The Vibration Monitoring Solution is a powerful set of tools that require careful
attention and a fair number of steps to set up. Once setup is complete, how-
ever, the tools are automated and do not require adjustment unless changes
to the setup are needed.
Follow the quick steps in Section 5.1, below, for Standalone operation (mobile
device use only), or Section 5.2 if you are using a Windows PC and a mobile
device. Refer to Section 8.2,
Choosing PC-based or Standalone Control
, to
help you decide which route to take.
These steps will take you through the process of establishing communication
with the devices in your system. Once communication is established you can
continue with the remaining sections of this manual to set up sensors and ex-
plore the other capabilities of the monitoring system.
NOTE
•
The mobile device must be within 30 cm (12 inches) of the gateway during setup.
•
The sensors must be kept within 1.5 m (5 feet) of the gateway during setup.
5.1
Quick Steps for Standalone Operation
1. Plug the gateway into an AC outlet. The blue power LED and amber com-
munication LED will light. The communication LED turns green when com-
munication is established with the Wi-Fi network.
2. Download the FLIR Remote Monitoring app for Android (Google Play) or
iOS device (App Store).