Flash Technology
Revision A - 2/13/2020
46
# OR RLY BOARDS
(Number of Relay Boards)
0-4
RELAY BOARD CONFIG
RELAY BOARD[1-4] CONFIG
RLY[1-14]:
UNASSIGNED
T1 GENERAL ALARM
AOL TIER GENERAL ALARM
MKRT# GENERAL ALARM
TWILIGHT MODE
T#B# GENERAL ALARM
AOLBCN# GENERAL ALARM
CATENARY CONFIG
FH 372 BCN#
MIDDLE
TOP
BOTTOM
MONITORING CONFIG
This option selects the type of monitoring for the system. The options include Local Ethernet Configuration,
Primary Data Monitoring and Alternate Data Monitoring.
NOTE: DRY CONTACT MONITORING IS AVAILABLE REGARDLESS OF ANY ADDITIONAL METHOD
SELECTED TO MONITOR THE SYSTEM.
LOCAL ETHERNET CONFIGURATION
The options available in the Local Ethernet Configuration provide a way to configure the FTC 270 to properly
operate on the connected network.
When the FTC 270 utilizes a cellular modem the settings should be as follows:
IP Address Mode: Static
IP Address: 192.168.1.11
Subnet Mask: 255.255.255.0
Default Gateway: 192.168.1.10
The MAC Address is not editable.