427-0032-00-12, Version 170
Mar 2014
1-10
1
PT-Series Camera Installation
Other Serial Communication Parameters:
The tables below defines the switch locations, bit
numbering and on/off settings used in controlling the other serial communication parameters.
Table 1-2: Dip Switch Settings—SW103
Settings
Description
Baud rate:
This is the baud rate of the system user serial
port. The available values are 2400, 4800, 9600, 19200
kbaud.
Bit 1
Bit 2
OFF
OFF
2400
ON
OFF
4800
OFF
ON
9600
ON
ON
19200
Camera Control Protocol:
This is the communication
protocol selected for the system when operating over the
serial port. The available protocols are Pelco-D and
Bosch.
Bit 3
Bit 4
OFF
OFF
Pelco-D
ON
OFF
NA
OFF
ON
Bosch
ON
ON
NA
Serial Communication Standard:
This determines the
electrical interface selected for the user serial port. The
available settings are RS422 and RS232.
Bit 5
Bit 6
OFF
OFF
NA
ON
OFF
RS422
OFF
ON
RS232
ON
ON
N/A
Not Used
Bit 7
Bit 8
X
X
X
X
X
X
X
X
Software Override DIP Switch:
This setting determines
whether the system will use software settings for
configuration or if the dip switch settings will override the
software settings. Default is Off.
Bit 9
OFF
Software select
ON
Hardware select
Not Used
Bit 10
X
Summary of Contents for PT series
Page 1: ...Installation Manual PT Series ...
Page 16: ...1 PT Series Camera Installation 427 0032 00 12 Version 170 Mar 2014 1 12 ...
Page 44: ...2 Basic Operation and Configuration 427 0032 00 12 Version 170 Mar 2014 2 28 ...
Page 47: ...3 Serial Address Decimal To Binary Conversion 427 0032 00 12 version 170 Mar 2014 3 3 ...