427-0016-00-10 Revision 120
Copyright © 2008 FLIR Systems, Inc. 12
Note the following:
•
If Baud Rate is set to the slower values (2400 or 4800), some GUI commands (Get FPA
Temp, Get Version, Get Serial Number, etc) may not function properly due to the delays in
reading and writing the long command packets. It is recommended to use the fastest baud
rate possible.
•
The GUI will have an easier time connecting to the PTZ-35 MS / PTZ-50 MS if the hardware
is powered up prior to opening the software.
•
It is extremely important for the operator to know the Pelco address of the PTZ-35 MS /
PTZ-50 MS . If only one device is in use, it is recommended to keep the address at the
default setting (01). If the address is lost or forgotten, the operator will have to manually
search through the range of values (01-99).
•
Pelco address 08 is reserved for internal use by the PTZ-35 MS / PTZ-50 MS and cannot be
used anywhere else in the network.