PAGE 12

QualityWaterForLess.com

Help: 888-426-5001

F I G u R e   12 - a

F I G u R e   12 - C

F I G u R e   12 - B

F I G u R e   12 - d

7)  The display should now show 

nT / ---1

 as 

shown in Figure 12-A. This indicates the Number 
of Tanks is one. Do not change this value and 
press the REGEN button to advance to  
the next setting

8)  The display should now show 

c / 32.0

. This 

indicates the Unit Capacity is 32,000 grains.  

i

 

Use the UP or doWn button to change 

this value to the one listed on page 2/calcu-

lated on pages 4 and 5

 and press the REGEN 

button as shown in Figure 12-B

9)  The display should now show 

H / 20

. This indi-

cates the Hardness is 20 gpg. 

i

 

Use the UP or 

doWn button to change this value to the 

total hardness level of your water listed on 

page 2/calculated on page 4 

and press the 

REGEN button as shown in Figure 12-C

10)  The display should now show 

rS / SF

 as shown 

in Figure 12-D. This indicates that the Reserve 
Selection is Safety Factor percentage. Do not 
change this value and press the REGEN button 
to advance to the next setting

11)  The display should now show 

SF / 10

. This indi-

cates the Safety Factor is 10%. This means the 
system will leave 10% of the softening capacity 
for the day before regeneration. 

Use the UP 

button to change the value to 15%

 and press 

the REGEN button as shown in Figure 12-E

12)  The display should now show 

do / 14

 

as 

shown in Figure 12-F. This indicates the Day 
Override is 14 days; the system will regenerate 
in 14 days if the meter has not measured water 
consumption to have reached the calculated 
capacity. Do not change this value and press the 
REGEN button

F I G u R e   12 - e

F I G u R e   12 - F

Summary of Contents for 5600SXT

Page 1: ...Fleck 5600 SXT Metered Water Softener Install ation Guide v1 0...

Page 2: ...values of H hARDNESS C UNIT cAPACITY and Bf bRINE FILL The remaining values that are already filled in are general standards for all softener sizes and hardness levels MASTER PROGRAMMING MODE To enter...

Page 3: ...e of a new water softener with Fleck 5600 SXT Meter Control Valve from QualityWaterForLess com We have put together these instructions as reference and to be used as general installation guidelines It...

Page 4: ...L are the same measure and both figures can be used interchangeably If you get a hardness level in PPM or mg L please divide this number by 17 1 to get Grains gpg Ex If your hardness is measured at 3...

Page 5: ...K 12 Min 18 lbs TOO SMALL Grid 3 Legs Grid 3 Legs Grid 3 Legs Grid 6 Legs Grid 6 Legs 12 25 gpg 81K 20 Min 30 lbs TOO SMALL TOO SMALL Grid 6 Legs Grid 6 Legs 25 gpg 96K 30 Min 45 lbs TOO SMALL TOO SMA...

Page 6: ...ig u r e 6 a Fig u r e 6 B pre install ation Before assembly of your new system be sure that the following conditions have been met for the place ment of your system Level firm surface such as concret...

Page 7: ...stalling the fleck 5600 sx t Valve 1 Using caution not to lift the riser tube remove the filling funnel and tape While using the included silicone lubricant packet lu bricate the inner and outer o rin...

Page 8: ...lines and use a wet rag on the lines being soldered to prevent heat damage during soldering 6 Once all connections have been made place the system into bypass by either using your existing 3 valve byp...

Page 9: ...lso take this moment to prepare and insert the brine support grid determined from pages 4 and 5 Then pull the 474 Brine Float Assembly out of the brine well as shown in Figure 9 C 4 Next fix the 474 B...

Page 10: ...be evenly press on both sides of the grey ring surrounding the tube and pull out as shown in Figure 10 A i Be sure to recut the end of the tube each time you remove it to ensure a proper seal when the...

Page 11: ...ime to scroll faster Once the time display is set to 12 01 PM press the REGEN button once as shown in Figure 11 B 3 To enter MASTER PROGRAMMING MODE press the UP and DOWN buttons TOGETHER and HOLD bot...

Page 12: ...your water listed on page 2 calculated on page 4 and press the REGEN button as shown in Figure 12 C 10 The display should now show RS SF as shown in Figure 12 D This indicates that the Reserve Selecti...

Page 13: ...Figure 13 A This indicates the system will regenerate at 2 00 AM following the day the water consumption has passed the calculated capacity If you prefer an alternate regeneration time please enter i...

Page 14: ...reen stops flashing BW let BW Backwash run for about 1 minute to observe the water leave out the drain line and check for leaks If you notice any leaks return to page 10 to review preparing the drain...

Reviews: