background image

Working with measurement tools

16

8. Use the navigation pad to change the parameter.
9. Push the navigation pad. This closes the dialog box.

10. When completed, push the navigation pad and select

(

Done

).

11. Push the navigation pad to confirm and exit the menu mode.

Note

When you select another measurement tool, the local parameters are reset. If you

wish to keep the local parameter settings, use the user preset feature, see section 16.3

Editing user presets

page 75.

16.5.5

Related topics

For in-depth information about parameters, and how to correctly set the emissivity and re-
flected apparent temperature, see section 33

Thermographic measurement techniques

,

page 250.

16.6

Displaying values in the result table

16.6.1

General

For the box and circle tools, you can set the camera to display the maximum, minimum,
average, and area values in the result table.

16.6.2

Procedure

Follow this procedure:

1. To select the measurement tool, touch the tool on the screen. The tool is now dis-

played with one or more handles.

2. Push the navigation pad—or touch and hold the tool. This displays a context menu.

3. Use the navigation pad to select

(

Max/Min/Avg

).

4. Push the navigation pad. This displays a submenu.

#T810190; r. AJ/46209/46209; en-US

80

Summary of Contents for E75

Page 1: ...User s manual FLIR Exx series Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com ...

Page 2: ......

Page 3: ...User s manual FLIR Exx series T810190 r AJ 46209 46209 en US iii ...

Page 4: ......

Page 5: ...1 General 9 4 2 Submitting a question 9 4 3 Downloads 10 5 List of accessories and services 11 6 Quick start guide 12 6 1 Procedure 12 6 2 To keep in mind 12 7 Register the camera 13 7 1 General 13 7 2 Procedure 13 8 Camera parts 18 8 1 View from the front 18 8 1 1 Figure 18 8 1 2 Explanation 18 8 2 View from the rear 19 8 2 1 Figure 19 8 2 2 Explanation 19 8 3 Laser distance meter and laser point...

Page 6: ...1 11 5 2 Figure 31 11 5 3 Procedure 31 11 6 Continuous autofocus 32 11 6 1 General 32 11 6 2 Procedure 32 11 7 Saving an image 33 11 8 Operating the laser distance meter 33 11 8 1 General 33 11 8 2 Figure 34 11 8 3 Procedure 34 11 9 Measuring areas 35 11 9 1 General 35 11 9 2 Procedure 35 11 10 Connecting external devices and storage media 35 11 10 1 General 35 11 10 2 Figure 36 11 10 3 Explanatio...

Page 7: ... Procedure 55 12 4 Opening a saved image 55 12 4 1 General 55 12 4 2 Procedure 55 12 5 Editing a saved image 56 12 5 1 General 56 12 5 2 Procedure 56 12 5 3 Related topics 56 12 6 Displaying the image information 56 12 6 1 General 56 12 6 2 Procedure 56 12 7 Zooming an image 57 12 7 1 General 57 12 7 2 Procedure 57 12 8 Deleting images 57 12 9 Resetting the image counter 57 12 9 1 General 57 12 9 ...

Page 8: ...4 2 Procedure 67 14 5 Changing the color palettes 68 14 5 1 General 68 14 5 2 Procedure 69 14 6 Changing the measurement parameters 69 14 7 Performing a non uniformity correction NUC 70 14 7 1 General 70 14 7 2 Performing an NUC manually 70 14 8 Hiding all overlay 70 14 8 1 General 70 14 8 2 Procedure 71 15 Working with image modes 72 15 1 General 72 15 2 Image examples 72 15 3 Selecting an image ...

Page 9: ...g isotherms 87 18 Annotating images 89 18 1 General 89 18 2 Adding a note 89 18 2 1 General 89 18 2 2 Procedure 89 18 3 Adding a text comment table 90 18 3 1 General 90 18 3 2 Procedure 90 18 3 3 Creating a text comment table template 91 18 4 Adding a voice annotation 93 18 4 1 General 93 18 4 2 Procedure 93 18 5 Adding a sketch 94 18 5 1 General 94 18 5 2 Procedure 94 19 Programming the camera ti...

Page 10: ...6 1 Camera housing cables and other items 110 26 1 1 Liquids 110 26 1 2 Equipment 110 26 1 3 Procedure 110 26 2 Infrared lens 110 26 2 1 Liquids 110 26 2 2 Equipment 110 26 2 3 Procedure 110 26 3 Infrared detector 111 26 3 1 General 111 26 3 2 Procedure 111 27 Technical data 112 27 1 Online field of view calculator 112 27 2 Note about technical data 112 27 3 Note about authoritative versions 112 2...

Page 11: ...rmographic measurement techniques 250 33 1 Introduction 250 33 2 Emissivity 250 33 2 1 Finding the emissivity of a sample 250 33 3 Reflected apparent temperature 254 33 4 Distance 254 33 5 Relative humidity 254 33 6 Other parameters 254 34 About calibration 255 34 1 Introduction 255 34 2 Definition what is calibration 255 34 3 Camera calibration at FLIR Systems 255 34 4 The differences between a c...

Page 12: ...fan Boltzmann s law 265 36 3 4 Non blackbody emitters 266 36 4 Infrared semi transparent materials 268 37 The measurement formula 269 38 Emissivity tables 273 38 1 References 273 38 2 Tables 273 T810190 r AJ 46209 46209 en US xii ...

Page 13: ...surance The Quality Management System under which these products are developed and manufactured has been certified in accordance with the ISO 9001 standard FLIR Systems is committed to a policy of continuous development therefore we reserve the right to make changes and improvements on any of the prod ucts without prior notice 1 7 Patents 000439161 000653423 000726344 000859020 001707738 001707746...

Page 14: ...re Foundation either version 2 1 of the License or at your op tion any later version This library is distributed in the hope that it will be useful but WITHOUT ANY WARRANTY without even the implied warranty of MER CHANTABILITYor FITNESS FOR A PARTICULAR PURPOSE See the GNU Lesser General Public License http www gnu org licenses lgpl 2 1 html The source code for the libraries Qt4 Core and Qt4 GUI m...

Page 15: ...s with Part 15 of the FCC Rules and with RSS 210 of Industry Canada Op eration is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation WARNING Applicability Digital devices subject to 15 21 NOTICE Changes or modifications made to this equipment not e...

Page 16: ...rrect flow of current to the battery can occur This can cause the battery to be come hot or cause an explosion Injury to persons can occur WARNING Make sure that you read all applicable MSDS Material Safety Data Sheets and warning labels on con tainers before you use a liquid The liquids can be dangerous Injury to persons can occur CAUTION Do not point the infrared camera with or without the lens ...

Page 17: ...he battery be comes hot damage can occur to the safety equipment and this can cause more heat damage or ignition of the battery CAUTION Applicability Cameras with one or more batteries Do not put the battery on a fire or increase the temperature of the battery with heat Damage to the battery and injury to persons can occur CAUTION Applicability Cameras with one or more batteries Do not put the bat...

Page 18: ...ty Cameras with one or more batteries When the battery is worn apply insulation to the terminals with adhesive tape or equivalent materials be fore you discard it Damage to the battery and injury to persons can occur if you do not do this CAUTION Applicability Cameras with one or more batteries Remove any water or moisture on the battery before you install it Damage to the battery can occur if you...

Page 19: ...at may be hazardous and present a risk to human health and the environment when waste electrical and electronic equipment WEEE is not handled correctly Equipment marked with the below crossed out wheeled bin is electrical and electronic equipment The crossed out wheeled bin symbol indicates that waste electrical and elec tronic equipment should not be discarded together with unseparated household ...

Page 20: ... of manuals for our other products as well as manuals for our historical and obsolete products 3 7 Important note about this manual FLIR Systems issues generic manuals that cover several cameras within a model line This means that this manual may contain descriptions and explanations that do not apply to your particular camera model 3 8 Note about authoritative versions The authoritative version o...

Page 21: ...nswers you do not need to be a registered user When you want to submit a question make sure that you have the following information to hand The camera model The camera serial number The communication protocol or method between the camera and your device for ex ample SD card reader HDMI Ethernet USB or FireWire Device type PC Mac iPhone iPad Android device etc Version of any programs from FLIR Syst...

Page 22: ...or your infrared camera Program updates for your PC Mac software Freeware and evaluation versions of PC Mac software User documentation for current obsolete and historical products Mechanical drawings in dxf and pdf format Cad data models in stp format Application stories Technical datasheets Product catalogs T810190 r AJ 46209 46209 en US 10 ...

Page 23: ...99588 Lens 24 case T199589 Lens 42 case T199590 Power supply for battery charger T911633ACC Power supply for camera 15 W 3 A T911630ACC USB 2 0 A to USB Type C cable 0 9 m T911631ACC USB Type C to HDMI adapter standard specifica tion UH311 T911632ACC USB Type C to USB Type C cable USB 2 0 stand ard 1 0 m T911705ACC Note FLIR Systems reserves the right to discontinue models parts or accessories and...

Page 24: ...ges into FLIR Tools Tools or FLIR Report Studio and create an inspec tion report 13 Send the inspection report to your client 6 2 To keep in mind Adjust the focus first When the camera is out of focus the measurement will be wrong By default most cameras adapt the scale automatically Use this mode first but do not hesitate to set the scale manually A thermal camera has a resolution limit This depe...

Page 25: ... you can use the same login cre dentials To complete the registration you must enter a four digit verification code into the camera 7 2 Procedure Follow this procedure 1 Use a computer or other device with internet access and go to the following website This displays the following dialog 2 To log in with your existing FLIR Customer Support account do the following 2 1 Enter your Username and Passw...

Page 26: ...he required information and click Create Account 4 On the camera select Settings Device settings Camera information Regis ter camera This displays the following dialog box Note The first time you start the camera the registration dialog box is displayed as a part of the setup of regional settings T810190 r AJ 46209 46209 en US 14 ...

Page 27: ...sh the navigation pad This displays a dialog box with the serial number of the camera 6 On the computer enter the serial number of the camera and click Validate 7 When the serial number is validated click Continue T810190 r AJ 46209 46209 en US 15 ...

Page 28: ...n the registration is completed the four digit code is displayed Note The code is also sent by e mail to the address registered with your FLIR Customer Support account The code is also displayed in your FLIR Customer Support portal under My Stuff Products T810190 r AJ 46209 46209 en US 16 ...

Page 29: ...select a digit Push the navigation pad left right to navigate to the previous next digit When all digits have been entered push the navigation pad right to select Submit Push the navigation pad to confirm 11 The camera is now registered and your extended warranty is activated T810190 r AJ 46209 46209 en US 17 ...

Page 30: ...ion 1 Laser distance meter 2 Infrared lens 3 Focus ring 4 Autofocus button 5 Trigger 6 Lamp for the digital camera left and right sides 7 Digital camera 8 Attachment point for the hand strap bracket left and right sides 9 Tripod mount T810190 r AJ 46209 46209 en US 18 ...

Page 31: ...p or lanyard strap left and right sides 8 2 View from the rear 8 2 1 Figure 8 2 2 Explanation 1 Cover for the USB connector and memory card slot 2 Microphone 3 Speaker 4 Touch screen LCD 5 Image archive button 6 Programmable button T810190 r AJ 46209 46209 en US 19 ...

Page 32: ...o the laser beam The laser beam can cause eye irritation Note The laser is enabled by a setting Select Settings Device settings Lamp la ser Enable lamp laser The symbol is displayed on the screen when the laser is on The camera can be configured to automatically measure the distance when an image is saved Select Settings Save options storage Measure distance With this setting the Object distance p...

Page 33: ...tter and receiver 1 Laser transmitter 2 Laser receiver 8 3 3 Difference in position This figure shows the difference in position between the laser transmitter and the optical center of the infrared lens T810190 r AJ 46209 46209 en US 21 ...

Page 34: ...ing information is attached to the camera 8 3 5 Laser rules and regulations Wavelength 650 nm Maximum output power 1 mW This product complies with 21 CFR 1040 10 and 1040 11 except for deviations pursuant to Laser Notice No 50 dated June 24 2007 T810190 r AJ 46209 46209 en US 22 ...

Page 35: ...g spotmeter 4 Temperature scale 5 Menu system button 9 2 Menu system To display the menu system push the navigation pad or tap the menu system button 1 Temperature scale button 2 Measurement parameters button 3 Image mode button 4 Measurement button T810190 r AJ 46209 46209 en US 23 ...

Page 36: ...dicator is green When the battery status is below 20 the indi cator is red The remaining storage capacity is below 100 MB A Bluetooth headset is connected External infrared window compensation is enabled The laser is on 9 4 Swipe down menu To open the swipe down menu place your finger at the top of the screen and swipe down 1 Battery status indicator 2 Memory card storage status indicator T810190 ...

Page 37: ...ion button Touch to enable disable screen rotation 4 Screen brightness slider Used to control the brightness of the screen 9 5 Image overlay information The image information consists of items such as the date emissivity and atmospheric temperature All image information is saved in the image file and can be viewed in the im age archive You can also choose to display selected items as image overlay...

Page 38: ... pad is used but most tasks can also be carried out using your index finger or a stylus pen 10 2 Navigating using the navigation pad You navigate the menu system by using the navigation pad and the back button To display the menu system push the center of the navigation pad To navigate in menus submenus and dialog boxes and to change values in dialog boxes push the navigation pad up down or left r...

Page 39: ...ble 11 1 2 Using the USB battery charger to charge the battery 11 1 2 1 Procedure Follow this procedure 1 Put the battery into the battery compartment of the camera 2 Connect the USB battery charger to a mains socket 3 Fold up the rubber cover at the top of the camera 4 Connect the USB connector of the USB battery charger to the USB C connector in the connector bay of the camera T810190 r AJ 46209...

Page 40: ...nal Explanation The white LED flashes The battery is being charged The white LED glows continuously The battery is fully charged 11 1 3 2 Procedure Follow this procedure 1 Put one or two batteries in the battery charger 2 Connect the power supply cable plug to the connector on the battery charger 3 Connect the power supply mains electricity plug to a mains socket 4 When the white LED on the batter...

Page 41: ...To charge the camera the computer must be turned on Charging the camera using a USB cable connected to a computer takes considerably longer than using the USB battery charger or the stand alone battery charger 11 2 Removing the battery Follow this procedure 1 Turn off the camera 2 Remove the battery from the camera T810190 r AJ 46209 46209 en US 29 ...

Page 42: ...focus manually 11 4 1 Figure 11 4 2 Procedure Follow this procedure 1 Do one of the following For far focus rotate the focus ring clockwise with the LCD screen facing toward you For near focus rotate the focus ring counter clockwise with the LCD screen facing toward you Note Do not touch the lens surface when you adjust the infrared camera focus manually If this happens clean the lens according to...

