517762
5
1 SERVICING
REQUIREMENTS
1.1
Health & Safety
Note: When servicing the Intuitive
TM
electronic dryer, health and safety issues must be
considered at all times. Specific safety issues are listed below to remind service people of
the health and safety issues.
1.2 Electrical
Safety
WARNING! TO AVOID ELECTRIC SHOCK!
Do not attempt to service this dryer without suitable training and qualifications.
Ensure the mains power has been disconnected before servicing any part of the dryer. If the
power is required to be on for electrical fault finding, or checking the operation, then
extreme
care
should be taken not to make contact with electrical components other than with testing probes.
Ensure the dryer is turned off when removing any electrical component or connection.
1.3 Electrostatic
Discharge
Electronic components are prone to damage from electrostatic discharges. The electronic
modules in this product contain no user serviceable components and breaking seals to access
internal components of an electronic module may void the product warranty. Avoid contact with
PCB edge connectors when handling electronic modules.
1.4
Good Working Practices
Ensure the work areas are kept tidy and free of hazards while servicing the dryer. On completion
of the servicing, ensure the dryer and work areas are left clean and tidy.
1.5 Safety
Test
On completion of any service carried out to the dryer, all safety tests as required by law must be
carried out.
1.6
Sheet Metal Edges
When working around cut sheet metal edges use appropriate gloves or protection to eliminate the
chance of receiving a laceration.
Summary of Contents for Intuitive DE62T27GW
Page 2: ...517762 2 ...
Page 22: ...517762 22 13 WIRING DIAGRAM ELECTRIC ...
Page 23: ...517762 23 14 WIRING DIAGRAM GAS ...
Page 24: ...517762 24 ...
Page 25: ...517762 25 NOTES ...