FT-13 Technical Manual, Rev. 1.40 March 2013
Page 47 of 56
Write
command
Modbus
register
Function
code
Register
address
No. of
registers
Data
byte
count
Data bytes
Definition
Control
40 009
10
00,08
00,01
02
00,01
Zero
00,02
Tare
00,03
Clear
00,04…00,07
N/A
00,08
Start
00,09
Reset
00,10
Hold enable
00,11
Hold disable
00,12
Pause enable
00,13
Pause disable
00,14
Start of discharging
Operation
mode
40 010
10
00,09
00,01
02
00,01
Filling mode
00,00
Weighing mode
Target
40 011
10
00,0A
00,02
04
Designated
value [hex]
Target for next cycle
Tolerance
40 013
10
00,0C
00,02
04
Tolerance for next cycle
Coarse
40 015
10
00,0E
00,02
04
Coarse for next cycle
Fine
40 017
10
00,10
00,02
04
Fine for next cycle
CN
40 019
10
00,12
00,01
02
CN Number for next cycle
Quantity
40 022
10
00,15
00,01
04
Quantity for next cycle
Total
40 023
10
00,16
00,02
04
Total weight for next cycle
Outputs
40 026
10
00,19
00,02
04
XX,XX,XX,XX
[hex]
To set outputs manually:
Active output no.= Data bit no.
set to “1” (e.g. only Bit 1 + 8 =
“1”
only output 1 + 8 active)
Middle
40 028
10
00,1A
00,02
04
Designated
value [hex]
Middle for next cycle
Calibration
40 030
10
00,01
02
0
None
188
Zero calibration
220
Span calibration (first define the
calibration weight value in
40031)
40 031
10
00,02
04
Calibration weight value
Address
R/W
Register
address
No of
registers
Process parameters
Prog0
Prog1
Prog2
Prog3
Prog4
Prog5
Prog6
40 040
R/W
00,26
00,02
D_FILL
D_FILL
D_FILL
D_DISC
D_MSG
D_MSG
D_DISC
40 042
R/W
00,28
00,02
TARE__
TARE__
D_VALV
D_GATE
ZERO_R
GAT_CH
D_GATE
40 044
R/W
00,2A
00,02
TARE==
TARE==
D_LIFT
E_TYPE
F_TRGT
E_TYPE
40 046
R/W
00,2C
00,02
ZERO_R
SAFETY
TARE__
GAT_CH
GAT_CH
40 048
R/W
00,2E
00,02
GR-NET
ZERO_R
TARE==
ZERO_R
T_TRGT
40 050
R/W
00,30
00,02
GR-NET
SAFETY
ZERO_R
40 052
R/W
00,32
00,02
ZERO_R
40 054
R/W
00,34
00,02
GR-NET
40 056
40 058
40 060
40 062
40 064
40 066
40 068
40 070
40 072
40 074
40 076
40 078