Bonded ground system (preferred)
RF ground system (alternative)
1.
Power cable to product.
2. Drain (screen).
3.
Bonded (preferred) or non-bonded RF ground.
4.
Power supply or battery.
Implementation
If several items require grounding, they may first be connected to a single local point (e.g. within
a switch panel), with this point connected via a single, appropriately-rated conductor, to the
boat’s common ground. The preferred minimum requirement for the path to ground (bonded or
non-bonded) is via a flat tinned copper braid, with a 30 A rating (1/4 inch) or greater. If this is not
possible, an equivalent stranded wire conductor maybe used, rated as follows:
• for runs of <1 m (3 ft), use 6 mm
2
(#10 AWG) or greater.
• for runs of >1 m (3 ft), use 8 mm
2
(#8 AWG) or greater.
In any grounding system, always keep the length of connecting braid or wires as short as possible.
Important:
Do NOT connect this product to a positively-grounded power system.
References
• ISO10133/13297
• BMEA code of practice
42
Summary of Contents for Raymarine HD DIGITAL RADOME
Page 2: ......
Page 4: ......
Page 8: ...8...
Page 15: ...Chapter 3 Parts supplied Chapter contents 3 1 Parts Supplied on page 16 Parts supplied 15...
Page 18: ...4 1 Dimensions 18 inch antenna 18...
Page 19: ...4 2 Dimensions 24 inch antenna Product dimensions 19...
Page 20: ...20...
Page 28: ...28...
Page 32: ...7 3 Connection to G Series Display 32...
Page 46: ...46...
Page 49: ...Chapter 11 Operation Chapter contents 11 1 Operation instructions on page 50 Operation 49...
Page 53: ...Chapter 13 Troubleshooting Chapter contents 13 1 Troubleshooting on page 54 Troubleshooting 53...
Page 58: ...58...
Page 62: ......
Page 63: ......