5
Operation
5.11.2
LPF mode (ACV only)
In LPF mode, high-frequency noise is eliminated from the voltage measurement
by a low-pass filter (LPF). LPF mode is available when measuring AC voltage.
1.
Use the selector pad to select
and enable LPF mode.
5.11.3
Peak mode (ACV and ACA only)
In Peak mode, the meter captures and displays the positive and negative peak
values, and updates only when a higher/lower value is registered.
1.
Use the selector pad to select
and enable Peak mode.
2.
Press the
or
button to toggle between the display of Peak Max and
Peak Min.
•
In Peak Max mode, the
indicator is displayed.
•
In Peak Min mode, the
indicator is displayed.
5.11.4
Min/Max/Avg mode
In Min/Max/Avg mode, the meter captures and displays the minimum or maxi-
mum values and updates only when a higher/lower value is registered. The meter
can also calculate the average of the minimum and maximum values.
1.
Use the selector pad to select
and enable the Min/Max/Avg mode.
2.
Press the
or
button to cycle through the minimum, maximum, and
average reading displays. The corresponding icons are displayed:
,
, or
.
5.11.5
Frequency mode (ACV and ACA only)
In Frequency mode, the frequency is displayed in the main display and the period
or duty cycle is displayed in the secondary display. Frequency mode is available
when measuring AC voltage or current.
1.
Use the selector pad to select
and enable Frequency mode.
#T559824; r.8007/8011; en-US
19
Final
before
translation
Summary of Contents for DM93
Page 1: ...User s manual Flir DM93 Digital multimeter F i n a l b e f o r e t r a n s l a t i o n...
Page 2: ...F i n a l b e f o r e t r a n s l a t i o n...
Page 3: ...User s manual Flir DM93 T559824 r 8007 8011 en US F i n a l b e f o r e t r a n s l a t i o n...
Page 4: ...F i n a l b e f o r e t r a n s l a t i o n...
Page 39: ...F i n a l b e f o r e t r a n s l a t i o n...
Page 42: ......