  The  resistance  of  the  pulley  and  its 

anchorage must be calculated for a double effort of 
the lifted load. 

2.1.3

 

Reeving for lifting of load 

Use the reeving kit ref 438900. 
This assembly allows you to double the capacity of 
the device. In return, the speed is decreased by half. 

 The LM must not be otherwise than with this 

reeving  kit  assembled.  Additional  system  must  not 
be added. 
The reeving kit consists of an anchor carrier strand 
and a reeving block with a hook and a spring. 

The  user  should  note  that  when  reeving,  the 
required length of wire rope is at least twice the lift 
height,  plus  at  least  1  meter  of  apparent  slack 
strand. 

The  limit  spring  mounted  on  the  lower  pulley  is 
intended to replace the high limit stop. 
A  stop  may  still  be  placed  on  the  loose  strand  to 
serve as low end stopper. 

 In case of reeving, double the maximum load 

to  be  taken  into  account  for  the  calculations  of 
security. 

NOTA : take care to mount the pulley block so that 
its  limit  spring  is  located  on  the  cable  between  the 
pulley and the entry in the hoist (see figure). 

  Check  the  triggering  of  your  travel  limit 

switch  before  use;  a  repositioning  of  the  stoppers 
may be necessary depending on the configuration of 
job. 

 Check the capacity of the anchoring points. 

When operating with the reeving system, especially 
the operator will ensure that the load is not turning 
on  itself,  to  avoid  tangling  the  three  strands  of  the 
cable (two strands loaded and the slack side). 

Summary of Contents for LM250A

Page 1: ...MANUAL Electrical winches LM90A LM250A R f 1813000156 Page 1 17 Version 23 21 INSTALLATION USE MAINTENANCE Monitoring of updates Date Description 08th Jun 2021 New format type A for Radio option modif...

Page 2: ...ARNINGS ABOUT CONTRAINDICATIONS 10 2 7 RESIDUAL RISKS 11 2 8 TRANSPORTATION HANDLING STORAGE 11 3 MAINTENANCE SETTINGS 11 3 1 MAINTENANCE OPERATIONS 11 3 1 1 Preventive maintenance 11 3 1 2 Adjusting...

Page 3: ...r work such as in an elevator shaft or on building facades The winch uses one steel cable hoisting cable The drive system consists of a pulley whose throat has a special profile and in which the cable...

Page 4: ...a record of incidents and actions taken to remedy them forecast dates of periodic inspections and record of actual dates of inspections 1 6 Recommendations for use and general safety Before using thi...

Page 5: ...r the effort to apply If the anchoring is not provided by FIXATOR each anchor must withstand without any deformation up to 2 5 times the WLL of the winch that is 2 5x90 225 kg respectively 2 5x250 625...

Page 6: ...ualified technician 2 1 1 Suspended installation It s the simplest mounting and the most common Device in suspension and direct traction or lifting The anchoring of the device must be done exclusively...

Page 7: ...ft height plus at least 1 meter of apparent slack strand The limit spring mounted on the lower pulley is intended to replace the high limit stop A stop may still be placed on the loose strand to serve...

Page 8: ...e main power plug 2 1 4 2 Commissioning Unlock the emergency stop if necessary Press the UP button to lift or pull the load Press the DOWN button to lower the load At any time in case of imminent dang...

Page 9: ...t the outgoing winch cable slack is free Do not let the loaded rope become slack if the load is not stable resting on a strong enough support 2 2 Diagrams and safety explanations Installation and use...

Page 10: ...he load Avoid heavy slipping Wait for a complete stop of your installation before resuming movement Check regularly that no obstacle is located along the path of movement above and below the load 2 4...

Page 11: ...ust be reviewed at least once a year and every 100h In harsh environments sandblasting marine back and forth operation at full load doubts about the proper use etc a higher frequency of verifications...

Page 12: ...ly original FIXATOR parts ask the complete list of spare parts 3 1 3 Lubricating controling a hoist cable The hoisting cable must be regularly greased or lubricated with Teflon For this use for exampl...

Page 13: ...ensor is activated The motor is blocked The contactors in the hoist are off or disconnected Error in the control circuit Error in the power circuit Wait until it cools Check the motor Reconnect or cha...

Page 14: ...nd stopper ref 540620 Capacitor 40uF ref 540582 Pendant control ref 461020 Motor cap ref 540601 Fuse ref 244612 3 4 Disposal Disassembly and disposal of the hoist must be in accordance with the curren...

Page 15: ...INSTRUCTION MANUAL Electrical winches LM90A LM250A R f 1813000156 Page 15 17 Version 23 21...

Page 16: ...ntensity of use 4 2 1 Model ref 461025 This model follows the recommendations of EN60204 32 2008 It contains a transmitter IP65 and a receiver with internal antenna IP66 range 75 to 100m Frequency ban...

Page 17: ...6 Page 17 17 Version 23 21 The original of this document is in French no translation can replace it P A 8 rue du Bois Rinier B P 10041 49181 ST BARTHELEMY D ANJOU France TEL 33 0 2 41 31 17 00 FAX 33...

Reviews: