2. MAINTENANCE
2.2.18. ACTIVE FUNCTIONS SIGNALING CODES
CODE
FUNCTION
DESCRIPTION
XX (NUMBER
BETWEEN 00 AND 100)
CHIMNEY SWEEP
IT IS ACTIVATED BY HOLDING THE KEYS AT THE SAME TIME '
', THE DISPLAY WILL SHOW THE VALUE OF THE MAXIMUM PERCENTAGE SET FOR THE
SANITARY
, A
VALUE THAT CAN BE MODIFIED DIRECTLY USING THE KEYS
'
'
OF POWER
THE FUNCTION IS DEACTIVATED BY HOLDING THE KEYS AT THE SAME TIME '
IS
'OR TURNING OFF
THE WATER HEATER.
THIS FUNCTION
DOOR
THE WATER HEATER
AT MAXIMUM PRESSURE
SANITARY
FOR 15 MINUTES DEACTIVATING THE
MODULATION FUNCTION. IT IS GENERALLY USED TO CARRY OUT COMBUSTION TESTS.
' is '
.
F09
SANITARY ANTI-FREEZE
IF THE OPTIONAL ELECTRIC RESISTANCE KIT (CODE: 50-00106) IS INSTALLED IN THE WATER
HEATER, THE ANTIFREEZE SYSTEM WILL ACTIVATE WHEN THE SANITARY PROBE DETECTS A
TEMPERATURE OF 4 ° C, HEATING THE EXCHANGER PIPES UP TO 8 ° C .
2.2.19. DELAY CODES
CODE
DELAY
DESCRIPTION
T3
DELAY BETWEEN EACH IGNITION TEST
IN THE EVENT OF LOSS OF FLAME DURING BURNER IGNITION, THE WAITING TIME “T3” (50 SECONDS) IS
PERFORMED BEFORE STARTING A NEW IGNITION ATTEMPT.
T4
DELAY AFTER BLOCK RESET
(REMAINING TIME
LESS THAN 30 SECONDS)
WAIT FOR THE OPERATION TO BE REGULARLY COMPLETED. IT CAN BE RESET IMMEDIATELY BUT THE ACTUAL
UNLOCK WILL TAKE PLACE ONCE 30 SECONDS AFTER THE APPEARANCE OF THE ERROR CODE.
51
SF 14 EVOLUTION NOx - RAD - ENG - Manual - 2009.1_HDIMS13_firm.05_R9
2Cod
isiegnalationfunctions_water heater_HDIMS13_firm.05