FLIR EXTECH SDL310 User Manual Download Page 8

8                                          

 SDL310-EU-EN-V1.1-6/11

 

Set the Beeper Sound ON or OFF  

1. Access 

the 

bEEP

 parameter. 

2. 

Use the arrow keys to select ON (enable) or OFF (disable).   

3. 

Press ENTER to confirm setting. 

4. 

Press and hold the SET key for at least 1.5 seconds to exit to the normal operation mode (or 
simply wait 7 seconds for the meter to automatically switch to the normal operating mode). 

Numerical Setting (comma or decimal)  

European and USA numerical formats differ. The meter defaults to USA mode where a decimal 
point is used to separate units from tenths, i.e. 

20.00

; European formats use a comma, i.e. 

20,00

 to 

separate units from tenths. To change this setting: 
1. Access 

the 

dEC

 parameter as described in the Accessing Setup Mode section above. 

2. 

Use the arrow keys to select USA or EUro.   

3. 

Press ENTER to confirm setting. 

4. 

Press and hold the SET key for at least 1.5 seconds to exit to the normal operation mode (or 
simply wait 7 seconds for the meter to automatically switch to the normal operating mode). 

SD Card FORMATTING  

1. Access 

the 

Sd-F

 parameter. 

2. 

Use the arrow keys to select YES to format the card (select NO to abort). Note that all data on 
the card will be lost if formatting is attempted. 

3. 

Press ENTER to confirm selection. 

4. 

Press ENTER again to re-confirm. 

5. 

The meter will automatically return to the normal operating mode when formatting is complete. 
If not, press and hold the SET key for at least 1.5 seconds to exit to the normal operation 
mode. 

Set the Temperature Units of Measure (°C or °F)   

1. Access 

the 

t-CF

 parameter. 

2. 

Use the arrow keys to select °

C or 

°

F

.   

3. 

Press ENTER to confirm setting. 

4. 

Press and hold the SET key for at least 1.5 seconds to exit to the normal operation mode (or 
simply wait 7 seconds for the meter to automatically switch to the normal operating mode). 

Set the Temperature Thermocouple Type (J or K)   

1. Access 

the 

tYPE

 parameter. 

2. 

Use the arrow keys to select J or K.   

3. 

Press ENTER to confirm setting. 

4. 

Press and hold the SET key for at least 1.5 seconds to exit to the normal operation mode (or 
simply wait 7 seconds for the meter to automatically switch to the normal operating mode). 

Summary of Contents for EXTECH SDL310

Page 1: ...User s Guide Vane Thermo Anemometer Datalogger Model SDL310...

Page 2: ...rnational Safety Symbols This symbol adjacent to another symbol or terminal indicates the user must refer to the manual for further information Meter Description 1 Thermocouple input 2 Vane input plug...

Page 3: ...econd FPM feet per minute Km h kilometers per hour knots and mph miles per hour 1 Press and hold the UNIT key for at least 1 5 seconds to switch from one unit of measure to another 2 Note that pressin...

Page 4: ...the display backlight ON or OFF press and hold the backlight key for at least 1 5 seconds The meter will beep when switching the backlight ON or OFF unless the beeper is disabled as described in the...

Page 5: ...talogging mode press and hold the LOG key for at least 1 5 seconds Automatic Datalogging In automatic datalogging mode the meter takes and stores a reading at a user specified sampling rate onto SD ca...

Page 6: ...e PC does not have an SD card slot use an SD card adaptor available at most outlets where computer accessories are sold 4 Power the PC and run a spreadsheet software program Open the saved documents i...

Page 7: ...at SdF SD memory card Format t CF Select the Temperature unit of measure to C or F tYPE Select the thermocouple type to K or J Setting the Clock Time 1 Access the dAtE parameter 2 Use the arrow keys t...

Page 8: ...ch to the normal operating mode SD Card FORMATTING 1 Access the Sd F parameter 2 Use the arrow keys to select YES to format the card select NO to abort Note that all data on the card will be lost if f...

Page 9: ...e rear of the meter directly above the top of the tilt stand 2 Remove and safely place the battery compartment and screws where they will not be damaged or lost 3 Replace the six 6 1 5V AA batteries o...

Page 10: ...atic temperature compensation for the Anemometer function and the type K J thermometer function Data Hold Freeze the display reading Memory Recall Record and Recall the Maximum and Minimum readings Di...

Page 11: ...8 C 1 5 F Type K J Thermocouple Thermometer Temperature Sensor Type Resolution Range Accuracy 0 1 C 50 0 to 1300 0 C 100 0 to 50 1C 0 4 0 5 C 0 4 1 C Type K 0 1 F 58 0 to 2372 0 F 148 0 to 58 1 F 0 4...

Reviews: