SAFETY CONSIDERATIONS 

Read and follow instructions carefully. Improper 
installation may damage Air Cleaner. 
 
Understand the signal words 

WARNING

  and 

CAUTION

 

which are present in the Owner’s Manual.  

WARNING

 

and 

CAUTION

  signify a hazard which could result in 

personal injury, property damage or death. 
 

WARNING 

Before beginning any installation or modification, be 
certain that the main line electrical disconnect switch 
is in the OFF position. Electric shock could result. Tag 
disconnect switch with suitable warning labels. 

 

Only a heating/air conditioning installer or qualified 
service person should install your Air Cleaner, 
unless you are completely familiar with the 
necessary tools, equipment and potential hazards 
involved. If you plan to install this Air Cleaner 
yourself,  please be aware that the improper use of 
any tool can be dangerous. The manufacturer will 
not assume any responsibility for failures due to 
incorrect installation procedures. 
 
Homeowners can perform the basic maintenance 
functions of replacing filters. 
 
When working on the Air Cleaner, observe 
precautions in the Owner’s Manual, labels attached 
to the unit, and other safety precautions that may 
apply.  Follow all safety codes.  Wear safety glasses 
and work gloves. 

 
 

WHAT THE AIR CLEANER DOES

 

Your Air Cleaner  has been designed to remove 
atmospheric and household dust, coal dust, insecticide 
dust, mites, pollen, mold spores, fungi, bacteria, pet 
dander, cooking smoke and grease, tobacco smoke and 
more down to 0.3 micron (1/84,000 of an inch). 
 
 

BENEFITS

 

 

Provides relief from allergy and asthma suffering. 

 

Prevents damaging black dust from staining walls, 
upholstery and window coverings, reducing the 
amount of time and money spent cleaning and 
redecorating. 

 

Eliminates unpleasant odors with optional carbon 
filters. 

 

Protects costly heating/cooling equipment, 
prolonging operating efficiency. 

 

 

 

HOW IT WORKS

 

Millions of airborne pollutants are carried through the 
return air ducts of the heating/cooling system to the 
Media Air Cleaner. Here the particles are captured by 
the media filter. 
 
The media filter is constructed of continuous 
hydrophobic polyolefin fibres that will not shred or 
absorb moisture.  The media's unique design features a 
structured density gradiant with an electret charge for 
higher initial and sustained efficiency.  The media is 
supported by an open steel mesh and enclosed by a 
high wet-strength beverage board.  The filter has an 
Underwriter's Laboratories Class 2 rating. 
 
The efficiency of the filter is MERV 11, based on the 
ASHRAE Standard 52.2. Test  velocity is 492 
feet/minute.  An arrow indicates direction of air flow. 
 

Composite Average 

Efficiency Value 

Composite 

Minimum Range 

(Microns) 

Average Composite 

Minimum Values 

E1 

0.3 - 1.0 

26.0% 

E2 

1.0 - 3.0 

65.5% 

E3 

3.0 - 10.0 

85.4% 

 
The clean air then passes through the carbon filters (3), 
where odors are adsorbed (optional).  The carbon filter is 
a polyester pad impregnated with activated carbon. An 
aluminum frame is used to support the filter. Activated 
carbon with its naturally unique porous structure, allows 
excellent odor removal.  

 

INSTALLATION

 

IMPORTANT:  

This media filter will cause more of a 

restriction on your air handling system than a regular 
equipment filter, because of its increased efficiency. The 
pressure drop of a clean filter at 50% of rated air flow is 
0.040  inches W.C. The same filter at 100% of rated air 
flow is 0.135  inches W.C. As the filter collects 
contaminants, the pressure drop increases. This media 
filter is not recommended where the pressure drop is 
critical. 
 

LOCATION

 

Your Air Cleaner is adaptable to all residential forced air 
furnaces or cooling systems. The Air Cleaner must be 
installed in the return air duct close to the blower 
compartment. This location provides the most even air 
flow across the filter and allows the Air Cleaner to keep 
the system motor and fan clean. 
 

HUMIDIFIERS

 

A humidifier should be installed in the furnace warm air 
duct. However, it may be installed in the return duct 
without causing problems to your Air Cleaner. Care must 
be taken that the humidifier does not leak, as this may 

Summary of Contents for FSMF3225

Page 1: ...aner is ideal for 5 ton air handling systems Handles up to 2800 cfm High Efficiency MERV 11 Media Filters 2 remove airborne pollutants as small as 0 3 micron No maintenance except for filter replacement No electrical hook up required Heavy gauge galvanized steel cabinet and powder coat paint finish resist corrosion and provide trouble free installation ...

Page 2: ...r ducts of the heating cooling system to the Media Air Cleaner Here the particles are captured by the media filter The media filter is constructed of continuous hydrophobic polyolefin fibres that will not shred or absorb moisture The media s unique design features a structured density gradiant with an electret charge for higher initial and sustained efficiency The media is supported by an open ste...

Page 3: ...ller Air Cleaner This will increase the velocity of air flow and may decrease cleaning efficiency 5 Turning vanes If the Air Cleaner is installed adjacent to an elbow or angle fitting turning vanes are recommended to improve air distribution across the filter 6 Seal the joints in the return air system All joints between the Air Cleaner and the heating cooling equipment should be sealed to prevent ...

Page 4: ...g of either defective parts or replacement parts Such costs may be covered by a separate warranty provided by the FIVE SEASONS dealer LIMITATIONS OF WARRANTY All implied warranties including implied warranties of merchantability are hereby limited in duration to the period for which the limited warranty is given The expressed warranties made in this warranty are exclusive and may not be altered en...

Reviews: