24
TROUBLE SHOOTING GUIDE
1.
No display on the console after the power is started:
The probable reason is that the wire from the console to the bottom control board
is not connected well or the transformer is burnt out. Take off the upright frame
tubes and check every single connection part of the wires from the console to the
bottom control board and make sure that all the wires are connected well. If the
problem is caused by the defective wires or the defective transformer, please do
the replacement by the new wires or transformer.
2.
E01—Communication failure:
The probable reason is that the communication from the console to the bottom
control board is
stuck.
Check every single connection part of the wires from the
console to the bottom control board and make sure that all the wires are
connected well. If the problem is caused by the defective wires, do the
replacement by the new wires.
3.
E02—Burst clash protection:
Check if the voltage is lower than 50% of the normal voltage and do the testing
again by the correct voltage. Check if the control board has strange smell, if it is,
please use a new control board to do the replacement. Check if the motor wires are
connected well, and re-connect the motor wires well.
4.
E03—No sensor signal:
The probable reason is that the speed sensor signal has not been received during
10 minutes, check if the sensor signal light of the bottom control board is flashing,
if not, please use the new part to do the replacement. Check if the sensor plug is
connected well or if the magnetic sensor is broken, re-connect the sensor plug or
change the magnetic sensor with the new one.
5.
E04—Incline leaning failure:
Check if the VR wire of the incline motor is connected well, re-connect the VR wire
plug. Check if the AC wire of the incline motor is connected well, connect the AC
wire of the incline motor with the correct position of the control board. Check if the
motor connection wires are broken, if yes, do the change by the new wires or the
new incline motor. Press the button of the bottom control board to re-work after all
the checkings are done well.
6.
E05—Current overload protection:
The probable reason is that the user’s weight is over limit loading and causes too
much current, so the unit starts self-protection system. If a certain part of the
treadmill is stuck, it may also cause the problems that the motor can not rotate,
the loading is over the limit and the current is too much. Adjust the treadmill well
Summary of Contents for MIRACLE R270
Page 22: ...21 EXPLODED DIAGRAM...
Page 49: ...48 SCHEMATICK POHLED NA ZA ZEN...
Page 55: ...54...
Page 56: ...55 1 2 3 4 5 6 7 8 9...
Page 57: ...56 10 11 12 13...
Page 59: ...58 S 13 14 15 1 1 2 3 5 3 4 M8 16 86 115...
Page 60: ...59 4 5 6 4 9 10 3 4 M6 12 5 1 M8 35 90 23 26 3 4 4 2 13 108...
Page 61: ...60 7 30 31 ST4 2 12 107...
Page 62: ...61 15 15...
Page 63: ...62 1760 775 1350 830 775 1620 460 1320 69 15 120 1 0 20 LCD...
Page 64: ...63 120...
Page 73: ...72 PAUSE...
Page 74: ...73 4 30 5 12 6 3...
Page 75: ...74...
Page 76: ...75 3 5 A A...
Page 77: ...76 3 3 5 5 3...
Page 78: ...77...
Page 81: ...80 1 2 E01 3 E02 50 4 E03 10 5 E04 VR 6 E05 7 START...
Page 82: ...81...