A.5
Cam rings
A.5.1
Use and storage of the cam rings
Note the following concerning the use and storage of the cam rings:
● Storage possible for up to 5 years
● Protect against direct sunlight, artificial light with a high UV‐content and extreme
temperatures
● Avoid contact with aggressive media
A.5.2
BIPEX-S cam ring (20)
Table A-11
BIPEX-S cam ring
Material
Hardness
Comment
Marking
Temperature range
PU
98 Shore A
Standard for type BGG,
BCC, BHH, BKK, BCS
red
-30 °C to +90 °C
PU
92 Shore A
Standard for type BNN
yellow
-40 °C to +90 °C
PU
80 Shore A
blue
-50 °C to +80 °C
PU
64 Shore D
green
-50 °C to +120 °C
Technical data
A.5 Cam rings
BIPEX-S 3410en
64
Operating Instructions 10/2017
Summary of Contents for BCC
Page 2: ...21 09 2017 12 18 V6 00 ...
Page 10: ...Introduction 1 3 Copyright BIPEX S 3410en 10 Operating Instructions 10 2017 ...
Page 22: ...Description BIPEX S 3410en 22 Operating Instructions 10 2017 ...
Page 32: ...Commissioning BIPEX S 3410en 32 Operating Instructions 10 2017 ...
Page 44: ...Service and support 9 1 Contact BIPEX S 3410en 44 Operating Instructions 10 2017 ...
Page 46: ...Disposal BIPEX S 3410en 46 Operating Instructions 10 2017 ...