Gas Conversion
Conversion to LP/Propane Gas
• This range can be used with NATURAL or LP/PROPANE gas. It is shipped from the factory adjusted for use with
NATURAL gas.
• Any conversion required must be performed by your dealer, a qualified licensed technician or gas service
company. Provide the service person with this manual before any work is started on the range. (Gas
conversions are the responsibility of the dealer or end user.)
• The range is supplied with a set of injectors required for converting the range burners.
• Refer to the following table to select the appropriate size injector. The nozzle diameters (hundredths of a
millimetre) are marked on the body of each injector.
• This range can be used with NATURAL or LP/PROPANE gas. It is shipped from the factory
adjusted for use with NATURAL gas.
• Any conversion required must be performed by your dealer, a qualified licensed technician or
gas service company. Provide the service person with this manual before any work is started on
the range. (Gas conversions are the responsibility of the dealer or end user.)
• The range is supplied with a set of injectors required for converting the range burners.
• Refer to the following table to select the appropriate size injector. The nozzle diameters
(hundredths of a millimetre) are marked on the body of each injector.
Setting the Pressure Regulator
The pressure regulator is accessible by removing the storage/warmer drawer; the pressure regulator is positioned on the
rear right side of the range
C.