ADDITIONAL FUNCTIONS 

 

FILL THE TANK 

Remove the fill cap and add enough hydraulic fluid to bring 

the level to the middle of the sight glass.  
CAUTION: To prevent hydraulic fluid from overflowing 

during a flush cycle or when air purging, do not run with 

fluid higher than showing over halfway on the sight glass.  
Replace the fill cap when full level is reached. 

 

 

 

DRAIN THE TANK USING THE MOTOR / PUMP 

CAUTION: To prevent burns, only drain the system 

when fluid is below 100 degrees. 
Ensure the heater is OFF
Connect the drain hose adapter to the red banded service 

hose and place into a suitable waste container. 
Move the reverser valve toward the red banded hose. 
CAUTION: Fluid will drain at a high flow rate. 
Turn the motor/pump ON and drain into waste container 

until the unit stops flowing. 
Turn the motor/pump OFF
NOTE: After draining, there is still approximately one gallon 

remaining in the tank. To completely drain, see “Completely 

Drain the Tank for Fluid Type Change” procedure below. 

 

 

 

 

 

 

 

COMPLETELY DRAIN THE TANK FOR FLUID TYPE CHANGE 

Perform “Drain the Tank Using Motor/Pump” procedure 

above. 
Remove pump inlet hose pictured. 
Place hose in a suitable waste container to gravity drain 

remaining fluid in tank. 
Replace inlet hose after draining. 

 

 

 