FLIR EXTECH SDL310 User Manual Download Page 6

6                                          

 SDL310-EU-EN-V1.1-6/11

 

SD Data Card to PC Data Transfer  

1. 

Complete a datalogging session as covered above. For the first test, simply record a small 
amount of test data. 

2. 

With the meter switched OFF, remove the SD Card. 

3. 

Plug the SD Card directly into a PC SD card reader. If the PC does not have an SD card slot, 
use an SD card adaptor (available at most outlets where computer accessories are sold). 

4. 

Power the PC and run a spreadsheet software program. Open the saved documents in the 
spreadsheet software program (see examples of spreadsheet displays below). 

 

Spreadsheet data example 

 

 

 

Spreadsheet example (Plotting the data) 

 

RS-232/USB PC Interface  

The optional 407001A software kit (software and cable) allows streaming of data to a PC via 
the RS232 Output jack. 

Summary of Contents for EXTECH SDL310

Page 1: ...User s Guide Vane Thermo Anemometer Datalogger Model SDL310...

Page 2: ...rnational Safety Symbols This symbol adjacent to another symbol or terminal indicates the user must refer to the manual for further information Meter Description 1 Thermocouple input 2 Vane input plug...

Page 3: ...econd FPM feet per minute Km h kilometers per hour knots and mph miles per hour 1 Press and hold the UNIT key for at least 1 5 seconds to switch from one unit of measure to another 2 Note that pressin...

Page 4: ...the display backlight ON or OFF press and hold the backlight key for at least 1 5 seconds The meter will beep when switching the backlight ON or OFF unless the beeper is disabled as described in the...

Page 5: ...talogging mode press and hold the LOG key for at least 1 5 seconds Automatic Datalogging In automatic datalogging mode the meter takes and stores a reading at a user specified sampling rate onto SD ca...

Page 6: ...e PC does not have an SD card slot use an SD card adaptor available at most outlets where computer accessories are sold 4 Power the PC and run a spreadsheet software program Open the saved documents i...

Page 7: ...at SdF SD memory card Format t CF Select the Temperature unit of measure to C or F tYPE Select the thermocouple type to K or J Setting the Clock Time 1 Access the dAtE parameter 2 Use the arrow keys t...

Page 8: ...ch to the normal operating mode SD Card FORMATTING 1 Access the Sd F parameter 2 Use the arrow keys to select YES to format the card select NO to abort Note that all data on the card will be lost if f...

Page 9: ...e rear of the meter directly above the top of the tilt stand 2 Remove and safely place the battery compartment and screws where they will not be damaged or lost 3 Replace the six 6 1 5V AA batteries o...

Page 10: ...atic temperature compensation for the Anemometer function and the type K J thermometer function Data Hold Freeze the display reading Memory Recall Record and Recall the Maximum and Minimum readings Di...

Page 11: ...8 C 1 5 F Type K J Thermocouple Thermometer Temperature Sensor Type Resolution Range Accuracy 0 1 C 50 0 to 1300 0 C 100 0 to 50 1C 0 4 0 5 C 0 4 1 C Type K 0 1 F 58 0 to 2372 0 F 148 0 to 58 1 F 0 4...