Junction box accessory
Page 93
● The shield in the cable used to connect the external equipment
should be connected at one end only. Refer to the manufacturers
documentation regarding cable construction.
● The chassis connection can be made with
EITHER
a drain wire
OR
directly to the cable shield using exposed wire links on the junction
box printed circuit board, depending on the cable construction.
7.4 Technical information
7.4.1
Physical
7.4.2
Environmental
7.4.3
Data Connector Information
Junction box
dimensions
235mm x 69mm x 233mm (WxHxD)
Junction box
weight
0.65kg
Operating temperature
range
-25
°
C to +55
°
C tested to IEC 60945
‘Exposed’ category
Maximum operating
humidity
90% at +40
°
C, non-condensing
Water ingress rating
IPx6
18 way data
connector
Chogori
23018525-04-RC
Mating half
Chogori
23018221-01
14 way data
connector
Chogori
23014525-05-RC
Mating half
Chogori
23014221-01