Page 43: ...ge contrast Laser The focus is based on a laser distance measurement The laser is used when the camera is autofocusing The focus method is configured by a setting Select Settings Device settings Fo cus Auto focus and then select Contrast or Laser 11 5 2 Figure 11 5 3 Procedure WARNING Do not point the camera at the face of a person when you use the autofocus function You can set the camera to use ...

Page 44: ...rritation Note Before you can enable continuous autofocus you need to enable the laser and select laser as focus method See section 11 6 2 Procedure page 32 When continuous autofocus is enabled it is not possible to manually adjust the focus by rotating the focus ring 11 6 2 Procedure Follow this procedure 1 Push the navigation pad to display the menu system 2 Select Settings and push the navigati...

Page 45: ...1 General The laser distance meter consists of a laser transmitter and a laser receiver The laser dis tance meter determines the distance to a target by measuring the time it takes for a laser pulse to reach the target and return to the laser receiver This time is converted to a dis tance which is displayed on the screen The laser receiver also works as a laser pointer When the laser distance mete...

Page 46: ...rameters page 77 in the image data is automatically updated with the measured distance when an image is saved There is no effect on the Object distance setting in live mode If the target reflection is low or if the target is angled from the laser beam there may be no return signal and the distance cannot be measured The laser distance meter may not be enabled in all markets 11 8 2 Figure 11 8 3 Pr...

Page 47: ... Device settings Lamp laser Enable lamp laser Follow this procedure 1 Add a box or circle measurement tool see section 16 2 Adding removing measure ment tools page 75 2 Set the camera to measure and display the area of the box or circle see section 16 6 Displaying values in the result table page 80 3 Make sure that the box or circle tool is in the center of the image see section 16 4 Moving and re...

Page 48: ... LED is flashing 2 SD memory card 3 USB C cable 11 11 Moving files to a computer 11 11 1 General When you save an image or video clip in the image archive of the camera the file is stored on the memory card You can connect the camera to a computer using a USB C to USB A or a USB C to USB C cable Once connected you can move the image and video files from the memory card to the computer T810190 r AJ...

Page 49: ... Connect the other end of the USB cable to the computer 3 Turn on the camera 4 Do one of the following Move the files to the computer using a drag and drop operation in Microsoft Win dows Explorer Note Moving a file using a drag and drop operation does not delete the file in the camera Import the images into FLIR Tools Tools or FLIR Report Studio T810190 r AJ 46209 46209 en US 37 ...

Page 50: ...n 15 Working with image modes page 72 Switch Thermal Thermal MSX Switch between the image modes Thermal and Ther mal MSX For more information see section 15 Working with image modes page 72 Switch 1x zoom Max zoom Switch between the digital zoom factor of 1 and maxi mum zoom Switch camera flash On Off Switch between the enabled disabled camera flash functions For more information see section 11 13...

Page 51: ...o display the menu system 2 Select Settings and push the navigation pad This displays the Settings menu 3 Use the navigation pad to select Device settings Lamp laser 4 Do one of the following To enable the camera lamp function select Enable lamp laser and push the navi gation pad To turn on off the camera lamp use the swipe down menu see section 9 4 Swipe down menu page 24 To enable the flash func...

Page 52: ...Handling the camera 11 T810190 r AJ 46209 46209 en US 40 ...

Page 53: ...4 2 Mounting the hand strap Follow this procedure 1 Fit the upper part of the hand strap into the bracket 2 Fit the bracket in place on the camera and tighten the screw with the supplied Torx key T810190 r AJ 46209 46209 en US 41 ...

Page 54: ...Handling the camera 11 3 Thread the loose strap through the attachment point at the base of the camera Secure the strap with the hook and loop fastener T810190 r AJ 46209 46209 en US 42 ...

Page 55: ...Handling the camera 11 11 15 Lanyard strap 11 15 1 General T810190 r AJ 46209 46209 en US 43 ...

Page 56: ...g with the FLIR logo part thread the lanyard strap through the attachment point at the base of the camera 3 Pull the entire lanyard strap through the attachment point until it stops 11 16 Wrist strap 11 16 1 General The wrist strap can also be used to attach a carabiner to the camera T810190 r AJ 46209 46209 en US 44 ...

Page 57: ...ollow this procedure 1 Remove the camera battery 2 Fold the wrist strap Make sure that the part with the FLIR logo faces away from the bend 3 Thread the bent wrist strap through the attachment point at the base of the camera T810190 r AJ 46209 46209 en US 45 ...

Page 58: ...rist strap through the attachment point until it stops 11 17 Front protection To protect the camera lens and the laser distance meter you can attach the front protec tion by using the supplied fastening device T810190 r AJ 46209 46209 en US 46 ...

Page 59: ...ting the lens camera combination page 50 for information on how to do this Note Do not touch the lens surface when you change lenses If this happens clean the lens according to the instructions in 26 2 Infrared lens page 110 Follow this procedure 1 Take a firm grip around the inner ring of the lens Rotate the inner ring 30 counter clockwise until it stops 2 Carefully pull out the lens T810190 r AJ...

Page 60: ...r follow the instructions in 26 3 Infrared detector page 111 4 Make sure that the inner ring of the camera lens is fully in its open position Correct The tooth 1 is in its end position at the black stop pin 2 Wrong You must rotate the inner ring until the tooth 1 reaches the black stop pin 2 T810190 r AJ 46209 46209 en US 48 ...

Page 61: ...he lens into position 6 Rotate the inner ring of the lens 30 clockwise The lens makes a click when it locks in place 7 Make sure that the two index marks are aligned indicating that the lens is locked in place T810190 r AJ 46209 46209 en US 49 ...

Page 62: ...viously had to be performed by a FLIR service department but for the FLIR Exx series the calibration can be performed by the user This feature is called AutoCal The AutoCal procedure requires a calibration target which is included in the lens package 11 19 2 AutoCal procedure Follow this procedure 1 Dip the calibration target in water for 1 second and let the excess drip off T810190 r AJ 46209 462...

Page 63: ...mera lenses page 47 When the lens is mounted the calibration wizard starts automatically 4 From a distance of 2 m 6 6 ft aim the camera toward the crosshair using the laser pointer The camera will take a picture automatically NOTE Make sure the camera s optical path is perpendicular to the calibration target See the image below T810190 r AJ 46209 46209 en US 51 ...

Page 64: ... is calibrated every time you move the camera to a new location 11 20 1 Procedure Follow this procedure 1 Push the navigation pad to display the menu system 2 Select Settings and push the navigation pad This displays the Settings menu 3 Use the navigation pad to select Device settings Geolocation Compass 4 If the Compass check box is unchecked push the navigation pad to enable the compass 5 Select...

Page 65: ...uations Select Settings Save options storage Digital camera Off When the digital camera is off fea tures that require visual information such as the images modes Thermal MSX and Pic ture in picture are disabled 12 1 2 File naming convention The default naming convention for image files is FLIRxxxx jpg where xxxx is a unique counter It is also possible to save images with a date prefix added to the...

Page 66: ...r conditions that help to achieve a good quality UltraMax image FLIR Tools Tools and FLIR ResearchIR Max have the ability to process UltraMax images Other FLIR software will treat the image as a regular image To configure the camera for UltraMax select Settings Save options storage Im age resolution UltraMax 12 2 Saving an image 12 2 1 General You can save images to the memory card 12 2 2 Procedur...

Page 67: ... mode without saving push the back button 12 4 Opening a saved image 12 4 1 General When you save an image the image file is stored on the memory card To display the im age again open it from the image archive Gallery 12 4 2 Procedure Follow this procedure 1 Push the image archive button This displays the Gallery with one or more folders 2 Select a folder and push the navigation pad 3 Select the i...

Page 68: ...lays a context menu Select Cancel to exit edit mode Select Measurement parameters to change the global parameters Select Image mode to change the image mode Select Measurement to add a measurement tool Select Color to change the color palette or set a color alarm Select Save to save and exit edit mode 12 5 3 Related topics 14 6 Changing the measurement parameters page 69 15 Working with image mode...

Page 69: ...s and on saved images in edit mode The digital zoom factor is displayed at the top of the screen 12 7 2 Procedure Follow this procedure 1 To digitally zoom an image do the following Zoom in Touch the screen with two fingers and spread the fingers apart Zoom out Touch the screen with two fingers and pinch the fingers together 12 8 Deleting images You can delete image files from the memory card For ...

Page 70: ...ure Follow this procedure 1 Push the navigation pad to display the menu system 2 Select Settings and push the navigation pad This displays the Settings menu 3 Use the navigation pad to select Device settings Reset options Reset image counter 4 Push the navigation pad This displays a dialog box 5 To reset the counter select Reset and push the navigation pad T810190 r AJ 46209 46209 en US 58 ...

Page 71: ...and delete folders 13 2 Opening image and video files Follow this procedure 1 Push the image archive button This displays the Gallery with one or more folders 2 Select a folder and push the navigation pad 3 Select the image or video clip you want to view and push the navigation pad 4 To view the previous next image or video clip push the navigation pad left right 5 To return to the folder overview...

Page 72: ...eted touch Done on the soft keyboard 13 5 Changing the active folder 13 5 1 General New images and video clips are saved to the active folder 13 5 2 Procedure Follow this procedure 1 Push the image archive button This displays the Gallery 2 On the top toolbar select the icon and push the navigation pad 3 Select the folder that new images and video clips should be saved to and push the navigation p...

Page 73: ...Select the folder to delete and push the navigation pad 4 On the right toolbar select the icon and push the navigation pad This displays a dialog box 5 To delete the folder select Delete and push the navigation pad 13 8 Deleting an image or video file 13 8 1 General You can delete an image or video file from the image archive Note When deleting an image file both images in the image file thermal a...

Page 74: ... delete You can also select the items by touching the screen Selected items are marked with a tick 5 On the right toolbar select the icon and push the navigation pad This displays a dialog box 6 To delete the selected items select Delete and push the navigation pad 13 10 Deleting all files 13 10 1 General You can delete all image and video files from the memory card 13 10 2 Procedure Follow this p...

Page 75: ... the focus ring For more information see section 11 4 Adjusting the infrared camera focus manually page 30 14 2 2 Autofocus You can autofocus the infrared camera by pushing the Autofocus button For more infor mation see section 11 5 Autofocusing the infrared camera page 31 WARNING When the camera is set to autofocusing with the laser method Settings Device settings Focus Auto focus Laser do not po...

Page 76: ... sections 14 3 2 Manual adjustment by touching the screen page 65 and 14 3 3 Manual adjustment by using the navigation pad page 66 In live mode select Temperature scale and then Auto or Manual to en ter automatic or manual image adjustment mode In preview edit mode manual image adjustment mode is active Note You can also assign image adjustment functions to the programmable button For more informa...

Page 77: ...anual image adjustments is enabled disabled by a setting Se lect Settings Device settings User interface options Manual adjustment using touch On Off When manual image adjustment mode is active an adjustment wheel is displayed to the right of the temperature scale Applicable when the manual adjustment by touch function ality is enabled Figure 14 1 Manual adjustment mode active 14 3 2 2 Procedure F...

Page 78: ...e relevant temperatures you will get more details in your area of interest 14 3 2 4 Locking the touch screen When you have adjusted the image to levels that allow you to study your area of interest you can lock the touch screen to prevent further unintentional adjustments To lock the screen touch the icon to the left of the temperature scale To unlock the screen touch the icon to the left of the t...

Page 79: ...de push the navigation pad to display the menu system 2 Select Temperature scale and push the navigation pad This displays a submenu 3 Select Manual and push the navigation pad 4 To simultaneously change the temperature scale minimum and maximum limits push the navigation pad up down 5 To change the minimum limit or the maximum limit do the following Push the navigation pad left right to select hi...

Page 80: ...ion see section 11 12 Assigning functions to the program mable button page 38 14 5 Changing the color palettes 14 5 1 General You can change the color palette that the camera uses to display different temperatures A different palette can make it easier to analyze an image This table explains the different types of color palettes Iron Arctic Rainbow Rainbow high contrast T810190 r AJ 46209 46209 en...

Page 81: ...e 14 6 Changing the measurement parameters For accurate measurements it is important to set the measurement parameters External IR window compensation Object distance Atmospheric temperature Relative humidity Reflected temperature Emissivity You can set the measurement parameters globally You can also change the Emissivity Reflected temperature and Object distance parameters locally for a measurem...

Page 82: ...sequence 14 7 2 Performing an NUC manually 14 7 2 1 Procedure Follow this procedure 1 To perform a manual NUC push and hold down the image archive button for more than 2 seconds Note You can also assign the function Calibrate to the programmable button For more information see section 11 12 Assigning functions to the programmable button page 38 14 8 Hiding all overlay 14 8 1 General The camera ove...

Page 83: ...hidden 14 8 2 Procedure Follow this procedure 1 Push and hold the programmable button This displays the Programmable button menu 2 Push the navigation pad up down to select the function Hide image overlay graphics 3 Push the navigation pad to confirm and exit the menu mode T810190 r AJ 46209 46209 en US 71 ...

Page 84: ...This means that you can edit the image later in the image archive or in FLIR Tools Tools or FLIR Report Studio and select any of the image modes For the Digital camera image mode a digital image with full resolution 5 MP is stored when an image is saved However no thermal information is stored You can choose to turn off the digital camera This can for example be required in re stricted areas and i...

Page 85: ...Working with image modes 15 Image mode Image Thermal Thermal MSX Picture in picture Digital camera T810190 r AJ 46209 46209 en US 73 ...

Page 86: ...Thermal Picture in picture Digital camera Note If the csq video format is selected Settings Save options storage Video compression and the recording mode Video is selected Settings Recording mode it will only be possible to select the image mode Thermal 4 Push the navigation pad to confirm and exit the menu mode 5 If Picture in picture mode is selected you can at this point move and resize the inf...

Page 87: ...No measurements to remove all tools Select Center spot to add a center spot Select Hot spot to add a hot spot detection within a box area Select Cold spot to add a cold spot detection within a box area Select User preset 1 to add user preset 1 Not available in all camera models Select User preset 2 to add user preset 2 Not available in all camera models 4 Push the navigation pad to confirm and exi...

Page 88: ...elect one or more of the following actions depending on the type of tool Remove the tool Resize move center and rotate the tool Set alarms Display maximum minimum average and area values Set local parameters When completed select Done and push the navigation pad 9 When all measurement tools have been added select Save as user preset 10 Push the navigation pad to confirm and exit the menu mode 16 4...

Page 89: ...4 Use the navigation pad to select one of the following Select Resize to change the size of the tool Select Move to move the tool Select Center box circle to center the box or circle tool 5 Push the navigation pad up down and left right to resize or move the tool 6 When completed push the navigation pad and select Done 7 Push the navigation pad to confirm and exit the menu mode 16 5 Changing the m...

Page 90: ...o enter the emissivity by material instead of by value Select Settings Device settings User interface options Emissivity mode Select from materials table Emissivity is the most important measurement parameter to set correctly If the Emissivity is set to a low value the Reflected temperature also becomes important The parameters Object distance Atmospheric temperature and Relative humidity are rele...

Page 91: ...ters for a measurement tool A P next to the measurement tool on the screen indicates that local parameters have been activated for the tool Follow this procedure 1 To select the measurement tool touch the tool on the screen The tool is now dis played with one or more handles 2 Push the navigation pad or touch and hold the tool This displays a context menu 3 Select Use local parameters 4 Push the n...

Page 92: ...about parameters and how to correctly set the emissivity and re flected apparent temperature see section 33 Thermographic measurement techniques page 250 16 6 Displaying values in the result table 16 6 1 General For the box and circle tools you can set the camera to display the maximum minimum average and area values in the result table 16 6 2 Procedure Follow this procedure 1 To select the measur...

Page 93: ...s inactive When the icon with the filled indicator is displayed the function is active 7 When completed push the navigation pad down to close the submenu 8 Select Done and push the navigation pad 16 7 Creating and setting up a difference calculation 16 7 1 General A difference calculation gives the difference between the values of two known measure ment results 16 7 2 Procedure Note You can set up...

Page 94: ...ture is below the preset alarm temperature 16 8 3 Alarm signals When an alarm is set the symbol is displayed in the result table When an alarm is triggered the value in the result table is displayed in red above alarm or blue below alarm and the symbol above alarm or below alarm is blinking You can also set an audible alarm there will be a beep when the alarm is triggered 16 8 4 Procedure There ar...

Page 95: ...playing values in the result table page 80 Follow this procedure 1 To select the measurement tool touch the tool on the screen The tool is now dis played with one or more handles 2 Push the navigation pad or touch and hold the tool This displays a context menu 3 Select Set alarm and push the navigation pad This displays a dialog box 4 In the dialog box you can define the settings for the alarm Ala...

Page 96: ... image in the archive select Measurement 2 Select Select and push the navigation pad This displays a dialog box 3 Select Delta and push the navigation pad This displays a context menu 4 Select Set alarm on delta and push the navigation pad This displays a dialog box 5 In the dialog box you can define the settings for the alarm Alarm condition The condition that triggers the alarm Applicable values...

Page 97: ...his will apply a contrasting color to all pixels with a temperature above the specified temperature level Below alarm This will apply a contrasting color to all pixels with a temperature below the specified temperature level Interval alarm This will apply a contrasting color to all pixels with a temperature be tween two specified temperature levels Condensation alarm Triggers when the camera detec...

Page 98: ...s Follow this procedure 1 Push the navigation pad to display the menu system 2 Select Color and push the navigation pad This displays a submenu 3 Use the navigation pad to select one of the following Above alarm Below alarm Interval alarm 4 Push the navigation pad The threshold temperature is displayed at the top of the screen T810190 r AJ 46209 46209 en US 86 ...

Page 99: ...4 2 About the Insulation alarm The Insulation alarm can detect areas where there may be an insulation deficiency in the building It will trigger when the insulation level which is called the thermal index in the camera falls below a preset value of the energy leakage through a wall Different building codes recommend different values for the insulation level but typical val ues are 60 80 for new bu...

Page 100: ... The relative humidity level at which you want the alarm to be triggered A relative humidity of 100 means that water vapor condenses from the air as liquid water dewpoint A relative humidity of about 70 or above can cause mold For the Insulation alarm the following parameters can be set Indoor temperature The current indoor temperature Outdoor temperature The current outdoor temperature Thermal in...

Page 101: ...ou can also add annotations to a saved image in the image archive Note This section describes the procedures for adding annotations to a saved image in the image archive Adding annotations when saving an image works in a similar way 18 2 Adding a note 18 2 1 General You can add a text note to the image file Using this feature you can annotate images by entering free form text 18 2 2 Procedure Foll...

Page 102: ...eate your own templates For more information see section 18 3 3 Creating a text comment table template page 91 18 3 2 Procedure Follow this procedure 1 Open the image in the image archive 2 Push the navigation pad to display the top toolbar 3 On the top toolbar select the icon and push the navigation pad 4 On the right toolbar select the icon and push the navigation pad This displays a table 5 Opt...

Page 103: ...ools see section 18 3 3 2 Creating a table template using FLIR Tools Tools page 91 Manually creating a text comment file tcf see section 18 3 3 3 Manually creating a table template page 92 18 3 3 2 Creating a table template using FLIR Tools Tools Note If your camera uses an SD card that has been used in another camera FLIR Tools Tools cannot create proper templates for this camera Please clear the...

Page 104: ...ignored 2 Lines that start with and end with are labels and will appear on the left hand side of the table 3 Non empty lines under a label line are regarded as values and will be displayed as op tions to the label above 4 When you save the file select UTF 8 encoding With UTF 8 encoding the file will sup port all languages currently supported by the camera 5 The template will be updated by the came...

Page 105: ...icrophone You can also use a Blue tooth enabled headset For information on how to pair a headset with the camera see section 22 Pairing Bluetooth devices page 101 18 4 2 Procedure Follow this procedure 1 Open the image in the image archive 2 Push the navigation pad to display the top toolbar 3 On the top toolbar select the icon and push the navigation pad 4 On the right toolbar select the icon and...

Page 106: ...tch 18 5 1 General You can add a freehand drawing to an infrared image 18 5 2 Procedure Follow this procedure 1 Open the image in the image archive 2 Push the navigation pad to display the top toolbar 3 On the top toolbar select the icon and push the navigation pad 4 On the right toolbar select the icon and push the navigation pad 5 You are now in sketch mode Draw the sketch by touching the screen...

Page 107: ...se parts of the sketch by touching the screen To add an arrow circle or cross select Stamp sketch and push the navigation pad Select the type of stamp and push the navigation pad The stamp is displayed in the center of the screen You can move the stamp by using the navigation pad or by touching the screen When completed push the navigation pad To clear select Clear all and push the navigation pad ...

Page 108: ... saved image Total number of images Periodic saving will stop when the set number of images have been saved Note If you select the camera will keep on saving images until the memory card is full or until you manually stop the time lapse 5 Push the navigation pad This closes the dialog box 6 Push the back button repeatedly to exit the Settings menu 7 The time interval is displayed at the top of the...

Page 109: ...witch to Thermal image mode 20 2 Procedure Follow this procedure 1 Push the navigation pad to display the menu system 2 Select Settings and push the navigation pad This displays the Settings menu 3 Use the navigation pad to select Recording mode Video 4 Push the back button to exit the Settings menu 5 To start a recording pull and release the trigger A counter at the top of the screen dis plays th...

Page 110: ...clips 20 4 Push the navigation pad to display the top toolbar 5 On the top toolbar select the icon and push the navigation pad 6 To play or pause the video clip push the navigation pad T810190 r AJ 46209 46209 en US 98 ...

Page 111: ...amp laser Disable all 21 2 Procedure Follow this procedure 1 Push the navigation pad to display the menu system 2 Select Settings and push the navigation pad This displays the Settings menu 3 Use the navigation pad to select Recording mode Screening 4 Push the navigation pad This displays a dialog box where you can define the settings for the alarm Allowed deviation The allowed deviation from the ...

Page 112: ... temperature range when you push and hold the button The algorithm has a memory of the last 10 samples It discriminates between the high est and lowest values and calculates an average of the remaining values Do not modify the measurement setup or activate another alarm because this will deac tivate the screening alarm T810190 r AJ 46209 46209 en US 100 ...

Page 113: ...oth device is in visible mode 5 Select Available devices and push the navigation pad 6 Wait until a list of available devices is displayed This will take about 15 seconds 7 When a Bluetooth device is found select the device to add it and begin the pairing procedure The device is then ready to be used Note Only METERLiNK devices FLIR meters and Bluetooth enabled headsets will appear in the list of ...

Page 114: ...ad To change the SSID select Network name SSID and push the navigation pad To change the WPA2 password select Password and push the navigation pad Note These parameters are set for your camera s network They will be used by the external device to connect that device to the network 23 3 Connecting the camera to a WLAN less common use Follow this procedure 1 Push the navigation pad to display the me...

Page 115: ...u can add more than one value from the same FLIR meter The last added value is displayed below the previous val ues The live value is displayed with a dotted outline If the screen display for values is full it is still possible to add more values from the FLIR meter Added values are then indicated by a box with a number that counts up each time a new value is added To find out whether a FLIR meter...

Page 116: ...the value currently displayed by the FLIR meter Push and hold the programmable button to remove all FLIR meter values from the image Note Any function assigned to the programmable button is temporarily disabled when in preview mode or when editing an image in the archive 24 4 Typical moisture measurement and documentation procedure 24 4 1 General The following procedure can form the basis for othe...

Page 117: ...Fetching data from external FLIR meters 24 24 5 More information For more information see the user manuals that are shipped with FLIR meters T810190 r AJ 46209 46209 en US 105 ...

Page 118: ...section 19 Programming the camera time lapse page 96 Screening This setting enables screening mode For more information see section 21 Screening alarm page 99 25 1 2 Connections Wi Fi This setting defines Wi Fi networks For more information see section 23 Config uring Wi Fi page 102 Bluetooth This setting defines Bluetooth connectivity For more information see sec tion 22 Pairing Bluetooth devices...

Page 119: ...G file Digital camera This setting is used to turn on off the digital camera Turning off the digi tal camera can for example be required in restricted areas and in confidential e g doc tor patient situations When the digital camera is off the images modes Thermal MSX and Picture in picture are disabled Measure distance This setting defines if the laser distance meter will be used to meas ure the d...

Page 120: ...is setting specifies what image information the camera will display as an overlay on the image For more information see section 9 5 Image overlay information page 25 You can select the following information to display Compass Date time Emissivity Reflected temperature Distance Relative humidity Atmospheric temperature Note This setting only specifies what information to overlay on the image All im...

Page 121: ... default camera mode This setting will affect the image mode color palette measurement tools and measurement parameters Saved images will not be affected Reset device settings to factory default This setting will affect all camera settings including regional settings Saved images will not be affected The camera will be re started and you will be prompted to set the regional settings Reset image co...

Page 122: ...propyl alcohol 96 ethyl alcohol C2H5OH 26 2 2 Equipment Cotton wool CAUTION If you use a lens cleaning cloth it must be dry Do not use a lens cleaning cloth with the liquids that are giv en in section 26 2 1 above These liquids can cause material on the lens cleaning cloth to become loose This material can have an unwanted effect on the surface of the lens 26 2 3 Procedure Follow this procedure 1 ...

Page 123: ...on only applies to cameras where removing the lens exposes the infrared detector In some cases the dust cannot be removed by following this procedure the infrared de tector must be cleaned mechanically This mechanical cleaning must be carried out by an authorized service partner CAUTION In Step 2 below do not use pressurized air from pneumatic air circuits in a workshop etc as this air usu ally co...

Page 124: ...5 42 14 209 27 19 FLIR E95 24 14 215 27 20 FLIR E95 24 42 222 27 21 FLIR E95 24 14 42 229 27 1 Online field of view calculator Please visit http support flir com and click the photo of the camera series for field of view tables for all lens camera combinations 27 2 Note about technical data FLIR Systems reserves the right to change specifications at any time without prior notice Please check http ...

Page 125: ...24 1 0 m 3 28 ft 14 Focal length 10 mm 0 39 in 42 17 mm 0 67 in 24 29 mm 1 41 in 14 Spatial resolution IFOV 2 41 mrad pixel 42 1 31 mrad pixel 24 0 75 mrad pixel 14 Additional lenses 42 14 Lens identification Automatic f number 1 1 42 1 3 24 1 5 14 Image frequency 30 Hz Focus Continuous LDM One shot LDM One shot contrast Manual Field of view match Yes Digital zoom 1 4 continuous Detector data Foca...

Page 126: ... Yes Measurement Object temperature range 20 to 120 C 4 to 248 F 0 650 C 32 1200 F Optional 300 1000 C 572 1830 F Accuracy 2 C 3 6 F or 2 of reading for ambient tem perature 15 35 C 59 95 F and object tempera ture above 0 C 32 F Measurement analysis Spotmeter 1 in live mode Area 1 in live mode Automatic hot cold detection Auto maximum minimum markers within area Measurement presets No measurements...

Page 127: ...able memory SD card 8 GB Time lapse periodic image storage No Remote control operation Using FLIR Tools using USB cable FLIR Tools Mobile over Wi Fi Image file format Standard JPEG measurement data included In frared only mode Image annotations Voice 60 seconds built in microphone and speaker and via Bluetooth on still images and video Text Text from predefined list or soft keyboard on touchscreen...

Page 128: ...n Laser Class 2 0 05 40 m 1 6 131 ft 1 of measured distance Data communication interfaces Interfaces USB 2 0 Bluetooth Wi Fi DisplayPort METERLiNK Bluetooth Communication with headset and external sensors Wi Fi Peer to peer ad hoc or infrastructure network Audio Microphone and speaker for voice annotation of images USB USB Type C data transfer video power USB standard USB 2 0 High Speed Video out ...

Page 129: ...1 489 1 radio ETSI EN 301 489 17 EN 61000 6 2 immunity EN 61000 6 3 emission FCC 47 CFR Part 15 Class B emission Radio spectrum ETSI EN 300 328 FCC Part 15 249 RSS 247 Issue 2 Encapsulation IP 54 IEC 60529 Shock 25g IEC 60068 2 27 Vibration 2g IEC 60068 2 6 Drop Designed for 2 m 6 6 ft Safety EN UL CSA PSE 60950 1 Physical data Weight including battery 1 kg 2 2 lb Size L W H 278 4 116 1 113 1 mm 1...

Page 130: ...with lens Lens cap front Lens cap front and rear only for extra lenses Packaging weight Packaging size 500 190 370 mm 19 7 7 5 14 6 in EAN 13 4743254002654 UPC 12 845188013882 Country of origin Estonia Supplies accessories T197771ACC Bluetooth Headset T199425ACC Battery charger T199588 Lens 14 case T199590 Lens 42 case T199589 Lens 24 case T911705ACC USB Type C to USB Type C cable USB 2 0 standard...

Page 131: ...Technical data 27 T199013 FLIR ResearchIR Max 4 printed license key T199043 FLIR ResearchIR Max 4 Upgrade printed license key T810190 r AJ 46209 46209 en US 119 ...

Page 132: ...24 1 0 m 3 28 ft 14 Focal length 10 mm 0 39 in 42 17 mm 0 67 in 24 29 mm 1 41 in 14 Spatial resolution IFOV 2 41 mrad pixel 42 1 31 mrad pixel 24 0 75 mrad pixel 14 Additional lenses 42 14 Lens identification Automatic f number 1 1 42 1 3 24 1 5 14 Image frequency 30 Hz Focus Continuous LDM One shot LDM One shot contrast Manual Field of view match Yes Digital zoom 1 4 continuous Detector data Foca...

Page 133: ... Yes Measurement Object temperature range 20 to 120 C 4 to 248 F 0 650 C 32 1200 F Optional 300 1000 C 572 1830 F Accuracy 2 C 3 6 F or 2 of reading for ambient tem perature 15 35 C 59 95 F and object tempera ture above 0 C 32 F Measurement analysis Spotmeter 1 in live mode Area 1 in live mode Automatic hot cold detection Auto maximum minimum markers within area Measurement presets No measurements...

Page 134: ...able memory SD card 8 GB Time lapse periodic image storage No Remote control operation Using FLIR Tools using USB cable FLIR Tools Mobile over Wi Fi Image file format Standard JPEG measurement data included In frared only mode Image annotations Voice 60 seconds built in microphone and speaker and via Bluetooth on still images and video Text Text from predefined list or soft keyboard on touchscreen...

Page 135: ...n Laser Class 2 0 05 40 m 1 6 131 ft 1 of measured distance Data communication interfaces Interfaces USB 2 0 Bluetooth Wi Fi DisplayPort METERLiNK Bluetooth Communication with headset and external sensors Wi Fi Peer to peer ad hoc or infrastructure network Audio Microphone and speaker for voice annotation of images USB USB Type C data transfer video power USB standard USB 2 0 High Speed Video out ...

Page 136: ...1 489 1 radio ETSI EN 301 489 17 EN 61000 6 2 immunity EN 61000 6 3 emission FCC 47 CFR Part 15 Class B emission Radio spectrum ETSI EN 300 328 FCC Part 15 249 RSS 247 Issue 2 Encapsulation IP 54 IEC 60529 Shock 25g IEC 60068 2 27 Vibration 2g IEC 60068 2 6 Drop Designed for 2 m 6 6 ft Safety EN UL CSA PSE 60950 1 Physical data Weight including battery 1 kg 2 2 lb Size L W H 278 4 116 1 113 1 mm 1...

Page 137: ...with lens Lens cap front Lens cap front and rear only for extra lenses Packaging weight Packaging size 500 190 370 mm 19 7 7 5 14 6 in EAN 13 4743254002661 UPC 12 845188013899 Country of origin Estonia Supplies accessories T197771ACC Bluetooth Headset T199425ACC Battery charger T199588 Lens 14 case T199590 Lens 42 case T199589 Lens 24 case T911705ACC USB Type C to USB Type C cable USB 2 0 standard...

Page 138: ...Technical data 27 T199013 FLIR ResearchIR Max 4 printed license key T199043 FLIR ResearchIR Max 4 Upgrade printed license key T810190 r AJ 46209 46209 en US 126 ...

Page 139: ... 24 1 0 m 3 28 ft 14 Focal length 10 mm 0 39 in 42 17 mm 0 67 in 24 29 mm 1 41 in 14 Spatial resolution IFOV 2 41 mrad pixel 42 1 31 mrad pixel 24 0 75 mrad pixel 14 Additional lenses 42 14 Lens identification Automatic f number 1 1 42 1 3 24 1 5 14 Image frequency 30 Hz Focus Continuous LDM One shot LDM One shot contrast Manual Field of view match Yes Digital zoom 1 4 continuous Detector data Foc...

Page 140: ... Yes Measurement Object temperature range 20 to 120 C 4 to 248 F 0 650 C 32 1200 F Optional 300 1000 C 572 1830 F Accuracy 2 C 3 6 F or 2 of reading for ambient tem perature 15 35 C 59 95 F and object tempera ture above 0 C 32 F Measurement analysis Spotmeter 1 in live mode Area 1 in live mode Automatic hot cold detection Auto maximum minimum markers within area Measurement presets No measurements...

Page 141: ...able memory SD card 8 GB Time lapse periodic image storage No Remote control operation Using FLIR Tools using USB cable FLIR Tools Mobile over Wi Fi Image file format Standard JPEG measurement data included In frared only mode Image annotations Voice 60 seconds built in microphone and speaker and via Bluetooth on still images and video Text Text from predefined list or soft keyboard on touchscreen...

Page 142: ...n Laser Class 2 0 05 40 m 1 6 131 ft 1 of measured distance Data communication interfaces Interfaces USB 2 0 Bluetooth Wi Fi DisplayPort METERLiNK Bluetooth Communication with headset and external sensors Wi Fi Peer to peer ad hoc or infrastructure network Audio Microphone and speaker for voice annotation of images USB USB Type C data transfer video power USB standard USB 2 0 High Speed Video out ...

Page 143: ...1 489 1 radio ETSI EN 301 489 17 EN 61000 6 2 immunity EN 61000 6 3 emission FCC 47 CFR Part 15 Class B emission Radio spectrum ETSI EN 300 328 FCC Part 15 249 RSS 247 Issue 2 Encapsulation IP 54 IEC 60529 Shock 25g IEC 60068 2 27 Vibration 2g IEC 60068 2 6 Drop Designed for 2 m 6 6 ft Safety EN UL CSA PSE 60950 1 Physical data Weight including battery 1 kg 2 2 lb Size L W H 278 4 116 1 113 1 mm 1...

Page 144: ... Hard transport case Infrared camera with lens Lens cap front Lens cap front and rear only for extra lenses Packaging weight Packaging size 500 190 370 mm 19 7 7 5 14 6 in EAN 13 4743254003323 UPC 12 845188014735 Country of origin Estonia Supplies accessories T197771ACC Bluetooth Headset T911705ACC USB Type C to USB Type C cable USB 2 0 standard 1 0 m T911632ACC USB Type C to HDMI adapter standard...

Page 145: ... 24 1 0 m 3 28 ft 14 Focal length 10 mm 0 39 in 42 17 mm 0 67 in 24 29 mm 1 41 in 14 Spatial resolution IFOV 2 41 mrad pixel 42 1 31 mrad pixel 24 0 75 mrad pixel 14 Additional lenses 42 14 Lens identification Automatic f number 1 1 42 1 3 24 1 5 14 Image frequency 30 Hz Focus Continuous LDM One shot LDM One shot contrast Manual Field of view match Yes Digital zoom 1 4 continuous Detector data Foc...

Page 146: ... Yes Measurement Object temperature range 20 to 120 C 4 to 248 F 0 650 C 32 1200 F Optional 300 1000 C 572 1830 F Accuracy 2 C 3 6 F or 2 of reading for ambient tem perature 15 35 C 59 95 F and object tempera ture above 0 C 32 F Measurement analysis Spotmeter 1 in live mode Area 1 in live mode Automatic hot cold detection Auto maximum minimum markers within area Measurement presets No measurements...

Page 147: ...able memory SD card 8 GB Time lapse periodic image storage No Remote control operation Using FLIR Tools using USB cable FLIR Tools Mobile over Wi Fi Image file format Standard JPEG measurement data included In frared only mode Image annotations Voice 60 seconds built in microphone and speaker and via Bluetooth on still images and video Text Text from predefined list or soft keyboard on touchscreen...

Page 148: ...n Laser Class 2 0 05 40 m 1 6 131 ft 1 of measured distance Data communication interfaces Interfaces USB 2 0 Bluetooth Wi Fi DisplayPort METERLiNK Bluetooth Communication with headset and external sensors Wi Fi Peer to peer ad hoc or infrastructure network Audio Microphone and speaker for voice annotation of images USB USB Type C data transfer video power USB standard USB 2 0 High Speed Video out ...

Page 149: ...1 489 1 radio ETSI EN 301 489 17 EN 61000 6 2 immunity EN 61000 6 3 emission FCC 47 CFR Part 15 Class B emission Radio spectrum ETSI EN 300 328 FCC Part 15 249 RSS 247 Issue 2 Encapsulation IP 54 IEC 60529 Shock 25g IEC 60068 2 27 Vibration 2g IEC 60068 2 6 Drop Designed for 2 m 6 6 ft Safety EN UL CSA PSE 60950 1 Physical data Weight including battery 1 kg 2 2 lb Size L W H 278 4 116 1 113 1 mm 1...

Page 150: ...ansport case Infrared camera with lens Lens cap front Lens cap front and rear only for extra lenses Packaging weight Packaging size 500 190 370 mm 19 7 7 5 14 6 in EAN 13 4743254002739 UPC 12 845188013981 Country of origin Estonia Supplies and accessories T197771ACC Bluetooth Headset T199425ACC Battery charger T199588 Lens 14 case T199590 Lens 42 case T199589 Lens 24 case T911705ACC USB Type C to ...

Page 151: ...hnical data 27 T198696 FLIR ResearchIR Max 4 hardware sec dev T199013 FLIR ResearchIR Max 4 printed license key T199043 FLIR ResearchIR Max 4 Upgrade printed license key T810190 r AJ 46209 46209 en US 139 ...

Page 152: ...m 3 28 ft 14 Focal length 10 mm 0 39 in 42 17 mm 0 67 in 24 29 mm 1 41 in 14 Spatial resolution IFOV 2 41 mrad pixel 42 1 31 mrad pixel 24 0 75 mrad pixel 14 Additional lenses 42 14 Lens identification Automatic f number 1 4 Image frequency 30 Hz Focus Continuous LDM One shot LDM One shot contrast Manual Field of view match Yes Digital zoom 1 4 continuous Detector data Focal plane array spectral r...

Page 153: ... 650 C 32 1200 F Optional 300 1000 C 572 1830 F Accuracy 2 C 3 6 F or 2 of reading for ambient tem perature 15 35 C 59 95 F and object tempera ture above 0 C 32 F Measurement analysis Spotmeter 1 in live mode Area 1 in live mode Automatic hot cold detection Auto maximum minimum markers within area Measurement presets No measurements Center spot Hot spot Cold spot User preset 1 User preset 2 Differ...

Page 154: ...No Remote control operation Using FLIR Tools using USB cable FLIR Tools Mobile over Wi Fi Image file format Standard JPEG measurement data included In frared only mode Image annotations Voice 60 seconds built in microphone and speaker and via Bluetooth on still images and video Text Text from predefined list or soft keyboard on touchscreen Visual image annotation Yes Image sketch Yes on infrared i...

Page 155: ...n Laser Class 2 0 05 40 m 1 6 131 ft 1 of measured distance Data communication interfaces Interfaces USB 2 0 Bluetooth Wi Fi DisplayPort METERLiNK Bluetooth Communication with headset and external sensors Wi Fi Peer to peer ad hoc or infrastructure network Audio Microphone and speaker for voice annotation of images USB USB Type C data transfer video power USB standard USB 2 0 High Speed Video out ...

Page 156: ...1 489 1 radio ETSI EN 301 489 17 EN 61000 6 2 immunity EN 61000 6 3 emission FCC 47 CFR Part 15 Class B emission Radio spectrum ETSI EN 300 328 FCC Part 15 249 RSS 247 Issue 2 Encapsulation IP 54 IEC 60529 Shock 25g IEC 60068 2 27 Vibration 2g IEC 60068 2 6 Drop Designed for 2 m 6 6 ft Safety EN UL CSA PSE 60950 1 Physical data Weight including battery 1 kg 2 2 lb Size L W H 278 4 116 1 113 1 mm 1...

Page 157: ...transport case Infrared camera with lens Lens cap front Lens cap front and rear only for extra lenses Packaging weight Packaging size 500 190 370 mm 19 7 7 5 14 6 in EAN 13 4743254002746 UPC 12 845188013998 Country of origin Estonia Supplies accessories T197771ACC Bluetooth Headset T199425ACC Battery charger T199588 Lens 14 case T199590 Lens 42 case T199589 Lens 24 case T911705ACC USB Type C to US...

Page 158: ...hnical data 27 T198696 FLIR ResearchIR Max 4 hardware sec dev T199013 FLIR ResearchIR Max 4 printed license key T199043 FLIR ResearchIR Max 4 Upgrade printed license key T810190 r AJ 46209 46209 en US 146 ...

Page 159: ...ft 24 1 0 m 3 28 ft 14 Focal length 10 mm 0 39 in 42 17 mm 0 67 in 24 29 mm 1 41 in 14 Spatial resolution IFOV 2 41 mrad pixel 42 1 31 mrad pixel 24 0 75 mrad pixel 14 Additional lenses 42 14 Lens identification Automatic f number 1 1 42 1 3 24 1 5 14 Image frequency 30 Hz Focus Continuous LDM One shot LDM One shot contrast Manual Field of view match Yes Digital zoom 1 4 continuous Detector data F...

Page 160: ... Yes Measurement Object temperature range 20 to 120 C 4 to 248 F 0 650 C 32 1200 F Optional 300 1000 C 572 1830 F Accuracy 2 C 3 6 F or 2 of reading for ambient tem perature 15 35 C 59 95 F and object tempera ture above 0 C 32 F Measurement analysis Spotmeter 1 in live mode Area 1 in live mode Automatic hot cold detection Auto maximum minimum markers within area Measurement presets No measurements...

Page 161: ...able memory SD card 8 GB Time lapse periodic image storage No Remote control operation Using FLIR Tools using USB cable FLIR Tools Mobile over Wi Fi Image file format Standard JPEG measurement data included In frared only mode Image annotations Voice 60 seconds built in microphone and speaker and via Bluetooth on still images and video Text Text from predefined list or soft keyboard on touchscreen...

Page 162: ...n Laser Class 2 0 05 40 m 1 6 131 ft 1 of measured distance Data communication interfaces Interfaces USB 2 0 Bluetooth Wi Fi DisplayPort METERLiNK Bluetooth Communication with headset and external sensors Wi Fi Peer to peer ad hoc or infrastructure network Audio Microphone and speaker for voice annotation of images USB USB Type C data transfer video power USB standard USB 2 0 High Speed Video out ...

