Help: 888-426-5001
F I G u R e 12 - a
F I G u R e 12 - C
F I G u R e 12 - B
F I G u R e 12 - d
7) The display should now show
nT / ---1
as
shown in Figure 12-A. This indicates the Number
of Tanks is one. Do not change this value and
press the REGEN button to advance to
the next setting
8) The display should now show
c / 32.0
. This
indicates the Unit Capacity is 32,000 grains.
i
Use the UP or doWn button to change
this value to the one listed on page 2/calcu-
and press the REGEN
button as shown in Figure 12-B
9) The display should now show
H / 20
. This indi-
cates the Hardness is 20 gpg.
i
Use the UP or
doWn button to change this value to the
total hardness level of your water listed on
and press the
REGEN button as shown in Figure 12-C
10) The display should now show
rS / SF
as shown
in Figure 12-D. This indicates that the Reserve
Selection is Safety Factor percentage. Do not
change this value and press the REGEN button
to advance to the next setting
11) The display should now show
SF / 10
. This indi-
cates the Safety Factor is 10%. This means the
system will leave 10% of the softening capacity
for the day before regeneration.
Use the UP
button to change the value to 15%
and press
the REGEN button as shown in Figure 12-E
12) The display should now show
do / 14
as
shown in Figure 12-F. This indicates the Day
Override is 14 days; the system will regenerate
in 14 days if the meter has not measured water
consumption to have reached the calculated
capacity. Do not change this value and press the
REGEN button
F I G u R e 12 - e
F I G u R e 12 - F