Flexball Italiana S.r.l.
63
11.3. Actuator parameters
Parameters are different in relation of the type of actuator and application. The detailed parameter list for each
application is described in each specific section reported in the following pages. Here below are listed the
parameters present in any type of actuator.
Code
display
Description
Values
Factory
value
Value shown on
display (factory value)
Note
A0
Push-pull cable movement
direction
1 .. 4
4
04
dI
Delay before disengaging
the gearbox
0 .. 9,9 s
0,0 s
00
dA
Delay on the throttle
0 .. 9,9 s
0,0 s
00
CC
To be used for the check-up of the internal CANBus communication
A0
is described in section 13.2
With parameters
dI
and
dA
it is possible to set a delay time measured in tens of seconds:
•
dI
is the delay that occurs when you move the lever from forward (or reverse) to neutral. The actuator
goes to neutral only after the time set into
dI
expires.
•
dA
is the delay that occurs when you move the lever from neutral to forward (or reverse). The actuator
starts to accelerate only after the time set into
dA
expires.
With parameter
CC
you can check if the communication between the command station and the actuator is
correct. The value of the parameter corresponds to a precise physical position of the lever and it is described
in the following table:
Value shown
on display
Description
N
indicates that the command station is in neutral position
F
indicates that the command station is in forward position
R
indicates that the command station is in rear position
1-2-3-4-…..-9-A
indicates that the command station is in throttle condition: “1” is the
position of minimum gas and “A” is the position of maximum gas
Looking at the display from the front side, the left digit of the display shows the position of the left command
station lever and the right digit of the display shows the position of the right command station lever.
It is shown right lever position
according to the table above
It is shown left lever position
according to the table above