Page 163: ...1 489 1 radio ETSI EN 301 489 17 EN 61000 6 2 immunity EN 61000 6 3 emission FCC 47 CFR Part 15 Class B emission Radio spectrum ETSI EN 300 328 FCC Part 15 249 RSS 247 Issue 2 Encapsulation IP 54 IEC 60529 Shock 25g IEC 60068 2 27 Vibration 2g IEC 60068 2 6 Drop Designed for 2 m 6 6 ft Safety EN UL CSA PSE 60950 1 Physical data Weight including battery 1 kg 2 2 lb Size L W H 278 4 116 1 113 1 mm 1...

Page 164: ...ra lens 14 Extra lens 42 Hard transport case Infrared camera with lens Lens cap front Lens cap front and rear only for extra lenses Packaging weight Packaging size 500 190 370 mm 19 7 7 5 14 6 in EAN 13 4743254002753 UPC 12 845188014001 Country of origin Estonia Supplies and accessories T197771ACC Bluetooth Headset T199425ACC Battery charger T199588 Lens 14 case T199590 Lens 42 case T199589 Lens 2...

Page 165: ...IR Tools download card incl license key T198696 FLIR ResearchIR Max 4 hardware sec dev T199013 FLIR ResearchIR Max 4 printed license key T199043 FLIR ResearchIR Max 4 Upgrade printed license key T810190 r AJ 46209 46209 en US 153 ...

Page 166: ...24 1 0 m 3 28 ft 14 Focal length 10 mm 0 39 in 42 17 mm 0 67 in 24 29 mm 1 41 in 14 Spatial resolution IFOV 2 00 mrad pixel 42 1 09 mrad pixel 24 0 63 mrad pixel 14 Additional lenses 42 14 Lens identification Automatic f number 1 1 42 1 3 24 1 5 14 Image frequency 30 Hz Focus Continuous LDM One shot LDM One shot contrast Manual Field of view match Yes Digital zoom 1 4 continuous Detector data Foca...

Page 167: ...ry Yes Measurement Object temperature range 20 to 120 C 4 to 248 F 0 650 C 32 1200 F 300 C to 1200 C 572 2192 F Accuracy 2 C 3 6 F or 2 of reading for ambient tem perature 15 35 C 59 95 F and object tempera ture above 0 C 32 F Measurement analysis Spotmeter 3 in live mode Area 3 in live mode Automatic hot cold detection Auto maximum minimum markers within area Measurement presets No measurements C...

Page 168: ...ble memory SD card 8 GB Time lapse periodic image storage No Remote control operation Using FLIR Tools using USB cable FLIR Tools Mobile over Wi Fi Image file format Standard JPEG measurement data included In frared only mode Image annotations Voice 60 seconds built in microphone and speaker and via Bluetooth on still images and video Text Text from predefined list or soft keyboard on touchscreen ...

Page 169: ...n Laser Class 2 0 05 40 m 1 6 131 ft 1 of measured distance Data communication interfaces Interfaces USB 2 0 Bluetooth Wi Fi DisplayPort METERLiNK Bluetooth Communication with headset and external sensors Wi Fi Peer to peer ad hoc or infrastructure network Audio Microphone and speaker for voice annotation of images USB USB Type C data transfer video power USB standard USB 2 0 High Speed Video out ...

Page 170: ...1 489 1 radio ETSI EN 301 489 17 EN 61000 6 2 immunity EN 61000 6 3 emission FCC 47 CFR Part 15 Class B emission Radio spectrum ETSI EN 300 328 FCC Part 15 249 RSS 247 Issue 2 Encapsulation IP 54 IEC 60529 Shock 25g IEC 60068 2 27 Vibration 2g IEC 60068 2 6 Drop Designed for 2 m 6 6 ft Safety EN UL CSA PSE 60950 1 Physical data Weight including battery 1 kg 2 2 lb Size L W H 278 4 116 1 113 1 mm 1...

Page 171: ...th lens Lens cap front Lens cap front and rear only for extra lenses Packaging weight Packaging size 500 190 370 mm 19 7 7 5 14 6 in EAN 13 4743254002678 UPC 12 845188013905 Country of origin Estonia Supplies accessories T197771ACC Bluetooth Headset T199425ACC Battery charger T199588 Lens 14 case T199590 Lens 42 case T199589 Lens 24 case T911705ACC USB Type C to USB Type C cable USB 2 0 standard 1...

Page 172: ...Technical data 27 T199043 FLIR ResearchIR Max 4 Upgrade printed license key T810190 r AJ 46209 46209 en US 160 ...

Page 173: ...24 1 0 m 3 28 ft 14 Focal length 10 mm 0 39 in 42 17 mm 0 67 in 24 29 mm 1 41 in 14 Spatial resolution IFOV 2 00 mrad pixel 42 1 09 mrad pixel 24 0 63 mrad pixel 14 Additional lenses 42 14 Lens identification Automatic f number 1 1 42 1 3 24 1 5 14 Image frequency 30 Hz Focus Continuous LDM One shot LDM One shot contrast Manual Field of view match Yes Digital zoom 1 4 continuous Detector data Foca...

Page 174: ...ry Yes Measurement Object temperature range 20 to 120 C 4 to 248 F 0 650 C 32 1200 F 300 C to 1200 C 572 2192 F Accuracy 2 C 3 6 F or 2 of reading for ambient tem perature 15 35 C 59 95 F and object tempera ture above 0 C 32 F Measurement analysis Spotmeter 3 in live mode Area 3 in live mode Automatic hot cold detection Auto maximum minimum markers within area Measurement presets No measurements C...

Page 175: ...ble memory SD card 8 GB Time lapse periodic image storage No Remote control operation Using FLIR Tools using USB cable FLIR Tools Mobile over Wi Fi Image file format Standard JPEG measurement data included In frared only mode Image annotations Voice 60 seconds built in microphone and speaker and via Bluetooth on still images and video Text Text from predefined list or soft keyboard on touchscreen ...

Page 176: ...n Laser Class 2 0 05 40 m 1 6 131 ft 1 of measured distance Data communication interfaces Interfaces USB 2 0 Bluetooth Wi Fi DisplayPort METERLiNK Bluetooth Communication with headset and external sensors Wi Fi Peer to peer ad hoc or infrastructure network Audio Microphone and speaker for voice annotation of images USB USB Type C data transfer video power USB standard USB 2 0 High Speed Video out ...

Page 177: ...1 489 1 radio ETSI EN 301 489 17 EN 61000 6 2 immunity EN 61000 6 3 emission FCC 47 CFR Part 15 Class B emission Radio spectrum ETSI EN 300 328 FCC Part 15 249 RSS 247 Issue 2 Encapsulation IP 54 IEC 60529 Shock 25g IEC 60068 2 27 Vibration 2g IEC 60068 2 6 Drop Designed for 2 m 6 6 ft Safety EN UL CSA PSE 60950 1 Physical data Weight including battery 1 kg 2 2 lb Size L W H 278 4 116 1 113 1 mm 1...

Page 178: ...th lens Lens cap front Lens cap front and rear only for extra lenses Packaging weight Packaging size 500 190 370 mm 19 7 7 5 14 6 in EAN 13 4743254002685 UPC 12 845188013912 Country of origin Estonia Supplies accessories T197771ACC Bluetooth Headset T199425ACC Battery charger T199588 Lens 14 case T199590 Lens 42 case T199589 Lens 24 case T911705ACC USB Type C to USB Type C cable USB 2 0 standard 1...

Page 179: ...Technical data 27 T199043 FLIR ResearchIR Max 4 Upgrade printed license key T810190 r AJ 46209 46209 en US 167 ...

Page 180: ...t 24 1 0 m 3 28 ft 14 Focal length 10 mm 0 39 in 42 17 mm 0 67 in 24 29 mm 1 41 in 14 Spatial resolution IFOV 2 00 mrad pixel 42 1 09 mrad pixel 24 0 63 mrad pixel 14 Additional lenses 42 14 Lens identification Automatic f number 1 1 42 1 3 24 1 5 14 Image frequency 30 Hz Focus Continuous LDM One shot LDM One shot contrast Manual Field of view match Yes Digital zoom 1 4 continuous Detector data Fo...

Page 181: ...ry Yes Measurement Object temperature range 20 to 120 C 4 to 248 F 0 650 C 32 1200 F 300 C to 1200 C 572 2192 F Accuracy 2 C 3 6 F or 2 of reading for ambient tem perature 15 35 C 59 95 F and object tempera ture above 0 C 32 F Measurement analysis Spotmeter 3 in live mode Area 3 in live mode Automatic hot cold detection Auto maximum minimum markers within area Measurement presets No measurements C...

Page 182: ...ble memory SD card 8 GB Time lapse periodic image storage No Remote control operation Using FLIR Tools using USB cable FLIR Tools Mobile over Wi Fi Image file format Standard JPEG measurement data included In frared only mode Image annotations Voice 60 seconds built in microphone and speaker and via Bluetooth on still images and video Text Text from predefined list or soft keyboard on touchscreen ...

Page 183: ...n Laser Class 2 0 05 40 m 1 6 131 ft 1 of measured distance Data communication interfaces Interfaces USB 2 0 Bluetooth Wi Fi DisplayPort METERLiNK Bluetooth Communication with headset and external sensors Wi Fi Peer to peer ad hoc or infrastructure network Audio Microphone and speaker for voice annotation of images USB USB Type C data transfer video power USB standard USB 2 0 High Speed Video out ...

Page 184: ...1 489 1 radio ETSI EN 301 489 17 EN 61000 6 2 immunity EN 61000 6 3 emission FCC 47 CFR Part 15 Class B emission Radio spectrum ETSI EN 300 328 FCC Part 15 249 RSS 247 Issue 2 Encapsulation IP 54 IEC 60529 Shock 25g IEC 60068 2 27 Vibration 2g IEC 60068 2 6 Drop Designed for 2 m 6 6 ft Safety EN UL CSA PSE 60950 1 Physical data Weight including battery 1 kg 2 2 lb Size L W H 278 4 116 1 113 1 mm 1...

Page 185: ...y charger Extra lens 14 Hard transport case Infrared camera with lens Lens cap front Lens cap front and rear only for extra lenses Packaging weight Packaging size 500 190 370 mm 19 7 7 5 14 6 in EAN 13 4743254003330 UPC 12 845188014742 Country of origin Estonia Supplies accessories T197771ACC Bluetooth Headset T911705ACC USB Type C to USB Type C cable USB 2 0 standard 1 0 m T911632ACC USB Type C t...

Page 186: ...t 24 1 0 m 3 28 ft 14 Focal length 10 mm 0 39 in 42 17 mm 0 67 in 24 29 mm 1 41 in 14 Spatial resolution IFOV 2 00 mrad pixel 42 1 09 mrad pixel 24 0 63 mrad pixel 14 Additional lenses 42 14 Lens identification Automatic f number 1 1 42 1 3 24 1 5 14 Image frequency 30 Hz Focus Continuous LDM One shot LDM One shot contrast Manual Field of view match Yes Digital zoom 1 4 continuous Detector data Fo...

Page 187: ...ry Yes Measurement Object temperature range 20 to 120 C 4 to 248 F 0 650 C 32 1200 F 300 C to 1200 C 572 2192 F Accuracy 2 C 3 6 F or 2 of reading for ambient tem perature 15 35 C 59 95 F and object tempera ture above 0 C 32 F Measurement analysis Spotmeter 3 in live mode Area 3 in live mode Automatic hot cold detection Auto maximum minimum markers within area Measurement presets No measurements C...

Page 188: ...ble memory SD card 8 GB Time lapse periodic image storage No Remote control operation Using FLIR Tools using USB cable FLIR Tools Mobile over Wi Fi Image file format Standard JPEG measurement data included In frared only mode Image annotations Voice 60 seconds built in microphone and speaker and via Bluetooth on still images and video Text Text from predefined list or soft keyboard on touchscreen ...

Page 189: ...n Laser Class 2 0 05 40 m 1 6 131 ft 1 of measured distance Data communication interfaces Interfaces USB 2 0 Bluetooth Wi Fi DisplayPort METERLiNK Bluetooth Communication with headset and external sensors Wi Fi Peer to peer ad hoc or infrastructure network Audio Microphone and speaker for voice annotation of images USB USB Type C data transfer video power USB standard USB 2 0 High Speed Video out ...

Page 190: ...1 489 1 radio ETSI EN 301 489 17 EN 61000 6 2 immunity EN 61000 6 3 emission FCC 47 CFR Part 15 Class B emission Radio spectrum ETSI EN 300 328 FCC Part 15 249 RSS 247 Issue 2 Encapsulation IP 54 IEC 60529 Shock 25g IEC 60068 2 27 Vibration 2g IEC 60068 2 6 Drop Designed for 2 m 6 6 ft Safety EN UL CSA PSE 60950 1 Physical data Weight including battery 1 kg 2 2 lb Size L W H 278 4 116 1 113 1 mm 1...

Page 191: ...nsport case Infrared camera with lens Lens cap front Lens cap front and rear only for extra lenses Packaging weight Packaging size 500 190 370 mm 19 7 7 5 14 6 in EAN 13 4743254002777 UPC 12 845188014025 Country of origin Estonia Supplies and accessories T197771ACC Bluetooth Headset T199425ACC Battery charger T199588 Lens 14 case T199590 Lens 42 case T199589 Lens 24 case T911705ACC USB Type C to U...

Page 192: ...Technical data 27 T199013 FLIR ResearchIR Max 4 printed license key T199043 FLIR ResearchIR Max 4 Upgrade printed license key T810190 r AJ 46209 46209 en US 180 ...

Page 193: ...t 24 1 0 m 3 28 ft 14 Focal length 10 mm 0 39 in 42 17 mm 0 67 in 24 29 mm 1 41 in 14 Spatial resolution IFOV 2 00 mrad pixel 42 1 09 mrad pixel 24 0 63 mrad pixel 14 Additional lenses 42 14 Lens identification Automatic f number 1 1 42 1 3 24 1 5 14 Image frequency 30 Hz Focus Continuous LDM One shot LDM One shot contrast Manual Field of view match Yes Digital zoom 1 4 continuous Detector data Fo...

Page 194: ...ry Yes Measurement Object temperature range 20 to 120 C 4 to 248 F 0 650 C 32 1200 F 300 C to 1200 C 572 2192 F Accuracy 2 C 3 6 F or 2 of reading for ambient tem perature 15 35 C 59 95 F and object tempera ture above 0 C 32 F Measurement analysis Spotmeter 3 in live mode Area 3 in live mode Automatic hot cold detection Auto maximum minimum markers within area Measurement presets No measurements C...

