N61e V1.0 or Higher
10/23
For lithium type, FAST/STD/SLOW/STG/MANU functions are available.
The detail refers to
Table.N61e Operating Function Option
.
Par5.
SAFE TIME
This safe time protects a pack from heavy
overcharge. The preset range is INH, 1
…
990 Min. ‘INH’ means N61e will ignore this
stop condition. If the timer reaches SAFE
TIME, N61e will auto stop charging even if
the pack is not full. So please refer to the
following formula to set a suitable SAFE time.
SAFE TIME = (Charge Capacity / Operating Current * 1.5).
If a battery’s actual capacity is empty, you can refer to the quick data:
FAST: 45Min STD: 90Min
SLOW: 180Min. STG: 180Min
Par6.
CAP. MAX
You can define the max charging capacity to avoiding overcharging. This
percentage value relates to the set capacity. The range is INH, 1
…
120%
for lithium. ‘INH’ means N61e will ignore this stop condition.
Par7.
RESET BATT.
For avoiding the mis-operation when you
press the dial to reset the memory, N61e
needs you to confirm that are you SURE to
reset Batt.M? Pressing the dial briefly will
execute it. But if you change your mind,
pressing the EXIT or the dial will stop the reset function. Reset does not
means delete, merely that the Batt.M will lose the old information but the
position will still exist.
Par8.
HISTORY
In this page you can review a summary of
the N61e recent operating history.
Par9.
INPUT
It displays current Input voltage.
Par10.
BATT.
It displays batteries’ voltage if you connect
them properly with the output of N61e.
Par11.
Cells voltage
It displays the voltage per cell if you connect
the balancer adapter with your pack. It shows zero with no connection. The
Page.3(Par7)
RESET BATT.
Page.4(Par8)
HISTORY: LiPo3S
-4500mAh 0h00
Page.5(Par9/10)
INPUT: 14.000V
BATT.: 12.000V
Page.2 (Par5/6)
SAFE TIME: 80Min
CAP. MAX: 120%
Summary of Contents for N61e