FLIR EXTECH SDL310 User Manual Download Page 2

2                                          

 SDL310-EU-EN-V1.1-6/11

 

Introduction 

Congratulations on your purchase of the Extech SDL300 Thermo-Anemometer Datalogger. This 
meter displays and stores air velocity and temperature readings. Temperature readings from the 
thermometer built into the vane probe or from an externally connected type K or J thermocouple 
temperature probe can be displayed and recorded. Data is stored on an SD card for transfer to a 
PC. In addition, an RS232 port allows data streaming to a PC. This meter is shipped fully tested and 
calibrated and, with proper use, will provide years of reliable service. 

 
 

Safety 

International Safety Symbols 

This symbol, adjacent to another symbol or terminal, indicates the user must refer to the 
manual for further information. 
 

 

Meter Description 

1. Thermocouple 

input 

2. 

Vane input plug 

3. 

Air velocity reading 

4. 

Units of measure 

5. HOLD 

Backlight   key 

6. MAX-MIN 

key 

7. 

SET and Clock 

  key 

8. 

PC interface jack 

9. Reset 

key 

10.  Power Adaptor jack 
11.  SD card slot 
12.  ENTER and LOG key 
13. Down 

arrow and FUNCTION key 

14. Up 

 arrow and UNITS key 

15. Power 

ON-OFF  key 

16.  Temperature reading with units of measure 
17. Anemometer 

vane 

18.  Colored dot faces the air flow 
19. Vane 

handle 

20.  Vane connecting cable 

 

Notes:

 

Battery compartment, tilt stand, and tripod mount are located on the rear of the instrument. 

Items 8, 9, and 10 are located behind the snap-off compartment cover on right side of meter. 

Summary of Contents for EXTECH SDL310

Page 1: ...User s Guide Vane Thermo Anemometer Datalogger Model SDL310...

Page 2: ...rnational Safety Symbols This symbol adjacent to another symbol or terminal indicates the user must refer to the manual for further information Meter Description 1 Thermocouple input 2 Vane input plug...

Page 3: ...econd FPM feet per minute Km h kilometers per hour knots and mph miles per hour 1 Press and hold the UNIT key for at least 1 5 seconds to switch from one unit of measure to another 2 Note that pressin...

Page 4: ...the display backlight ON or OFF press and hold the backlight key for at least 1 5 seconds The meter will beep when switching the backlight ON or OFF unless the beeper is disabled as described in the...

Page 5: ...talogging mode press and hold the LOG key for at least 1 5 seconds Automatic Datalogging In automatic datalogging mode the meter takes and stores a reading at a user specified sampling rate onto SD ca...

Page 6: ...e PC does not have an SD card slot use an SD card adaptor available at most outlets where computer accessories are sold 4 Power the PC and run a spreadsheet software program Open the saved documents i...

Page 7: ...at SdF SD memory card Format t CF Select the Temperature unit of measure to C or F tYPE Select the thermocouple type to K or J Setting the Clock Time 1 Access the dAtE parameter 2 Use the arrow keys t...

Page 8: ...ch to the normal operating mode SD Card FORMATTING 1 Access the Sd F parameter 2 Use the arrow keys to select YES to format the card select NO to abort Note that all data on the card will be lost if f...

Page 9: ...e rear of the meter directly above the top of the tilt stand 2 Remove and safely place the battery compartment and screws where they will not be damaged or lost 3 Replace the six 6 1 5V AA batteries o...

Page 10: ...atic temperature compensation for the Anemometer function and the type K J thermometer function Data Hold Freeze the display reading Memory Recall Record and Recall the Maximum and Minimum readings Di...

Page 11: ...8 C 1 5 F Type K J Thermocouple Thermometer Temperature Sensor Type Resolution Range Accuracy 0 1 C 50 0 to 1300 0 C 100 0 to 50 1C 0 4 0 5 C 0 4 1 C Type K 0 1 F 58 0 to 2372 0 F 148 0 to 58 1 F 0 4...