Page 195: ...ble memory SD card 8 GB Time lapse periodic image storage No Remote control operation Using FLIR Tools using USB cable FLIR Tools Mobile over Wi Fi Image file format Standard JPEG measurement data included In frared only mode Image annotations Voice 60 seconds built in microphone and speaker and via Bluetooth on still images and video Text Text from predefined list or soft keyboard on touchscreen ...

Page 196: ...n Laser Class 2 0 05 40 m 1 6 131 ft 1 of measured distance Data communication interfaces Interfaces USB 2 0 Bluetooth Wi Fi DisplayPort METERLiNK Bluetooth Communication with headset and external sensors Wi Fi Peer to peer ad hoc or infrastructure network Audio Microphone and speaker for voice annotation of images USB USB Type C data transfer video power USB standard USB 2 0 High Speed Video out ...

Page 197: ...1 489 1 radio ETSI EN 301 489 17 EN 61000 6 2 immunity EN 61000 6 3 emission FCC 47 CFR Part 15 Class B emission Radio spectrum ETSI EN 300 328 FCC Part 15 249 RSS 247 Issue 2 Encapsulation IP 54 IEC 60529 Shock 25g IEC 60068 2 27 Vibration 2g IEC 60068 2 6 Drop Designed for 2 m 6 6 ft Safety EN UL CSA PSE 60950 1 Physical data Weight including battery 1 kg 2 2 lb Size L W H 278 4 116 1 113 1 mm 1...

Page 198: ...ransport case Infrared camera with lens Lens cap front Lens cap front and rear only for extra lenses Packaging weight Packaging size 500 190 370 mm 19 7 7 5 14 6 in EAN 13 4743254002784 UPC 12 845188014032 Country of origin Estonia Supplies accessories T197771ACC Bluetooth Headset T199425ACC Battery charger T199588 Lens 14 case T199590 Lens 42 case T199589 Lens 24 case T911705ACC USB Type C to USB...

Page 199: ...Technical data 27 T199013 FLIR ResearchIR Max 4 printed license key T199043 FLIR ResearchIR Max 4 Upgrade printed license key T810190 r AJ 46209 46209 en US 187 ...

Page 200: ...ft 24 1 0 m 3 28 ft 14 Focal length 10 mm 0 39 in 42 17 mm 0 67 in 24 29 mm 1 41 in 14 Spatial resolution IFOV 2 00 mrad pixel 42 1 09 mrad pixel 24 0 63 mrad pixel 14 Additional lenses 42 14 Lens identification Automatic f number 1 1 42 1 3 24 1 5 14 Image frequency 30 Hz Focus Continuous LDM One shot LDM One shot contrast Manual Field of view match Yes Digital zoom 1 4 continuous Detector data F...

Page 201: ...ry Yes Measurement Object temperature range 20 to 120 C 4 to 248 F 0 650 C 32 1200 F 300 C to 1200 C 572 2192 F Accuracy 2 C 3 6 F or 2 of reading for ambient tem perature 15 35 C 59 95 F and object tempera ture above 0 C 32 F Measurement analysis Spotmeter 3 in live mode Area 3 in live mode Automatic hot cold detection Auto maximum minimum markers within area Measurement presets No measurements C...

Page 202: ...ble memory SD card 8 GB Time lapse periodic image storage No Remote control operation Using FLIR Tools using USB cable FLIR Tools Mobile over Wi Fi Image file format Standard JPEG measurement data included In frared only mode Image annotations Voice 60 seconds built in microphone and speaker and via Bluetooth on still images and video Text Text from predefined list or soft keyboard on touchscreen ...

Page 203: ...n Laser Class 2 0 05 40 m 1 6 131 ft 1 of measured distance Data communication interfaces Interfaces USB 2 0 Bluetooth Wi Fi DisplayPort METERLiNK Bluetooth Communication with headset and external sensors Wi Fi Peer to peer ad hoc or infrastructure network Audio Microphone and speaker for voice annotation of images USB USB Type C data transfer video power USB standard USB 2 0 High Speed Video out ...

Page 204: ...1 489 1 radio ETSI EN 301 489 17 EN 61000 6 2 immunity EN 61000 6 3 emission FCC 47 CFR Part 15 Class B emission Radio spectrum ETSI EN 300 328 FCC Part 15 249 RSS 247 Issue 2 Encapsulation IP 54 IEC 60529 Shock 25g IEC 60068 2 27 Vibration 2g IEC 60068 2 6 Drop Designed for 2 m 6 6 ft Safety EN UL CSA PSE 60950 1 Physical data Weight including battery 1 kg 2 2 lb Size L W H 278 4 116 1 113 1 mm 1...

Page 205: ... lens 14 Extra lens 42 Hard transport case Infrared camera with lens Lens cap front Lens cap front and rear only for extra lenses Packaging weight Packaging size 500 190 370 mm 19 7 7 5 14 6 in EAN 13 4743254002791 UPC 12 845188014049 Country of origin Estonia Supplies and accessories T197771ACC Bluetooth Headset T199425ACC Battery charger T199588 Lens 14 case T199590 Lens 42 case T199589 Lens 24 ...

Page 206: ...hnical data 27 T198696 FLIR ResearchIR Max 4 hardware sec dev T199013 FLIR ResearchIR Max 4 printed license key T199043 FLIR ResearchIR Max 4 Upgrade printed license key T810190 r AJ 46209 46209 en US 194 ...

Page 207: ...24 1 0 m 3 28 ft 14 Focal length 10 mm 0 39 in 42 17 mm 0 67 in 24 29 mm 1 41 in 14 Spatial resolution IFOV 1 66 mrad pixel 42 0 90 mrad pixel 24 0 52 mrad pixel 14 Additional lenses 14 42 Lens identification Automatic f number 1 1 42 1 3 24 1 5 14 Image frequency 30 Hz Focus Continuous LDM One shot LDM One shot contrast Manual Field of view match Yes Digital zoom 1 4 continuous Detector data Foca...

Page 208: ...lery Yes Measurement Object temperature range 20 to 120 C 4 to 248 F 0 650 C 32 1200 F 300 1500 C 572 2732 F Accuracy 2 C 3 6 F or 2 of reading for ambient tem perature 15 35 C 59 95 F and object tempera ture above 0 C 32 F Measurement analysis Spotmeter 3 in live mode Area 3 in live mode Automatic hot cold detection Auto maximum minimum markers within area Measurement presets No measurements Cent...

Page 209: ...card 8 GB Time lapse periodic image storage 10 seconds to 24 hours infrared Remote control operation Using FLIR Tools using USB cable FLIR Tools Mobile over Wi Fi Image file format Standard JPEG measurement data included In frared only mode Image annotations Voice 60 seconds built in microphone and speaker and via Bluetooth on still images and video Text Text from predefined list or soft keyboard ...

Page 210: ...n Laser Class 2 0 05 40 m 1 6 131 ft 1 of measured distance Data communication interfaces Interfaces USB 2 0 Bluetooth Wi Fi DisplayPort METERLiNK Bluetooth Communication with headset and external sensors Wi Fi Peer to peer ad hoc or infrastructure network Audio Microphone and speaker for voice annotation of images USB USB Type C data transfer video power USB standard USB 2 0 High Speed Video out ...

Page 211: ...1 489 1 radio ETSI EN 301 489 17 EN 61000 6 2 immunity EN 61000 6 3 emission FCC 47 CFR Part 15 Class B emission Radio spectrum ETSI EN 300 328 FCC Part 15 249 RSS 247 Issue 2 Encapsulation IP 54 IEC 60529 Shock 25g IEC 60068 2 27 Vibration 2g IEC 60068 2 6 Drop Designed for 2 m 6 6 ft Safety EN UL CSA PSE 60950 1 Physical data Weight including battery 1 kg 2 2 lb Size L W H 278 4 116 1 113 1 mm 1...

Page 212: ...th lens Lens cap front Lens cap front and rear only for extra lenses Packaging weight Packaging size 500 190 370 mm 19 7 7 5 14 6 in EAN 13 4743254002692 UPC 12 845188013929 Country of origin Estonia Supplies accessories T197771ACC Bluetooth Headset T199425ACC Battery charger T199588 Lens 14 case T199590 Lens 42 case T199589 Lens 24 case T911705ACC USB Type C to USB Type C cable USB 2 0 standard 1...

Page 213: ...Technical data 27 T199043 FLIR ResearchIR Max 4 Upgrade printed license key T810190 r AJ 46209 46209 en US 201 ...

Page 214: ...24 1 0 m 3 28 ft 14 Focal length 10 mm 0 39 in 42 17 mm 0 67 in 24 29 mm 1 41 in 14 Spatial resolution IFOV 1 66 mrad pixel 42 0 90 mrad pixel 24 0 52 mrad pixel 14 Additional lenses 14 42 Lens identification Automatic f number 1 1 42 1 3 24 1 5 14 Image frequency 30 Hz Focus Continuous LDM One shot LDM One shot contrast Manual Field of view match Yes Digital zoom 1 4 continuous Detector data Foca...

Page 215: ...lery Yes Measurement Object temperature range 20 to 120 C 4 to 248 F 0 650 C 32 1200 F 300 1500 C 572 2732 F Accuracy 2 C 3 6 F or 2 of reading for ambient tem perature 15 35 C 59 95 F and object tempera ture above 0 C 32 F Measurement analysis Spotmeter 3 in live mode Area 3 in live mode Automatic hot cold detection Auto maximum minimum markers within area Measurement presets No measurements Cent...

Page 216: ...card 8 GB Time lapse periodic image storage 10 seconds to 24 hours infrared Remote control operation Using FLIR Tools using USB cable FLIR Tools Mobile over Wi Fi Image file format Standard JPEG measurement data included In frared only mode Image annotations Voice 60 seconds built in microphone and speaker and via Bluetooth on still images and video Text Text from predefined list or soft keyboard ...

Page 217: ...n Laser Class 2 0 05 40 m 1 6 131 ft 1 of measured distance Data communication interfaces Interfaces USB 2 0 Bluetooth Wi Fi DisplayPort METERLiNK Bluetooth Communication with headset and external sensors Wi Fi Peer to peer ad hoc or infrastructure network Audio Microphone and speaker for voice annotation of images USB USB Type C data transfer video power USB standard USB 2 0 High Speed Video out ...

Page 218: ...1 489 1 radio ETSI EN 301 489 17 EN 61000 6 2 immunity EN 61000 6 3 emission FCC 47 CFR Part 15 Class B emission Radio spectrum ETSI EN 300 328 FCC Part 15 249 RSS 247 Issue 2 Encapsulation IP 54 IEC 60529 Shock 25g IEC 60068 2 27 Vibration 2g IEC 60068 2 6 Drop Designed for 2 m 6 6 ft Safety EN UL CSA PSE 60950 1 Physical data Weight including battery 1 kg 2 2 lb Size L W H 278 4 116 1 113 1 mm 1...

Page 219: ...th lens Lens cap front Lens cap front and rear only for extra lenses Packaging weight Packaging size 500 190 370 mm 19 7 7 5 14 6 in EAN 13 4743254002708 UPC 12 845188013936 Country of origin Estonia Supplies accessories T197771ACC Bluetooth Headset T199425ACC Battery charger T199588 Lens 14 case T199590 Lens 42 case T199589 Lens 24 case T911705ACC USB Type C to USB Type C cable USB 2 0 standard 1...

Page 220: ...Technical data 27 T199043 FLIR ResearchIR Max 4 Upgrade printed license key T810190 r AJ 46209 46209 en US 208 ...

Page 221: ...t 24 1 0 m 3 28 ft 14 Focal length 10 mm 0 39 in 42 17 mm 0 67 in 24 29 mm 1 41 in 14 Spatial resolution IFOV 1 66 mrad pixel 42 0 90 mrad pixel 24 0 52 mrad pixel 14 Additional lenses 14 42 Lens identification Automatic f number 1 1 42 1 3 24 1 5 14 Image frequency 30 Hz Focus Continuous LDM One shot LDM One shot contrast Manual Field of view match Yes Digital zoom 1 4 continuous Detector data Fo...

Page 222: ...lery Yes Measurement Object temperature range 20 to 120 C 4 to 248 F 0 650 C 32 1200 F 300 1500 C 572 2732 F Accuracy 2 C 3 6 F or 2 of reading for ambient tem perature 15 35 C 59 95 F and object tempera ture above 0 C 32 F Measurement analysis Spotmeter 3 in live mode Area 3 in live mode Automatic hot cold detection Auto maximum minimum markers within area Measurement presets No measurements Cent...

Page 223: ...card 8 GB Time lapse periodic image storage 10 seconds to 24 hours infrared Remote control operation Using FLIR Tools using USB cable FLIR Tools Mobile over Wi Fi Image file format Standard JPEG measurement data included In frared only mode Image annotations Voice 60 seconds built in microphone and speaker and via Bluetooth on still images and video Text Text from predefined list or soft keyboard ...

Page 224: ...n Laser Class 2 0 05 40 m 1 6 131 ft 1 of measured distance Data communication interfaces Interfaces USB 2 0 Bluetooth Wi Fi DisplayPort METERLiNK Bluetooth Communication with headset and external sensors Wi Fi Peer to peer ad hoc or infrastructure network Audio Microphone and speaker for voice annotation of images USB USB Type C data transfer video power USB standard USB 2 0 High Speed Video out ...

Page 225: ...1 489 1 radio ETSI EN 301 489 17 EN 61000 6 2 immunity EN 61000 6 3 emission FCC 47 CFR Part 15 Class B emission Radio spectrum ETSI EN 300 328 FCC Part 15 249 RSS 247 Issue 2 Encapsulation IP 54 IEC 60529 Shock 25g IEC 60068 2 27 Vibration 2g IEC 60068 2 6 Drop Designed for 2 m 6 6 ft Safety EN UL CSA PSE 60950 1 Physical data Weight including battery 1 kg 2 2 lb Size L W H 278 4 116 1 113 1 mm 1...

Page 226: ...nch Front protection Hand strap Lanyard strap battery charger Lanyard strap camera Lens cleaning cloth Wrist strap Battery 2 ea Battery charger Extra lens 14 Hard transport case Infrared camera with lens Lens cap front Lens cap front and rear only for extra lenses Packaging weight Packaging size 500 190 370 mm 19 7 7 5 14 6 in EAN 13 4743254003347 UPC 12 845188014759 Country of origin Estonia Supp...

Page 227: ...t 24 1 0 m 3 28 ft 14 Focal length 10 mm 0 39 in 42 17 mm 0 67 in 24 29 mm 1 41 in 14 Spatial resolution IFOV 1 66 mrad pixel 42 0 90 mrad pixel 24 0 52 mrad pixel 14 Additional lenses 14 42 Lens identification Automatic f number 1 1 42 1 3 24 1 5 14 Image frequency 30 Hz Focus Continuous LDM One shot LDM One shot contrast Manual Field of view match Yes Digital zoom 1 4 continuous Detector data Fo...

Page 228: ...lery Yes Measurement Object temperature range 20 to 120 C 4 to 248 F 0 650 C 32 1200 F 300 1500 C 572 2732 F Accuracy 2 C 3 6 F or 2 of reading for ambient tem perature 15 35 C 59 95 F and object tempera ture above 0 C 32 F Measurement analysis Spotmeter 3 in live mode Area 3 in live mode Automatic hot cold detection Auto maximum minimum markers within area Measurement presets No measurements Cent...

Page 229: ...card 8 GB Time lapse periodic image storage 10 seconds to 24 hours infrared Remote control operation Using FLIR Tools using USB cable FLIR Tools Mobile over Wi Fi Image file format Standard JPEG measurement data included In frared only mode Image annotations Voice 60 seconds built in microphone and speaker and via Bluetooth on still images and video Text Text from predefined list or soft keyboard ...

Page 230: ...n Laser Class 2 0 05 40 m 1 6 131 ft 1 of measured distance Data communication interfaces Interfaces USB 2 0 Bluetooth Wi Fi DisplayPort METERLiNK Bluetooth Communication with headset and external sensors Wi Fi Peer to peer ad hoc or infrastructure network Audio Microphone and speaker for voice annotation of images USB USB Type C data transfer video power USB standard USB 2 0 High Speed Video out ...

Page 231: ...1 489 1 radio ETSI EN 301 489 17 EN 61000 6 2 immunity EN 61000 6 3 emission FCC 47 CFR Part 15 Class B emission Radio spectrum ETSI EN 300 328 FCC Part 15 249 RSS 247 Issue 2 Encapsulation IP 54 IEC 60529 Shock 25g IEC 60068 2 27 Vibration 2g IEC 60068 2 6 Drop Designed for 2 m 6 6 ft Safety EN UL CSA PSE 60950 1 Physical data Weight including battery 1 kg 2 2 lb Size L W H 278 4 116 1 113 1 mm 1...

Page 232: ...nsport case Infrared camera with lens Lens cap front Lens cap front and rear only for extra lenses Packaging weight Packaging size 500 190 370 mm 19 7 7 5 14 6 in EAN 13 4743254002814 UPC 12 845188014063 Country of origin Estonia Supplies and accessories T197771ACC Bluetooth Headset T199425ACC Battery charger T199588 Lens 14 case T199590 Lens 42 case T199589 Lens 24 case T911705ACC USB Type C to U...

Page 233: ...Technical data 27 T199013 FLIR ResearchIR Max 4 printed license key T199043 FLIR ResearchIR Max 4 Upgrade printed license key T810190 r AJ 46209 46209 en US 221 ...

Page 234: ...t 24 1 0 m 3 28 ft 14 Focal length 10 mm 0 39 in 42 17 mm 0 67 in 24 29 mm 1 41 in 14 Spatial resolution IFOV 1 66 mrad pixel 42 0 90 mrad pixel 24 0 52 mrad pixel 14 Additional lenses 14 42 Lens identification Automatic f number 1 1 42 1 3 24 1 5 14 Image frequency 30 Hz Focus Continuous LDM One shot LDM One shot contrast Manual Field of view match Yes Digital zoom 1 4 continuous Detector data Fo...

Page 235: ...lery Yes Measurement Object temperature range 20 to 120 C 4 to 248 F 0 650 C 32 1200 F 300 1500 C 572 2732 F Accuracy 2 C 3 6 F or 2 of reading for ambient tem perature 15 35 C 59 95 F and object tempera ture above 0 C 32 F Measurement analysis Spotmeter 3 in live mode Area 3 in live mode Automatic hot cold detection Auto maximum minimum markers within area Measurement presets No measurements Cent...

Page 236: ...card 8 GB Time lapse periodic image storage 10 seconds to 24 hours infrared Remote control operation Using FLIR Tools using USB cable FLIR Tools Mobile over Wi Fi Image file format Standard JPEG measurement data included In frared only mode Image annotations Voice 60 seconds built in microphone and speaker and via Bluetooth on still images and video Text Text from predefined list or soft keyboard ...

Page 237: ...n Laser Class 2 0 05 40 m 1 6 131 ft 1 of measured distance Data communication interfaces Interfaces USB 2 0 Bluetooth Wi Fi DisplayPort METERLiNK Bluetooth Communication with headset and external sensors Wi Fi Peer to peer ad hoc or infrastructure network Audio Microphone and speaker for voice annotation of images USB USB Type C data transfer video power USB standard USB 2 0 High Speed Video out ...

Page 238: ...1 489 1 radio ETSI EN 301 489 17 EN 61000 6 2 immunity EN 61000 6 3 emission FCC 47 CFR Part 15 Class B emission Radio spectrum ETSI EN 300 328 FCC Part 15 249 RSS 247 Issue 2 Encapsulation IP 54 IEC 60529 Shock 25g IEC 60068 2 27 Vibration 2g IEC 60068 2 6 Drop Designed for 2 m 6 6 ft Safety EN UL CSA PSE 60950 1 Physical data Weight including battery 1 kg 2 2 lb Size L W H 278 4 116 1 113 1 mm 1...

Page 239: ...ransport case Infrared camera with lens Lens cap front Lens cap front and rear only for extra lenses Packaging weight Packaging size 500 190 370 mm 19 7 7 5 14 6 in EAN 13 4743254002821 UPC 12 845188014070 Country of origin Estonia Supplies accessories T197771ACC Bluetooth Headset T199425ACC Battery charger T199588 Lens 14 case T199590 Lens 42 case T199589 Lens 24 case T911705ACC USB Type C to USB...

Page 240: ...Technical data 27 T199013 FLIR ResearchIR Max 4 printed license key T199043 FLIR ResearchIR Max 4 Upgrade printed license key T810190 r AJ 46209 46209 en US 228 ...

Page 241: ...ft 24 1 0 m 3 28 ft 14 Focal length 10 mm 0 39 in 42 17 mm 0 67 in 24 29 mm 1 41 in 14 Spatial resolution IFOV 1 66 mrad pixel 42 0 90 mrad pixel 24 0 52 mrad pixel 14 Additional lenses 14 42 Lens identification Automatic f number 1 1 42 1 3 24 1 5 14 Image frequency 30 Hz Focus Continuous LDM One shot LDM One shot contrast Manual Field of view match Yes Digital zoom 1 4 continuous Detector data F...

Page 242: ...lery Yes Measurement Object temperature range 20 to 120 C 4 to 248 F 0 650 C 32 1200 F 300 1500 C 572 2732 F Accuracy 2 C 3 6 F or 2 of reading for ambient tem perature 15 35 C 59 95 F and object tempera ture above 0 C 32 F Measurement analysis Spotmeter 3 in live mode Area 3 in live mode Automatic hot cold detection Auto maximum minimum markers within area Measurement presets No measurements Cent...

Page 243: ...card 8 GB Time lapse periodic image storage 10 seconds to 24 hours infrared Remote control operation Using FLIR Tools using USB cable FLIR Tools Mobile over Wi Fi Image file format Standard JPEG measurement data included In frared only mode Image annotations Voice 60 seconds built in microphone and speaker and via Bluetooth on still images and video Text Text from predefined list or soft keyboard ...

Page 244: ...n Laser Class 2 0 05 40 m 1 6 131 ft 1 of measured distance Data communication interfaces Interfaces USB 2 0 Bluetooth Wi Fi DisplayPort METERLiNK Bluetooth Communication with headset and external sensors Wi Fi Peer to peer ad hoc or infrastructure network Audio Microphone and speaker for voice annotation of images USB USB Type C data transfer video power USB standard USB 2 0 High Speed Video out ...

Page 245: ...1 489 1 radio ETSI EN 301 489 17 EN 61000 6 2 immunity EN 61000 6 3 emission FCC 47 CFR Part 15 Class B emission Radio spectrum ETSI EN 300 328 FCC Part 15 249 RSS 247 Issue 2 Encapsulation IP 54 IEC 60529 Shock 25g IEC 60068 2 27 Vibration 2g IEC 60068 2 6 Drop Designed for 2 m 6 6 ft Safety EN UL CSA PSE 60950 1 Physical data Weight including battery 1 kg 2 2 lb Size L W H 278 4 116 1 113 1 mm 1...

Page 246: ... lens 14 Extra lens 42 Hard transport case Infrared camera with lens Lens cap front Lens cap front and rear only for extra lenses Packaging weight Packaging size 500 190 370 mm 19 7 7 5 14 6 in EAN 13 4743254002838 UPC 12 845188014087 Country of origin Estonia Supplies and accessories T197771ACC Bluetooth Headset T199425ACC Battery charger T199588 Lens 14 case T199590 Lens 42 case T199589 Lens 24 ...

Page 247: ...hnical data 27 T198696 FLIR ResearchIR Max 4 hardware sec dev T199013 FLIR ResearchIR Max 4 printed license key T199043 FLIR ResearchIR Max 4 Upgrade printed license key T810190 r AJ 46209 46209 en US 235 ...

Page 248: ...Mechanical drawings 28 See next page T810190 r AJ 46209 46209 en US 236 ...

Page 249: ... G E A 6 Rev B 1 2 Scale 2016 FLIR Systems Inc All rights reserved worldwide No part of this drawing may be reproduced stored in a retrieval system or transmitted in any form or by any means electronic mechanical photocopying recording or otherwise without written permission from FLIR Systems Inc Specifications subject to change without further notice Dimensional data is based on nominal values Pr...

Page 250: ...CE Declaration of conformity 29 See next page T810190 r AJ 46209 46209 en US 238 ...

Page 251: ......

Page 252: ...r water damage 30 1 2 Figure The image below shows extensive water damage on an external wall where the water has penetrated the outer facing because of an incorrectly installed window ledge 30 2 Faulty contact in socket 30 2 1 General Depending on the type of connection a socket has an improperly connected wire can re sult in local temperature increase This temperature increase is caused by the r...

Page 253: ...rared image as local temperature increase A socket s construction may differ dramatically from one manufacturer to another For this reason different faults in a socket can lead to the same typical appearance in an infrared image Local temperature increase can also result from improper contact between a wire and socket or from difference in load 30 3 2 Figure The image below shows a series of fuses...

Page 254: ...e area where air is penetrating the frame of the building When you are inspecting a building the temperature difference between the inside and outside should be at least 10 C 18 F Studs water pipes concrete columns and similar components may resemble an insulation deficiency in an infrared image Minor differences may also occur naturally 30 4 2 Figure In the image below insulation in the roof fram...

Page 255: ...ld be sub atmospheric pressure in the house Close all doors windows and ventilation ducts and allow the kitchen fan to run for a while before you take the infrared images An infrared image of draft often shows a typical stream pattern You can see this stream pattern clearly in the picture below Also keep in mind that drafts can be concealed by heat from floor heating circuits 30 5 2 Figure The ima...

Page 256: ...Application examples 30 T810190 r AJ 46209 46209 en US 244 ...

Page 257: ...cs and the French company Cedip Since 2007 FLIR Systems has acquired several companies with world leading expertise in sensor technologies Extech Instruments 2007 Ifara Tecnologías 2008 Salvador Imaging 2009 OmniTech Partners 2009 Directed Perception 2009 Raymarine 2010 ICx Technologies 2010 TackTick Marine Digital Instruments 2011 Aerius Photonics 2011 Lorex Technology 2012 Traficon 2012 MARSS 20...

Page 258: ...13 lb can be seen Figure 31 3 2015 FLIR One an accessory to iPhone and Android mobile phones Weight 90 g 3 2 oz FLIR Systems manufactures all vital mechanical and electronic components of the camera systems itself From detector design and manufacturing to lenses and system electronics to final testing and calibration all production steps are carried out and supervised by our own engineers The in d...

Page 259: ...rning experience The staff of the ITC are also there to provide you with any application support you may need in putting infrared theory into practice 31 3 Supporting our customers FLIR Systems operates a worldwide service network to keep your camera running at all times If you discover a problem with your camera local service centers have all the equip ment and expertise to solve it within the sh...

Page 260: ...y conservation9 The sum of the total energy contents in a closed system is constant Exitant radiation radiation that leaves the surface of an object regardless of its original sources Heat thermal energy that is transferred between two objects sys tems due to their difference in temperature Heat transfer rate10 The heat transfer rate under steady state conditions is directly proportional to the th...

Page 261: ...arent temperature of the environment that is reflected by the target into the IR camera14 Spatial resolution ability of an IR camera to resolve small objects or details Temperature measure of the average kinetic energy of the molecules and atoms that make up the substance Thermal energy total kinetic energy of the molecules that make up the object15 Thermal gradient gradual change in temperature o...

Page 262: ...object and the camera The relative humidity Temperature of the atmosphere 33 2 Emissivity The most important object parameter to set correctly is the emissivity which in short is a measure of how much radiation is emitted from the object compared to that from a perfect blackbody of the same temperature Normally object materials and surface treatments exhibit emissivity ranging from approxi mately ...

Page 263: ...Look for possible reflection sources considering that the incident angle reflection an gle a b Figure 33 1 1 Reflection source 2 If the reflection source is a spot source modify the source by obstructing it using a piece if cardboard Figure 33 2 1 Reflection source T810190 r AJ 46209 46209 en US 251 ...

Page 264: ... thermocouple to measure reflected apparent temperature because a thermocouple measures temperature but apparent temperatrure is radiation intensity 33 2 1 1 2 Method 2 Reflector method Follow this procedure 1 Crumble up a large piece of aluminum foil 2 Uncrumble the aluminum foil and attach it to a piece of cardboard of the same size 3 Put the piece of cardboard in front of the object you want to...

Page 265: ...ty on the sample 4 Heat the sample at least 20 K above room temperature Heating must be reasonably even 5 Focus and auto adjust the camera and freeze the image 6 Adjust Level and Span for best image brightness and contrast 7 Set emissivity to that of the tape usually 0 97 8 Measure the temperature of the tape using one of the following measurement functions Isotherm helps you to determine both the...

