CCaalliibbrraattiioonn ooff tthhee FFlleexxxxoottuurrii
For the calibration of the water timer see: Gardena Manual C 1060 plus Art. 1864. For calibrating the Flexxoturi, follow the
instructions below:
Photo/Picture
Description
Select the correct dosing nipple and insert it completely into the serrated
opening as shown on the left.
To choose the correct dosing nipple, see the table below with different
dosages.
Connect the extraction hoses by sliding them completely over the
serrated nipple, as shown on the left.
Cut the tubes to the desired length. Slide the ceramic weight over the
hose as far as possible. Connect the yellow foot valve/filter to the hose as
shown on the left.
Nipple calibration:
1. Fill the measuring glass with the concentrated product.
2. Using the table below, select the point closest to the desired dilution
ratio and insert it.
3. Insert the suction tube into the measuring glass.
4.Place the drain hose in an open container and press the button or handle
to activate the system. Aspirate the product until the suction hose is
completely filled.
5. Turn off the system and insert the supply hose into a 5-litre container.
6. Mark the level of the product on the measuring container.
7. Switch the system on again until the 5-litre container is completely filled.
8. Turn the system off again and read the amount of the product on the
measuring container.
9. The difference between the product levels of point 6 and 8 indicates
the quantity of the product mixed per liter.
Use a ty-wrap to secure the hose to the serrated part.