same hydraulic fluid as used in the hydraulic system being flushed. DO NOT use mineral spirits, solvents, or any other volatile
liquid.
Always wear safety glasses, protective gloves, and proper clothing when operating the flusher.
If hydraulic fluid gets in your eyes or on your skin, rinse with water immediately and seek medical attention if needed.
WARNING: Improper use of this machine can result in burns and other serious injuries. Always wear eye protection and protective clothing
and follow instructions to prevent potential injury.
FLUSH PROCEDURE
Fill the tank with 10 gallons of hydraulic fluid or until fluid
level is halfway in sight glass.
WARNING: DO NOT OVERFILL or run with fluid level
higher than halfway in sight glass.
CAUTION: To prevent hydraulic fluid from overflowing
during a flush cycle or when air purging, do not run with
fluid higher than showing over halfway on the sight glass.
Plug the machine into a 20A grounded circuit without
anything else plugged in or being used on the circuit. If a
dedicated 20A circuit is not available, use two separate and
dedicated 15A outlets.
Connect the flusher to 100-125 PSI shop air.
Move the reverser valve to the bypass (middle) position.
CAUTION: Make sure the reverser valve is in the
neutral/bypass position prior to preheating.
PRIOR TO STARTING PREHEAT
o
Secure fill cap
o
Secure filter screen
o
Check fluid level
o
Check all connections
o
Ensure the reverser valve is in the bypass
(middle) position
Turn the Heater and Pump ON to begin heating the flusher
while connecting the services hoses to the component or
system being flushed.