FLO-DYNAMICS TTCF-9B Quick Start Instructions Download Page 2

 

TTCF-9B 

Variable High Flow Heated 

Hydraulic Component Flusher

 

40201507 

QUICK START 

INSTRUCTIONS 

 

Flo-Dynamics, Inc.  •  3300 Reedy Drive  •  Elkhart, IN 46514  •  800-303-5874

 

 

 

 

          

       

Page 

2

 of 

4

 

Connect the red banded service hose to the component or 

cooler Outlet line and the black service hose to the Inlet 

line of component or cooling system.  
Once the unit reaches 135-140 degrees perform 

component or cooling system Initial Purge using the 

following steps: 

 

 

NOTE: To extend life of the flush tank fluid, it’s always 

good to purge existing dirty fluid from component or 

cooling system prior to flushing. Follow initial purge 

procedure below. 
INITIAL PURGE PRIOR TO FLUSHING 

o

 

Turn the motor/pump OFF

o

 

Remove the top half of the filter housing and 

place into a waste bucket/container. 

o

 

Move the reverser valve toward the red banded 

hose. 

CAUTION: When purging, the fluid will be HOT with a 

high flow rate! Wear protective gloves, clothing and 

safety glasses and ensure top half of filter housing is 

held into waste container being used. 

o

 

Turn the pump ON and purge approximately 1-2 

quarts of fluid or until cleaner fluid is observed. 

o

 

Turn motor/pump OFF.   

Clean the screen filter if needed and reassemble the filter 

housing. 

 

 

 

 

 

 

SETTING UP A FLUSH 
With component or cooling system connected and initially 

flushed move the reverser valve toward the red banded 

hose connected to the component or cooler system outlet. 
Select Air Agitation flush pattern by pressing the Air Agitate 

button. 

 

Red – Off, no air agitation 

 

Green – Low, single air pulse for low flow system 

 

Blue – High, two air pulses for high flow systems 

NOTE: Air pulsing does not start until 1:30 minutes 

into flushing    
Prior to starting flush: 

o

 

Secure fill cap 

o

 

Secure filter screen 

o

 

Check fluid level 

o

 

Check all connections 

Turn motor/pump and heater ON to begin flushing. 
Suggested to flush initially for 15 minutes. 

 

 

 

 

 

 

 

Reviews: