Summary of Contents for TSTATBBPB101

Page 1: ...tions TSTATCCPB101 TSTATBBPB101 P474 1010 Digital Thermostat NOTE Re_d _ an_r_ kmauc_n n_kU Ee_oee iqllhv_ the ir_ ab_n 0 HEAT COOL HEAT PUMP MULTI STAGE SINGLE DAY PROGRAMMABLE Fonlt IM TSTAT_7 Can_ _ in U_ _ NO 13T_TA43 ...

Page 2: ...ONDITIONER BEFORE REMOVING THEOLD THERMOSTAT AND INSTALLING THENEW THERMOSTAT WARNING Replacement Components Division _ Carder Corporation 4 01 This device complies with Part 15 of the FCC rules Operation is subject to the following 2 conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired o...

Page 3: ...hese steps call a qualified technician for assistance Assemble tools as shown below Flat B ade Screwdriver Wire cutter when not using Stripper j box Make sure your Heater Air Conditioner is working properly before beginning installation of the thermostat Carefully unpack the thermostat Save the screws wall anchors and instructions Page 2 ...

Page 4: ...t does not come off easily check for screws Loosen the screws holding the thermostat base or subbase to the wall and lift away Disconnect the wires from the old thermostat Tape the ends of the wires as you disconnect them and mark them with the letter of the terminal for easy reconnection to the new thermostat Keep the old thermostat for reference purposes until your new thermostat is functioning ...

Page 5: ... wiring diagrams that follow Wire from the Install on the old thermostat terminal marked GorF Y1 YorC Wl Wor H Rh R M Vr _ C O 13 Y2 W2 RS 5 RS RS G CK1 CK2 Function Fan Cooling Heating Power Common Rev Valve 2nd Stage Cool 2nd Stage Heat Remote Sensor Svdc Remote Ser _ Sigttal _emote Sensc_Gmum Dry Conte_ swi_ 1 D_ Contact_itch 2 new thermostat connector marked G Y1 Wl O B R C Wl O B Y2 W2 C may ...

Page 6: ... vac return If using electnc heat this option must he selected on during advanced setup L E C G YI O Wl R Y2 42 4 Wire 1 Stage Cooling 1 Stage Gas Heat 0 Resideri_l Gas or _ Heat W2 2 R Wl Y1 G C ElectricCool splitsystems package _ Thermostat units fan mlav compressor relay x x x 1st staoe heat circuit 24 vac return ff using e_ctric heat this option must he selected on dutYngadvanced setup Poge5 L...

Page 7: ...compressor relay if usingelectricheat thisoptionmust beselecteddu ngadvancedsetup m L E _ C _ G _ Y1 X O Wl R Y2 W2 6 Wire 1 Stage Cooling 2 Stage Heat 0 Residen_aJ comrnenSal 1 StageCooling W2 Y2 R Wl YI G C _th 2 StageGas or ElectricHeat _ _ Thermostat fr 24 vac common fan mlav comDP_sor reJav 1st staae heat circuit 24 vac mtum _nd _tRg_ hRAt rJrPJ dt Poge6 L E C Y1 O Wl _ _ R Y2 N2 ...

Page 8: ...1st staae heat circuit _ _ Wl 24 vac return _ R 2nd staqe compressor relay K Y2 2nd _tR_n_ h_t PJrrJlff _ _ N2 _ ffus_ng e_ic heat Fnisoptionmust be selectedon duringadvancedsetup 5 Wire 1 Stage Cooling 1 Stage Heat Heat Pump O RW_ylr_ r No au dlia_heat residen_alHeat Pumps W2 Y2 _ splitsystems packageunits Thermostat J J 24 vac common fan relay ComDressor relsv reversino valve lf using_ l _J heat...

Page 9: ...ostat is calibrated before it leaves the factow Under normal circumstances there will never be a need to recalibrate the thermostat again To accommodate specialneeds the thermostat may be recalibrated following these steps 1 While holding the mode button in press the down button for 2 seconds After all the icons in the display appear release the buttons 2 Press the mode button 3 Press the up or do...

Page 10: ... button repeatedly until the COOL icon appears on the display Press the up down buttons until the set temperature is 10 degrees below room temperature The air conditioner should turn on NOTE Most equipment has a time delay of 5 minutes between cool cycles This feature is defeatable on the thermostaL Consult the Owner s Manual under Setup cycles per hour Press the MODE button to OFF Press the FAN b...

Page 11: ...low For ProblemA C ForProblemHeat SYMPTOM The air conditioning does not attempt to tum on CAUSE_ The compressor timer lockout may prevent the air conditioner fTom turning on for a period of time REMEDY Consult the Owner s Manual in the Setup section to defeat the cycles per hour and compressor timeguard SYMPTOM The display is blank CAUSE Lack of proper power REMEDY Make sure power is turned on to ...

Page 12: ...et too high REMEDY Consult the Owner s Manual in the Setup section to lower the cooling setpoint limit SYMPTOM The heating does not attempt to turn on CAUSE The heating setpoint is set too low REMEDY Consult the Owner s Manual in the Setup section to raise the heating setpoint limit Poge 11 ...

Page 13: ... the Owner s Manual SYMPTOM When calling for cooling both the heat and cool come on CAUSE The Advanced Setup is configured to control a heat pump and the hvac the thermostat is controlling is a conventional non heat pump system REMEDY Consult the Owner s Manual in the Advanced Setup section to turn off the heat pump STAR TSTATCCPB101 TSTATIBBI_101 P474 1010 v_U_F_ _rds F_X_ P_ME OR _FK_ USE 4Z95 P...