OPERATION MANUAL
FLEXESERVE HUB®
FLEXESERVE® | Operation Manual Flexeserve Hub® | V1 AUG 2020 | 40002982
Page | 11 of 22
Electrical Connection
WARNING
Connection must only be carried out by suitably trained, qualified and skilled
engineers, in accordance with all regional and local electrical codes.
Flexeserve Hub® products are designed to be installed with dedicated power cords.
POWER SUPPLY
COUNTRY/REGION
13 AMP 1 PH
UK
16 AMP 1 PH
UK
The equipment must be connected to a branch circuit protected grounded supply in accordance with
local electrical codes.
Each unit must have its own dedicated power supply.
NOTE
For electrical ratings of the unit, refer to the electrical rating plate located inside the front top
panel of the Flexeserve Hub®. An example is shown below.
It is highly recommended to provide the equipment with an accessible means of isolation external to the
equipment, i.e. a wall isolator switch.
Electrical Ratings
The appliances are electrically rated for a 230V, 50Hz electrical supply.
TOTAL POWER
MODEL
600
1400 W
1000
2700 W
WARNING
For all types of installation, ensure that the power cord is in a safe position. Under no
circumstances should any electrical cables or power points be installed directly in
contact with any part of the unit or pose a risk to safety.
If the mains power lead becomes damaged, isolate the equipment and remove from
service immediately until a replacement is fitted by a suitably trained, qualified and
skilled engineer, in accordance with all regional and local electrical codes.
Electrical rating