6.16
MEASUREMENT POINT
REGISTRATION
Set the sensors so that they are
approximately at the same rotational angle
at the first measurement position.
Select the register icon and
press OK.
This registers the first reading.
Rotate the shafts to the next position. The
shafts must be rotated over a minimum of
45°.
Green sector show permitted positions.
Red sector show forbidden positions. The
Register icon is not shown if the rotation is
less than 45°.