Depending on the nature of the User Warning, the operation of the dryer may cease or continue to
‘limp on’ until the cycle finishes or the user intervenes.
Pressing the
Power
button when a User Warning is displayed will immediately turn the dryer off.
User Warnings are saved to memory as Fault Codes, and the last Fault Code will be permanently
stored.
The warning will also be recorded in the Warning Status screen (refer to Section 7.1.1) however
the information on this screen will only be stored for as long as power is supplied to the dryer.
When the dryer is isolated from the supply the information in this screen will be erased.
6.2
Fault Code Summary
The following are the fault codes that may be displayed. The remedy section of each fault is the
suggested sequence of repair or replacement. If the first suggestion does not remedy the fault,
check the next on the list.
Fault Code 1
Communications Error.
Communications failure between the sensor module and motor control module.
Remedy: (1) Check the continuity of the module interconnecting harness.
(2) Replace the sensor module.
(3) Replace the motor control module.
Fault Code 2
Drum Gap Cannot be Located.
Remedy: (1) Ensure the sensor module is correctly located and clipped into place.
(2) Replace the lens on the sensor module.
(3) Replace the sensor module.
(4) Remove the top deck and clean the drum sensing “bumps” on the outside of
the drum end.
(5) Replace the drum.
Fault Code 3
Drum Stalled.
Remedy: (1) If there is mechanical movement of the drum, but this fault code is appearing,
follow the procedures for fault code 2.
(2) If there is no mechanical movement of the drum, check drum movement
mechanisms: belt, motor and motor harness.
(3) Replace the motor control module.
(4) Replace the motor.
Fault Code 4
Invalid Option Link Read.
The motor control module heat source option link read is invalid.
Remedy: Replace the motor control module.
Fault Code 6
Door Jammed – (User Warning).
The door is unable to close due to either clothes catching or an excessive closing load.
Remedy: (1) Remove the obstruction.
(2) Reposition or remove some of the load.
(3) Fix the cause of binding in the door closing mechanism.
(4) Replace the motor.
Fault Code 7
Motor Current Excessive.
Remedy: (1) Free up the dryer. Remove overload or cause of jamming.
(2) Replace the motor control module.
(3) Replace the motor.
Fault Code 7b Display Module RAM Check Error
On power up, the display has checked its memory against a known reference and found
differences.
Remedy: Replace the display module.