Page 266: ...d to compensate for the following two facts That radiation from the target is absorbed by the atmosphere between the object and the camera That radiation from the atmosphere itself is detected by the camera 33 5 Relative humidity The camera can also compensate for the fact that the transmittance is also dependent on the relative humidity of the atmosphere To do this set the relative humidity to th...

Page 267: ...on calibration diagram18 calibration curve19 or calibration table Often the first step alone in the above definition is perceived and referred to as being cal ibration However this is not always sufficient Considering the calibration procedure of a thermal camera the first step establishes the relation between emitted radiation the quantity value and the electrical output signal the indication Thi...

Page 268: ...When performing a user calibration the result is often but not always not drift compensated This means that the values do not take into account a possible change in the camera s output when the camera s internal temperature varies This yields a larger uncertainty Drift compensation uses data obtained in climate controlled chambers All FLIR Systems cameras are drift compensated when they are first ...

Page 269: ...ternal flag is placed in the optical path and all the detector elements are exposed to the same amount of radiation originating from the shutter Therefore in an ideal situation they should all give the same output sig nal However each individual element has its own response so the output is not uniform This deviation from the ideal result is calculated and used to mathematically perform an image c...

Page 270: ...p a systematic experiment with the objective of finding a single material that would give the desired reduction in brightness as well as the maximum reduction in heat He began the experiment by actually repeating Newton s prism experiment but looking for the heating effect rather than the visual distri bution of intensity in the spectrum He first blackened the bulb of a sensitive mercury in glass ...

Page 271: ...to be true only until 1830 when the Italian investigator Melloni made his great discovery that naturally occurring rock salt NaCl which was available in large enough natural crystals to be made into lenses and prisms is remark ably transparent to the infrared The result was that rock salt became the principal infrared optical material and remained so for the next hundred years until the art of syn...

Page 272: ...uidance An infrared search system tested during this period was able to detect an approaching airplane at a distance of 1 5 km 0 94 miles or a person more than 300 me ters 984 ft away The most sensitive systems up to this time were all based upon variations of the bolometer idea but the period between the two wars saw the development of two revolutionary new infrared detectors the image converter ...

Page 273: ... Figure 36 1 The electromagnetic spectrum 1 X ray 2 UV 3 Visible 4 IR 5 Microwaves 6 Radiowaves Thermography makes use of the infrared spectral band At the short wavelength end the boundary lies at the limit of visual perception in the deep red At the long wavelength end it merges with the microwave radio wavelengths in the millimeter range The infrared band is often further subdivided into four s...

Page 274: ...fraction can possibly escape The blackness which is obtained at the aperture is nearly equal to a blackbody and almost perfect for all wavelengths By providing such an isothermal cavity with a suitable heater it becomes what is termed a cavity radiator An isothermal cavity heated to a uniform temperature generates blackbody radiation the characteristics of which are determined solely by the temper...

Page 275: ...4 10 23 Joule K T Absolute temperature K of a blackbody λ Wavelength μm Note The factor 10 6 is used since spectral emittance in the curves is expressed in Watt m2 μm Planck s formula when plotted graphically for various temperatures produces a family of curves Following any particular Planck curve the spectral emittance is zero at λ 0 then increases rapidly to a maximum at a wavelength λmax and a...

Page 276: ...orange or yellow as the temperature of a thermal radiator increases The wavelength of the color is the same as the wavelength calculated for λmax A good approximation of the value of λmax for a given blackbody tem perature is obtained by applying the rule of thumb 3 000 T μm Thus a very hot star such as Sirius 11 000 K emitting bluish white light radiates with the peak of spectral radiant emittanc...

Page 277: ... μm 36 3 3 Stefan Boltzmann s law By integrating Planck s formula from λ 0 to λ we obtain the total radiant emittance Wb of a blackbody This is the Stefan Boltzmann formula after Josef Stefan 1835 1893 and Ludwig Boltz mann 1844 1906 which states that the total emissive power of a blackbody is propor tional to the fourth power of its absolute temperature Graphically Wb represents the area below th...

Page 278: ...he ratio of the spectral radiant power absorbed by an ob ject to that incident upon it The spectral reflectance ρλ the ratio of the spectral radiant power reflected by an ob ject to that incident upon it The spectral transmittance τλ the ratio of the spectral radiant power transmitted through an object to that incident upon it The sum of these three factors must always add up to the whole at any w...

Page 279: ... of a graybody is the same as a blackbody at the same temperature reduced in proportion to the value of ε from the graybody Figure 36 8 Spectral radiant emittance of three types of radiators 1 Spectral radiant emittance 2 Wave length 3 Blackbody 4 Selective radiator 5 Graybody Figure 36 9 Spectral emissivity of three types of radiators 1 Spectral emissivity 2 Wavelength 3 Black body 4 Graybody 5 S...

Page 280: ...ation is again partially absorbed but some of it arrives at the other sur face through which most of it escapes part of it is reflected back again Although the pro gressive reflections become weaker and weaker they must all be added up when the total emittance of the plate is sought When the resulting geometrical series is summed the ef fective emissivity of a semi transparent plate is obtained as...

Page 281: ... least to a trained operator It is then his responsibility to modify the measurement situation to avoid the disturbance e g by changing the viewing direction shielding off intense radia tion sources etc Accepting the description above we can use the figure below to derive a formula for the calculation of the object temperature from the calibrated camera output Figure 37 1 A schematic representatio...

Page 282: ...ion power can now be written Equation 2 We multiply each term by the constant C of Equation 1 and replace the CW products by the corresponding U according to the same equation and get Equation 3 Solve Equation 3 for Uobj Equation 4 This is the general measurement formula used in all the FLIR Systems thermographic equipment The voltages of the formula are Table 37 1 Voltages Uobj Calculated camera ...

Page 283: ...allowed to use the cal ibration curve above the highest calibration point what we call extrapolation Imagine that we in a certain case measure Utot 4 5 volts The highest calibration point for the camera was in the order of 4 1 volts a value unknown to the operator Thus even if the object hap pened to be a blackbody i e Uobj Utot we are actually performing extrapolation of the calibration curve whe...

Page 284: ...ected radiation Atm atmosphere radia tion Fixed parameters τ 0 88 Trefl 20 C 68 F Tatm 20 C 68 F Figure 37 3 Relative magnitudes of radiation sources under varying measurement conditions LW camera 1 Object temperature 2 Emittance Obj Object radiation Refl Reflected radiation Atm atmosphere radia tion Fixed parameters τ 0 88 Trefl 20 C 68 F Tatm 20 C 68 F T810190 r AJ 46209 46209 en US 272 ...

Page 285: ...ic Engineering and Remote Sensing 8 Kern Evaluation of infrared emission of clouds and ground as measured by weather satellites Defence Documentation Center AD 617 417 9 Öhman Claes Emittansmätningar med AGEMA E Box Teknisk rapport AGEMA 1999 Emittance measurements using AGEMA E Box Technical report AGEMA 1999 10 Matteï S Tang Kwor E Emissivity measurements for Nextel Velvet coating 811 21 between...

Page 286: ...m foil 27 3 µm 0 09 3 Aluminum oxidized strongly 50 500 T 0 2 0 3 1 Aluminum polished 50 100 T 0 04 0 06 1 Aluminum polished plate 100 T 0 05 4 Aluminum polished sheet 100 T 0 05 2 Aluminum rough surface 20 50 T 0 06 0 07 1 Aluminum roughened 27 10 µm 0 18 3 Aluminum roughened 27 3 µm 0 28 3 Aluminum sheet 4 samples differently scratched 70 SW 0 05 0 08 9 Aluminum sheet 4 samples differently scrat...

Page 287: ...ass sheet worked with emery 20 T 0 2 1 Brick alumina 17 SW 0 68 5 Brick common 17 SW 0 86 0 81 5 Brick Dinas silica glazed rough 1100 T 0 85 1 Brick Dinas silica refractory 1000 T 0 66 1 Brick Dinas silica un glazed rough 1000 T 0 80 1 Brick firebrick 17 SW 0 68 5 Brick fireclay 1000 T 0 75 1 Brick fireclay 1200 T 0 59 1 Brick fireclay 20 T 0 85 1 Brick masonry 35 SW 0 94 7 Brick masonry plastered...

Page 288: ... Chromium polished 50 T 0 10 1 Chromium polished 500 1000 T 0 28 0 38 1 Clay fired 70 T 0 91 1 Cloth black 20 T 0 98 1 Concrete 20 T 0 92 2 Concrete dry 36 SW 0 95 7 Concrete rough 17 SW 0 97 5 Concrete walkway 5 LLW 0 974 8 Copper commercial burnished 20 T 0 07 1 Copper electrolytic care fully polished 80 T 0 018 1 Copper electrolytic polished 34 T 0 006 4 Copper molten 1100 1300 T 0 13 0 15 1 Co...

Page 289: ...600 T 0 02 0 03 1 Gold polished highly 100 T 0 02 2 Granite polished 20 LLW 0 849 8 Granite rough 21 LLW 0 879 8 Granite rough 4 different samples 70 SW 0 95 0 97 9 Granite rough 4 different samples 70 LW 0 77 0 87 9 Gypsum 20 T 0 8 0 9 1 Ice See Water Iron and steel cold rolled 70 SW 0 20 9 Iron and steel cold rolled 70 LW 0 09 9 Iron and steel covered with red rust 20 T 0 61 0 85 1 Iron and stee...

Page 290: ...n and steel rusted red sheet 22 T 0 69 4 Iron and steel rusted heavily 17 SW 0 96 5 Iron and steel rusty red 20 T 0 69 1 Iron and steel shiny oxide layer sheet 20 T 0 82 1 Iron and steel shiny etched 150 T 0 16 1 Iron and steel wrought carefully polished 40 250 T 0 28 1 Iron galvanized heavily oxidized 70 SW 0 64 9 Iron galvanized heavily oxidized 70 LW 0 85 9 Iron galvanized sheet 92 T 0 07 4 Iro...

Page 291: ... Lacquer black matte 100 T 0 97 2 Lacquer black shiny sprayed on iron 20 T 0 87 1 Lacquer heat resistant 100 T 0 92 1 Lacquer white 100 T 0 92 2 Lacquer white 40 100 T 0 8 0 95 1 Lead oxidized at 200 C 200 T 0 63 1 Lead oxidized gray 20 T 0 28 1 Lead oxidized gray 22 T 0 28 4 Lead shiny 250 T 0 08 1 Lead unoxidized polished 100 T 0 05 4 Lead red 100 T 0 93 4 Lead red powder 100 T 0 93 1 Leather ta...

Page 292: ...045 4 Nickel electroplated on iron unpolished 20 T 0 11 0 40 1 Nickel electroplated on iron unpolished 22 T 0 11 4 Nickel electroplated polished 20 T 0 05 2 Nickel oxidized 1227 T 0 85 4 Nickel oxidized 200 T 0 37 2 Nickel oxidized 227 T 0 37 4 Nickel oxidized at 600 C 200 600 T 0 37 0 48 1 Nickel polished 122 T 0 045 4 Nickel wire 200 1000 T 0 1 0 2 1 Nickel oxide 1000 1250 T 0 75 0 86 1 Nickel o...

Page 293: ...4 different colors 70 SW 0 68 0 74 9 Paper 4 different colors 70 LW 0 92 0 94 9 Paper black T 0 90 1 Paper black dull T 0 94 1 Paper black dull 70 SW 0 86 9 Paper black dull 70 LW 0 89 9 Paper blue dark T 0 84 1 Paper coated with black lacquer T 0 93 1 Paper green T 0 85 1 Paper red T 0 76 1 Paper white 20 T 0 7 0 9 1 Paper white bond 20 T 0 93 2 Paper white 3 different glosses 70 SW 0 76 0 78 9 P...

Page 294: ...1400 T 0 18 1 Platinum wire 500 1000 T 0 10 0 16 1 Platinum wire 50 200 T 0 06 0 07 1 Porcelain glazed 20 T 0 92 1 Porcelain white shiny T 0 70 0 75 1 Rubber hard 20 T 0 95 1 Rubber soft gray rough 20 T 0 95 1 Sand T 0 60 1 Sand 20 T 0 90 2 Sandstone polished 19 LLW 0 909 8 Sandstone rough 19 LLW 0 935 8 Silver polished 100 T 0 03 2 Silver pure polished 200 600 T 0 02 0 03 1 Skin human 32 T 0 98 2...

Page 295: ...0 06 1 Tin tin plated sheet iron 100 T 0 07 2 Titanium oxidized at 540 C 1000 T 0 60 1 Titanium oxidized at 540 C 200 T 0 40 1 Titanium oxidized at 540 C 500 T 0 50 1 Titanium polished 1000 T 0 36 1 Titanium polished 200 T 0 15 1 Titanium polished 500 T 0 20 1 Tungsten 1500 2200 T 0 24 0 31 1 Tungsten 200 T 0 05 1 Tungsten 600 1000 T 0 1 0 16 1 Tungsten filament 3300 T 0 39 1 Varnish flat 20 SW 0 ...

Page 296: ... 1 Wood pine 4 different samples 70 SW 0 67 0 75 9 Wood pine 4 different samples 70 LW 0 81 0 89 9 Wood planed 20 T 0 8 0 9 1 Wood planed oak 20 T 0 90 2 Wood planed oak 70 SW 0 77 9 Wood planed oak 70 LW 0 88 9 Wood plywood smooth dry 36 SW 0 82 7 Wood plywood untreated 20 SW 0 83 6 Wood white damp 20 T 0 7 0 8 1 Zinc oxidized at 400 C 400 T 0 11 1 Zinc oxidized surface 1000 1200 T 0 50 0 60 1 Zi...

Page 297: ... T810190 r AJ 46209 46209 en US 285 ...

Page 298: ...91 2017 09 14 T506144 xml en US 45710 2017 10 11 T506145 xml en US 45337 2017 09 25 T506146 xml en US 45097 2017 09 19 T506147 xml en US 45101 2017 09 19 T506148 xml en US 41444 2017 03 21 T506149 xml en US 42495 2017 05 06 T506150 xml en US 45104 2017 09 19 T506151 xml en US 45104 2017 09 19 T506152 xml en US 45104 2017 09 19 T506153 xml en US 45104 2017 09 19 T506154 xml en US 45609 2017 10 04 T...

Page 299: ......

Page 300: ...Systems Inc All rights reserved worldwide Disclaimer Specifications subject to change without further notice Models and accessories subject to regional market considerations License procedures may apply Products described herein may be subject to US Export Regulations Please refer to exportquestions flir com with any questions ...

Reviews: