1   › CalCul atInG HaRdness, CaPaCIt y, and BRIne FIll

1) 

Water Test: Before start-up, it is crucial that you know your water’s HardneSS and Iron levels in 

order to set up your unit properly.

 If your unit is not programmed with your particular hardness level, it will 

either regenerate too early or too late. If you do not know your water hardness or iron levels, you can take a 
sample of your untreated water to a local pool shop, hardware store, or well driller 

(city water has no iron)

2) 

Initial Hardness:

 Your Hardness test results may be recorded in Grains per Gallon (gpg), Parts per Million 

(PPM), or Milligrams per Liter (mg/L). Note that 

PPM and mg/l are the same measure

 and both figures can 

be used interchangeably. 

If you get a hardness level in PPM or mg/l, please divide this number by 17.1 

to get Grains (gpg).

 Ex: If your hardness is measured at 300 PPM, take 300 / 17.1 = 18 gpg before iron

3) 

 H - coMPenSaTed HardneSS: 

 Your Iron results should also be measured in either PPM or mg/L. 

Take 

your level of iron multiplied by 5 and add it to the hardness level from the previous step.

 This final figure 

will be your 

compensated Hardness level

 

that we will program into your softener system. Ex: If your iron level 

is measured at 2 PPM, add 2 x 5 = 10 Grains of hardness to existing hardness total. 18 + 10 = 28 Grains Total

4) 

The compensated hardness level you just calculated will be the “H” value you use to program your 

softener. You may record this in the table on page 2.

 Depending on your compensated hardness level, 

you will be able to use a different salt setting for programming and running your softener unit. The lower the 
hardness level, the more efficient you will be able to be with salt consumption for regeneration

Summary of Contents for 5600SXT

Page 1: ...Fleck 5600 SXT Metered Water Softener Install ation Guide v1 0...

Page 2: ...values of H hARDNESS C UNIT cAPACITY and Bf bRINE FILL The remaining values that are already filled in are general standards for all softener sizes and hardness levels MASTER PROGRAMMING MODE To enter...

Page 3: ...e of a new water softener with Fleck 5600 SXT Meter Control Valve from QualityWaterForLess com We have put together these instructions as reference and to be used as general installation guidelines It...

Page 4: ...L are the same measure and both figures can be used interchangeably If you get a hardness level in PPM or mg L please divide this number by 17 1 to get Grains gpg Ex If your hardness is measured at 3...

Page 5: ...K 12 Min 18 lbs TOO SMALL Grid 3 Legs Grid 3 Legs Grid 3 Legs Grid 6 Legs Grid 6 Legs 12 25 gpg 81K 20 Min 30 lbs TOO SMALL TOO SMALL Grid 6 Legs Grid 6 Legs 25 gpg 96K 30 Min 45 lbs TOO SMALL TOO SMA...

Page 6: ...ig u r e 6 a Fig u r e 6 B pre install ation Before assembly of your new system be sure that the following conditions have been met for the place ment of your system Level firm surface such as concret...

Page 7: ...stalling the fleck 5600 sx t Valve 1 Using caution not to lift the riser tube remove the filling funnel and tape While using the included silicone lubricant packet lu bricate the inner and outer o rin...

Page 8: ...lines and use a wet rag on the lines being soldered to prevent heat damage during soldering 6 Once all connections have been made place the system into bypass by either using your existing 3 valve byp...

Page 9: ...lso take this moment to prepare and insert the brine support grid determined from pages 4 and 5 Then pull the 474 Brine Float Assembly out of the brine well as shown in Figure 9 C 4 Next fix the 474 B...

Page 10: ...be evenly press on both sides of the grey ring surrounding the tube and pull out as shown in Figure 10 A i Be sure to recut the end of the tube each time you remove it to ensure a proper seal when the...

Page 11: ...ime to scroll faster Once the time display is set to 12 01 PM press the REGEN button once as shown in Figure 11 B 3 To enter MASTER PROGRAMMING MODE press the UP and DOWN buttons TOGETHER and HOLD bot...

Page 12: ...your water listed on page 2 calculated on page 4 and press the REGEN button as shown in Figure 12 C 10 The display should now show RS SF as shown in Figure 12 D This indicates that the Reserve Selecti...

Page 13: ...Figure 13 A This indicates the system will regenerate at 2 00 AM following the day the water consumption has passed the calculated capacity If you prefer an alternate regeneration time please enter i...

Page 14: ...reen stops flashing BW let BW Backwash run for about 1 minute to observe the water leave out the drain line and check for leaks If you notice any leaks return to page 10 to review preparing the drain...

Reviews: