background image

PAGE 14

QualityWaterForLess.com

Help: 888-426-5001

F I G u R e   14 - a

19)  The system will now exit Master Programming 

mode and the display should now show the 
time of day followed by the number of gal-
lons remaining as shown in Figure 14-A. Now 
change the time of day to your current time 
with either the UP or DOWN button. 

Be care-

ful to note the presence or absence of the 

PM indicator in the top right corner.

 Confirm 

the time with the REGEN button

8   ›I n I t I a l   s ta R t- u P

1)  With one nearby softened faucet running in the COLD position, slowly open your bypass valve or 3-valve bypass 

to about ¼ open to allow the air trapped in the softener to escape via your running faucet. 

noTe: opening the 

bypass too quickly or too open may damage your softener or plumbing

2)  Allow the softener tank to slowly fill with water. After a few minutes, you will see a trickle of water coming from 

the cold water faucet. Allow the water to run slowly in this manner for an additional 5 minutes. Next, with the 
cold water faucet still running, gradually move your bypass valve to the fully open position. 

noTe: You may see 

some initial discoloration from the softened water – this is normal and should dissipate within the first 

40-50 gallons of water used.

 Turn off the running cold water faucet when the water runs clear

3) 

 

i                  

To test the integrity of your new system and all connections

,

 it is strongly encouraged that you per-

form a short form regeneration to check for leaks before service. 

Begin this process by adding approximately 

5 gallons of water/the amount of water needed to cover the brine grid into the brine tank. Start the regeneration se-
quence by HOLDING the REGEN button for 5 seconds. Once the screen stops flashing BW, let BW - Backwash run 
for about 1 minute to observe the water leave out the drain line and check for leaks. If you notice any leaks, 

return to 

page 10

 to review preparing the drain connection. Click the REGEN button ONCE to move on to BD - Brine Draw

4)  Once the screen stops flashing BD, let BD - Brine Draw run for about 1 minute to observe the water level in the 

brine tank being drawn lower. Also check the brine line and the float valve in the brine well for leaks. If the water 
level doesn't lower or there is a leak

return to pages 9 and 10

 to review preparing the brine tank connection. 

Click the REGEN button ONCE to move on to RR - Rapid Rinse

5)  Once the screen stops flashing RR, advance from RR - Rapid Rinse to BF - Brine Fill by clicking the REGEN button 

ONCE more. Once the screen stops flashing BF, let BF - Brine Fill run for about 1 minute to observe the water 
level in the brine tank rise. Also check the brine line and float valve in the brine well for leaks. If the water level 
doesn't rise or there is a leak

return to pages 9 and 10

 to review preparing the brine tank connection. Click the 

REGEN button ONCE to finish

6)  Now you may add 120-160 pounds of pellet, solar, or block salt to your brine tank. 

always keep your brine tank 

filled with salt to at least above the water level. 

You do not need to perform a regeneration immediately after 

installation as the new resin arrives at full softening capacity. Simply let your softener meter automatically trigger 
regenerations by tracking the water consumption 

› C o n G R at u l at I o n s

Your new softener with Fleck 5600 SXT Meter Valve is now properly in-
stalled and programmed! Please maintain your system by keeping the softener 
plugged-in and always keep your brine tank filled with salt to at least above 
the water level. We appreciate your business, and hope that you enjoy years of 
trouble-free softened water!

Summary of Contents for 5600SXT

Page 1: ...Fleck 5600 SXT Metered Water Softener Install ation Guide v1 0...

Page 2: ...values of H hARDNESS C UNIT cAPACITY and Bf bRINE FILL The remaining values that are already filled in are general standards for all softener sizes and hardness levels MASTER PROGRAMMING MODE To enter...

Page 3: ...e of a new water softener with Fleck 5600 SXT Meter Control Valve from QualityWaterForLess com We have put together these instructions as reference and to be used as general installation guidelines It...

Page 4: ...L are the same measure and both figures can be used interchangeably If you get a hardness level in PPM or mg L please divide this number by 17 1 to get Grains gpg Ex If your hardness is measured at 3...

Page 5: ...K 12 Min 18 lbs TOO SMALL Grid 3 Legs Grid 3 Legs Grid 3 Legs Grid 6 Legs Grid 6 Legs 12 25 gpg 81K 20 Min 30 lbs TOO SMALL TOO SMALL Grid 6 Legs Grid 6 Legs 25 gpg 96K 30 Min 45 lbs TOO SMALL TOO SMA...

Page 6: ...ig u r e 6 a Fig u r e 6 B pre install ation Before assembly of your new system be sure that the following conditions have been met for the place ment of your system Level firm surface such as concret...

Page 7: ...stalling the fleck 5600 sx t Valve 1 Using caution not to lift the riser tube remove the filling funnel and tape While using the included silicone lubricant packet lu bricate the inner and outer o rin...

Page 8: ...lines and use a wet rag on the lines being soldered to prevent heat damage during soldering 6 Once all connections have been made place the system into bypass by either using your existing 3 valve byp...

Page 9: ...lso take this moment to prepare and insert the brine support grid determined from pages 4 and 5 Then pull the 474 Brine Float Assembly out of the brine well as shown in Figure 9 C 4 Next fix the 474 B...

Page 10: ...be evenly press on both sides of the grey ring surrounding the tube and pull out as shown in Figure 10 A i Be sure to recut the end of the tube each time you remove it to ensure a proper seal when the...

Page 11: ...ime to scroll faster Once the time display is set to 12 01 PM press the REGEN button once as shown in Figure 11 B 3 To enter MASTER PROGRAMMING MODE press the UP and DOWN buttons TOGETHER and HOLD bot...

Page 12: ...your water listed on page 2 calculated on page 4 and press the REGEN button as shown in Figure 12 C 10 The display should now show RS SF as shown in Figure 12 D This indicates that the Reserve Selecti...

Page 13: ...Figure 13 A This indicates the system will regenerate at 2 00 AM following the day the water consumption has passed the calculated capacity If you prefer an alternate regeneration time please enter i...

Page 14: ...reen stops flashing BW let BW Backwash run for about 1 minute to observe the water leave out the drain line and check for leaks If you notice any leaks return to page 10 to review preparing the drain...

Reviews: