2. MAINTENANCE
2.2.14. ACCESS TO
WATER HEATER
fig. 1
For most of the inspection and maintenance operations it is
necessary to remove one or more casing panels.
The side panels can only be removed after removing the front
panel.
To intervene on the front side of the water heater, proceed as
follows:
›Remove the fixing screws (1 - fig.1) placed in the
bottom edge of the front panel;
1
›Grasp the front panel in the part
and, pulling it towards you, extract it with an upward movement
(see fig. 1).
1
To intervene on the side panels of the water heater proceed as
follows:
›Remove the fixing screws (2 - fig.1) placed in the
front edge of the side panel;
›Remove the fixing screws (3 - fig.1) placed in the
bottom edge of the side panel;
2
›Grasp the base of the panel and, after having it
moved laterally, remove it by lifting it (see fig. 1).
3
3
2