1 - GENERAL OPERATION
3200 NT
17
E
N
G
L
I
S
H
Display panel functions
Service indicator:
- Valve in service:
L.E.D lit
- Delayed regeneration:
flashing L.E.D.
Programmation indicator:
- Valve in programmation :
L.E.D. lit
Diagnostic button
Value setting buttons
Flow indicator:
The L.E.D. flashes proportionally
to the flow
L.E.D. not used in metric
mode
Regeneration button
Press this button to start a manual regeneration.
- In timeclock or meter delayed, pressing the button will start a regeneration on the set time.
Pressing the button 5 seconds will start an immediate regeneration.
- In timeclock or meter delayed, when pressing the button, the service indicator flashes, will start
a regeneration the same day on the set time.
- In meter immediate mode, pressing the button will start an immediate regeneration.
Setting buttons
These buttons are used to set the time as well as the values of parameters whilst programming
the electronics.
Diagnostic button D
This button allows to access diagnostic functions.
This information is a maintenance help: instant flow, peak flow, totaliser, number of hours
between the two last regenerations, number of hours since the last regeneration, remaining
capacity, valve position, and electronic card version.
Regeneration button
1
1.1
1.2
1.3