8.4.12 Compatible with new controller RG52I
Through RG52I controller, five function parameters of air conditioners can
be adjusted immediately. There is no need to change the chip anymore.
1, Auto restart function
Press “ADJUST” button, choose “F1”. Press “MODIFY” button, Press
“ADJUST” .Then choose “ON” or “OFF” button to active the auto restart function
or shut off the function. Press “CONFIRM” button at last.
2, Temp. compensation.
Press “ADJUST” button, choose “F2”. Press “MODIFY” button, Press “ADJUST”
to choose the temp. value(
0~6)
. Press “CONFIRM” button at last.
3, Anti-cold wind function
Press “ADJUST” button, choose “F3”. Press “MODIFY” button, Press “ADJUST”
to choose “1” or “2”. Press “CONFIRM” button at last.
“1” : intelligent defrosting mode.
“2” :common defrosting mode.
4, Indoor fan speed of when setting temp. is achieved.
Press “ADJUST” button, choose “F4”. Press “MODIFY” button, Press “ADJUST”
to choose “1” or “2” or “3”. Press “CONFIRM” button at last.
“1”: Indoor fan stops when setting temp. is achieved.
“2”: Indoor fan keeps at lowest fan speed when setting temp. is achieved.
“3”: Indoor fan keeps at setting fan speed when setting temp. is achieved.
5, Louver position memory function
Press “ADJUST” button, choose “F5”. Press “MODIFY” button, Press “ADJUST”
to choose “1” or “2” or “3”. Press “CONFIRM” button at last.
“1”: Louver position is not memorized.
“2”: Louver position is active, even when power off and AC shuts off.
“3”: Louver position is active, even when AC shuts off, while Inactive when power
off.
Summary of Contents for FSAIF-Pro-123AE2
Page 8: ...8 O optional function ...
Page 13: ...13 5 Wiring Diagram FSAIF Pro 93AE2 FSAIF Pro 183AE2 FSAIF Pro 243AE2 ...
Page 14: ...14 FSAIF Pro 123AE2 ...
Page 15: ...15 5 2 Outdoor Unit FSOAIF Pro 93AE2 ...
Page 16: ...16 FSOAIF Pro 123AE2 ...
Page 17: ...17 FSOAIF Pro 183AE2 ...
Page 18: ...18 FSOAIF Pro 243AE2 ...
Page 61: ...61 9 2 7 IPM malfunction or IGBT over strong current protection diagnosis and solution P0 ...
Page 62: ...62 9 2 8 Over voltage or too low voltage protection diagnosis and solution P1 ...
Page 63: ...63 9 2 9 High temperature protection of compressor top diagnosis and solution P2 ...
Page 64: ...64 9 2 10 Inverter compressor drive error diagnosis and solution P4 ...