![Flavor Burst CTP 80BEV-INT Operation Manual Supplement Download Page 41](http://html.mh-extra.com/html/flavor-burst/ctp-80bev-int/ctp-80bev-int_operation-manual-supplement_2303418041.webp)
40
23. Channel the 9-Tube Assembly tubes
through the slot on the modified Taylor back
panel. Use the slot closest to the side of the
freezer the 9-Tube Assembly is installed
(left side of freezer is recommended).
24. Pull open the plastic grommet and place it
around the 9-Tube Assembly tubes. Snap
the grommet into the hole on the modified
Taylor panel.
25. Install the plastic plug into the other hole on
the modified Taylor panel.
26. Install the modified back panel to the Taylor
cabinet and reinstall the side panel.
Filling the Sanitizer Tank
Use only NSF approved sanitizer solution
mixed according to the manufacturer’s
instructions in the Sanitizer Tank. The tank
system delivers solution to specific areas of the
Flavor Burst
®
system such as the Spout
Assembly and syrup lines during certain
functions. In order to utilize these clean-in-
place functions, keep an adequate supply of
approved sanitizer solution in the Sanitizer
Tank at all times.
The Sanitizer Tank should be checked on a
daily basis. For proper sanitation, keep only
FRESH sanitizer solution in the tank. Some
sanitizer solutions may become ineffective after
a few days and may not clear the system of all
bacteria present. See the sanitizer
manufacturer’s information for potency and
longevity. Replace older solution with fresh
solution when necessary. Additionally, use hot
water when mixing the sanitizer solution, as it
will be much more effective in cleaning the
system.
1. Prepare approximately 2 gallons (7.5 Liters)
of approved sanitizer solution according to
manufacturer’s instructions.
2. Disconnect the sanitizer line by pressing the
lever on the Sanitizer Tank fitment and
pulling the sanitizer supply line free.
3. Remove the Sanitizer Tank from the
cabinet.
26412
26417
26414
26416
26247
26249