The hub will remain in synchronisation standby mode for 4 minutes. If that time is exceeded, the magnet
will need to be passed over the product again.
If you launch a test from the mobile application and you have configured the multi listening mode,
the test will be executed only on the first configured mode. (see chapter 4.2.2: “WM-Bus radio”).
4.2
Configuration File
The configuration files exchanged with the hub are in BSON format, which is a binary version of JSON.
The format described in the document is in JSON format. To convert JSON format to BSON format or vice
versa, a library available on the official website is needed: http://bsonspec.org/implementations.html.
To avoid file alteration during exchanges, a CRC32 is included in each file. See section 5.1.1.4: “File
Format”.
The WebdynEasy W M-Bus hub configuration file is in BSON format and its format is as follows:
“<uid>-config.bson”
Presentation:
The hub has a default configuration. It is therefore not necessary to put all the parameters in the
configuration file. A configuration file can be complete or partial. A configuration file containing only one
variable can therefore be sent.
JSON file parameters are case sensitive. Please respect upper and lower case characters.
It is possible to reuse the configuration file deposited by the concentrator. To do this, it is important
to rename the “<uid> -config.bson” file to “<uid> -cfg.bson”.
4.2.1 System
The product operating mode, the hub name and the log level can be modified.
PARAMETERS
DESCRIPTION
mode
Hub operating mode:
factorySettings: FACTORY SETTINGS mode
storage: STORAGE mode
run: RUN mode
name
Hub name