background image

USER GUIDE                                                       

HOW TO PROGRAM AND USE THE FLASH PROGRAMMER 2S 

 
 

WHY A PROGRAMMER 

 

 

 

 

  FOR GREATER CONTROL OF YOUR COMFORT: 

- The temperature you need at a time that suits you. 

 

  FOR GREATER CONTROL OVER YOUR ENERGY COSTS: 

- Slightly lowering the temperature during the night or when you are not at home can achieve 
  substantial savings. 

 
 

PRINCIPLE OF OPERATION 

 

FLASH PROGRAMMER 2S ALLOWS YOU TO PROGRAM TWO HEATING ZONES 

 

Example: 

- Day zone for the dining room, living room etc 
- Night zone for the bedroom etc 

 
THE TIMES YOU PROGRAM FOR EACH ZONE DEFINE THE COMFORT HEATING TIMES AND THE 
REDUCED HEATING TIMES 
 

 Comfort 

Temperature  : The temperature you want in the house when you are at home, which can be set  

                                                  Individually for each room. 

 

  Reduced Temperature    : The temperature you want in the house when you are away or at night 

 

MANUAL OPERATION FOR EACH INDIVIDUAL ZONE 1 AND 2 

                 

 

PROGRAMMING 

 
The dual zone time switch allows you to program 20 comfort or reduced switching times spread anywhere over 
the two zones. 
e.g. 12 switching times for zone 1 and 8 for zone 2. 
 
Each switching time can be applied to one or several days of the week. 
e.g. comfort mode from Monday to Friday at 7.00 represents one switching time. You now have 19 left. 
 

 
 
 

Summary of Contents for Programmer 2 S

Page 1: ...designers since January 1994 TECHNICAL CHARACTERISTICS Time switch Electronic clock with day and week programs Power backup By lithium battery backup guarantee for a total of 3 years minimum against mains failure battery life 10 years Program increments 1 minute Number of zones 2 Total maximum current rating 0 5A Dimensions 167mm x 84mm x 44mm INSTALLATION 1 Unscrew the time switch fixing screw 2 ...

Page 2: ... ELECTRICAL CONNECTIONS FOR PILOT WIRE CONVECTOR HEATERS 1 All types of convectors since 1994 The pilot wire carries the live current to the convector Inputs connect neutral to L1 and Live to L2 2 Convectors before January 1994 Check the convector instructions or if you have none consult the manufacturer In certain cases the pilot wire carries the neutral current to the convector inputs In this ev...

Page 3: ...ROGRAM FOR EACH ZONE DEFINE THE COMFORT HEATING TIMES AND THE REDUCED HEATING TIMES Comfort Temperature The temperature you want in the house when you are at home which can be set Individually for each room Reduced Temperature The temperature you want in the house when you are away or at night MANUAL OPERATION FOR EACH INDIVIDUAL ZONE 1 AND 2 PROGRAMMING The dual zone time switch allows you to pro...

Page 4: ...3 Thu 4 Fri 5 Sat 6 Sun 7 Comfort Example 07 00 Reduced Example 08 00 Comfort Reduced Comfort Reduced Comfort Reduced Comfort Reduced Comfort Reduced ZONE 2 The first lines are filled with an example ZONE 2 C2 Times Mon 1 Tue 2 Wed 3 Thu 4 Fri 5 Sat 6 Sun 7 Comfort Example 20 00 Reduced Example 23 00 Comfort Reduced Comfort Reduced Comfort Reduced Comfort Reduced Comfort Reduced ...

Page 5: ...1 SETTING THE TIME 2 PROGRAMMING 5 ...

Page 6: ...3 AUTO MODE 4 CHECKING SWITCHING TIMES 6 ...

Page 7: ...5 MODIFYING OR CANCELLING SWITCHING TIMES 7 ...

Page 8: ...MER MODE 7 TEMPORARILY OVERRIDING TIMER MODE HOLIDAYS etc APPLIED ENERGY PRODUCTS LIMITED MORLEY WAY PETERBOROUGH PE2 9JJ TEL 44 0 01733 456789 FAX 44 0 01733 310606 Website www creda heating co uk Leaflet No 22671AA Revision A 8 ...