7
Technical specifications
Function
Range
Resolution
Accuracy of
reading
Duty cycle
99.99%
0.01%
±(0.5% + 2
digits)
1. Specified from 5% to 100% of full scale reading
2. 20–80% duty cycle
7.3
Thermal measurement range specifications
Function
Thermocouple range
Accuracy (of reading)
Type K inputs (exclud-
ing probe)
–45 to 750°C (–50 to
1382°F)
±(1.0% + 2.5°C (+ 4.5°
F))
7.4
Input specifications
Function
Maximum input
AC current, DC current
10 DC/AC continuous (1000 V fuse)
AC mA, DC mA
500 mA DC/AC continuous (1000 V
fuse)
AC voltage, DC voltage
1000 V DC/AC
Thermocouple
1000 V DC/AC
Resistance, capacitance, frequency,
diode test
1000 V DC/AC
#T559824; r.8007/8011; en-US