1. INSTALLATION
FOR THE SPLIT SYSTEM
To adjust the diaphragms on the split system, proceed as
follows (see fig. 2):
TO
›Move the reference pointer (A-fig. 2)
scrolling on the graduated index (B-fig.2) according to the
adjustment to be made;
B.
›Fully tighten the fixing screws of the
diaphragms.
B.
TO
fig. 2
ADJUSTMENT OF THE DIAPHRAGMS FOR THE SPLIT SYSTEM Ø80 / 80
Max discharge length - Ø80 / 80
up to 0.5 + 0.5 m - Ø80 / 80
m
26
pos. df
FIXED DIAPHRAGM Ø 40 mm in the flue gas e
Diaphragm Adjustable to 2 in the air intake
from 0.5 + 0.5 to 4 + 4 m - Ø80 / 80
pos. df
FIXED DIAPHRAGM Ø 40 mm in the flue gas e
Adjustable diaphragm to 3 in the air intake
from 4 + 4 to 7 + 7 m - Ø80 / 80
pos. df
FIXED DIAPHRAGM Ø 42 mm in the flue gas e
Adjustable diaphragm to 2.2 in the air intake
from 7 + 7 to 10 + 10 m - Ø80 / 80
pos. df
FIXED DIAPHRAGM Ø 42 mm in the flue gas e
Adjustable diaphragm to 3 in the air intake
from 10 + 10 to 12 + 12 m - Ø80 / 80
pos. df
FIXED DIAPHRAGM Ø 44 mm in the flue gas e
Adjustable diaphragm to 2.2 in the air intake
from 12 + 12 to 13 + 13 m - Ø80 / 80
pos. df
FIXED DIAPHRAGM Ø 44 mm in the flue gas e
Adjustable diaphragm to 3 in the air intake
23
SF 14 EVOLUTION NOx - RAD - ENG - Manual - 2009.1_HDIMS13_firm.05_R9
1 Assembly and adjustment of the diaphragms_DOUBLE SYSTEM_SF14NOx
3