7
Technical specifications
7.1
General specifications
Display
40 000-count with bar
Controls
•
6-position rotary function switch
•
4-way selector pad with center
OK button
•
(6) dedicated function buttons:
mode, range, cancel, hold, Blue-
tooth, backlight
Backlight
White LED
Work light
White LED array
Measurement ranges
See section 7.2
Electrical range
specifications
, page 26
Basic accuracy
0.06%
Measurement rate
20 per second, nominal
Display rate
2 times per second
Input impedance
>10 M
Ω
V DC, > 3 MΩ V AC in Nor-
mal mode
< 10 kΩ in Low Impedance mode
AC voltage bandwidth
45 Hz to 1 kHz
Power supply
6 × AAA batteries (LR03)
Battery life
100 hours, using alkaline batteries,
with no backlight, Bluetooth, or work
light use
Auto power off (APO)
After a programmable number of mi-
nutes of inactivity, with audible pre-
alert; reset when the function switch
or buttons are pressed. Disable func-
tion supported.
#T559824; r.8007/8011; en-US
25
Final
before
translation
Summary of Contents for DM93
Page 1: ...User s manual Flir DM93 Digital multimeter F i n a l b e f o r e t r a n s l a t i o n...
Page 2: ...F i n a l b e f o r e t r a n s l a t i o n...