7 Connection
78
UMFLUXUS_F7V4-6-2EN, 2017-10-01
Tab. 7.19: Circuits of the outputs
output transmitter
external
circuit
remark
internal circuit
connection
active current
loop Px+
Px-
R
ext
< 500
Ω
passive current loop
Px+
Px-
U
ext
=
4...24 V
U
ext
> 0.021 A
.
R
ext
[
Ω
] + 4 V
example:
U
ext
= 12 V
R
ext
= 0...380
Ω
switchable current
loop
1
All switchable cur-
rent outputs are
switched to active or
passive mode at the
same time.
Px+
Px-
active current
loop:
R
ext
< 350
Ω
Px+
Px-
passive current loop:
U
ext
=
8...30 V
U
ext
> 0.021 A
.
R
ext
[
Ω
] + 8 V
example:
U
ext
= 12 V
R
ext
= 0...190
Ω
HART (active)
Px+
Px-
U
i
= 24 V
HART (passive)
Px+
Px-
U
ext
= 10...24 V
voltage output
Px+
Px-
R
i
= 500
Ω
R
ext
> 2 M
Ω
If R
ext
is lower, the accuracy is lo-
wer than specified.
frequency output
Px+
Px-
U
ext
= 5...24 V
R
c
[k
Ω
] = U
ext
/I
c
[mA]
I
c
= 1...4 mA
P1...P4: R
i
= 66.5
Ω
The number, type and connections of the outputs are customized.
R
ext
is the sum of all ohmic resistances in the circuit (e.g. resistance of the conductors, resistance of the ampere-
meter/voltmeter).
+
-
mA
+
-
mA
U
ext
-
+
+
-
mA
+
-
mA
U
ext
-
+
ƒ
G
U
i
+
-
ƒ
G
mA
ƒ
G
ƒ
G
U
ext
mA
+
-
R
i
+
-
V
+
-
R
i
R
c
U
ext
V
+
-
Summary of Contents for FLUXUS F704**-A2 Series
Page 4: ...FLUXUS F70x UMFLUXUS_F7V4 6 2EN 2017 10 01...
Page 8: ...FLUXUS F70x Table of Contents 8 UMFLUXUS_F7V4 6 2EN 2017 10 01...
Page 191: ......
Page 192: ......