ADDITIONAL FUNCTIONS
FILL THE TANK
Remove the fill cap and add enough hydraulic fluid to bring
the level to the middle of the sight glass.
CAUTION: To prevent hydraulic fluid from overflowing
during a flush cycle or when air purging, do not run with
fluid higher than showing over halfway on the sight glass.
Replace the fill cap when full level is reached.
DRAIN THE TANK USING THE MOTOR / PUMP
CAUTION: To prevent burns, only drain the system
when fluid is below 100 degrees.
Ensure the heater is OFF.
Connect the drain hose adapter to the red banded service
hose and place into a suitable waste container.
Move the reverser valve toward the red banded hose.
CAUTION: Fluid will drain at a high flow rate.
Turn the motor/pump ON and drain into waste container
until the unit stops flowing.
Turn the motor/pump OFF.
NOTE: After draining, there is still approximately one gallon
remaining in the tank. To completely drain, see “Completely
Drain the Tank for Fluid Type Change” procedure below.
COMPLETELY DRAIN THE TANK FOR FLUID TYPE CHANGE
Perform “Drain the Tank Using Motor/Pump” procedure
above.
Remove pump inlet hose pictured.
Place hose in a suitable waste container to gravity drain
remaining fluid in tank.
Replace inlet hose after draining.