5
BUILT-IN CONSTRUCTION
CAVITY DIMENSIONS
PBE1 MODELS
INCHES
MM
A
Height of cutout
10 1/8
257
B
Depth of cutout
22 3/4
578
C
Width of cutout
22 1/2
572
D
Depth of gas supply opening
4
102
E
Width of gas supply opening
4 15/16
125
F
Height of countertop recess
6-12
152 - 305
G
Minimum distance from countertop recess to cutout
3
76
a
I
b
c
d
f
g
e
As the power burner is designed for larger cookware, it is recommended that the product is mounted 6-12” below the countertop. Sufficient space should also be left around the product for safe
cookware handling.
Notes:
• When determining a suitable location, take into account concerns such as exposure to wind, proximity to traffic paths,
and keeping any gas supply lines as short as possible.
• Locate the unit in a well-ventilated area.
• The counter and supporting ledges or deck must be level and flat.
• The enclosure should have ventilation holes to prevent gas build-up in the event of a leak. Refer to ANSI Z21.58
Standard for Outdoor Cooking Gas Appliances, Section 1.7 Enclosures For Self Contained LP-Gas Supply Systems.
Notes:
• To purchase access doors and drawers, visit dcsappliances.com
• 24” access doors model number:
ADN1-20x24
• 24” access drawers model number:
ADR2-20x24
CUTOUT DIMENSIONS
PBE1 MODELS
INCHES
MM
A
Height of cutout
11 1/8
283
B
Depth of cutout
23 3/4
603
C
Width of cutout
28 7/8
734
D
Depth of gas supply opening
4
102
E
Width of gas supply opening
4
102
F
Depth to gas supply opening from front of cutout
18 1/2
470
G
Width to gas supply opening from side of cutout
3 1/2
89
H
Height of countertop recess
6-12
152 - 305
I
Minimum distance from countertop recess to cutout
18
457
RECESSED CUTOUT
RECESSED INSULATED JACKET CUTOUT
If the unit is to be placed into a combustible enclosure, an insulated jacket is required.
a
F
G
b
c
e
d
ventilation
ventilation
H