517762
13
Fault Code 45 Display Module ROM Check Error
On power up, the display has checked its memory against a known reference and found
differences.
Remedy: Replace display module.
Fault Code 105 Comms Error Time Out
Communications failure between the sensor module and display module.
Remedy: (1) Visually check the contacts on the RAST (edge) connector at each end on
the harness between the sensor module and display module.
(2) Using a multimeter check for continuity of the wires on this harness.
(3) Replace display module.
(4) Replace sensor module.
Note:
On the LCD model, the green Air Dry LED illuminated without the fault “beeps”
indicates the dryer is in a low mains voltage (brown out) state, and may be
momentarily displayed when the supply power is turned off.
On the LED model, the Wrinkle Free LED illuminated without the fault “beeps”
indicates the dryer is in a low mains voltage (brown out) state, and may be
momentarily displayed when the supply power is turned off.