BURNER ADJUSTMENT

FLAME HEIGHT ADJUSTMENT

LOW FLAME ADJUSTMENT

The valve for the outer burner feature an adjustable low setting. Due to fluctuations in gas 
pressure, or heating value you may feel it necessary to increase or decrease gas flow in the 
low position. 

1

3

4

2

Remove the dial.

While holding the valve shaft with pliers, 
insert a flat-tipped screwdriver into the 
shaft and, while viewing the burner, adjust 
to a minimum stable flame.

Push in and hold the selected dial 
for 2 seconds before turning to 

HI

Hold for 10 seconds to light the 
selected burner.

Turn the control dial counter-
clockwise to the lowest setting.

BEZEL FRONT VIEW

Flames should be blue and stable with no yellow tips, excessive noise or lifting (Note: LP 
units may have some yellow tipping). If any of these conditions exist, check the air shutter 
and burner ports are clear. If cleaning these does not improve performance, the air shutter 
for the outer burner can be adjusted as below.

yellow tips

noisy/lifting

blue + stable

1

3

4

2

With a screw driver, loosen the lock screw 
on the face of the air shutter. If the flame 
is yellow turn the air shutter counter-
clockwise, if the flame is noisy and tends 
to lift turn the air shutter clockwise.

Light to check adjustment. If the flame 
is blue and stable, tighten the air shutter 
screw and replace all parts. If flame is still 
unstable, repeat the above steps.

Ensure the power burner is 

OFF

 and cool.

To access the air shutter, remove the 
trivets and burner hob. The hob can 
be removed by unscrewing the four 
screws from each corner. 

The burner should not be removed.

BURNER TOP VIEW

Summary of Contents for DCS PBE1

Page 1: ...PBE1 Models POWER BURNER INSTALLATION GUIDE US CA ...

Page 2: ...ounded power outlet Never remove the grounding plug or use with a 2 prong adapter Use only extension cords with a 3 prong grounding plug rated for the power of the equipment and approved for outdoor use with a W A marking Do not immerse cord or plugs in water or other liquid WARNING Fire Hazard Failure to follow this advice may result in a fire causing death or serious injury This unit is for outd...

Page 3: ...de Keep any electrical supply cord and the fuel supply hose away from any heated surfaces WARNING To reduce the risk of fire injury to persons or damage when using the appliance follow the important safety instructions listed below Read all the guidance before using the appliance Do not use an outdoor cooking gas appliance for purposes other than intended Servicing z Do not repair or replace any p...

Page 4: ...o the orifice correctly and ensure they are level before lighting to prevent fire hazard or explosion Refer to the user guide for detailed guidance z Use only a Ground Fault Interrupter GFI protected circuit with this outdoor cooking gas appliance z Unplug from the outlet when not in use and before cleaning Allow to cool before putting on or taking off parts z Do not operate the appliance with a d...

Page 5: ... Overall depth excluding dials 26 7 8 683 D Depth of chassis 22 1 2 572 E Width of chassis including support brackets 21 3 4 552 F Height below countertop 10 1 8 257 G Height of surface above countertop 9 16 14 H Depth of control panel to front of chassis 2 51 I Depth from control panel to rear of product 25 9 16 649 J Depth of lid 23 585 K Width of lid 23 5 8 600 L Height of lid 1 11 16 43 ...

Page 6: ...es or deck must be level and flat The enclosure should have ventilation holes to prevent gas build up in the event of a leak Refer to ANSI Z21 58 Standard for Outdoor Cooking Gas Appliances Section 1 7 Enclosures For Self Contained LP Gas Supply Systems Notes To purchase access doors and drawers visit dcsappliances com 24 access doors model number ADN1 20x24 24 access drawers model number ADR2 20x...

Page 7: ... be level and flat The enclosure should have ventilation holes to prevent gas build up in the event of a leak Refer to ANSI Z21 58 Standard for Outdoor Cooking Gas Appliances Section 1 7 Enclosures For Self Contained LP Gas Supply Systems Notes To purchase access doors and drawers visit dcsappliances com 24 access doors model number ADN1 20x24 24 access drawers model number ADR2 20x24 CUTOUT DIMEN...

Page 8: ...ons the power burner drops into the opening and hangs from its side flanges A deck is not required to support it from the bottom Do not use this appliance under unprotected overhead combustible surfaces Fisher Paykel recommends installing the manual shut off valve in a location readily accessible by the customer so that gas to the appliance can be shut off in an emergency situation However the app...

Page 9: ...must not be modified in any way to accommodate such placement A spirit level should be used to ensure that the unit is level both front to back and side to side If it is not level burner combustion may be erratic or the unit may not function efficiently for grease flow a a Insulated jacket If the power burner is to be placed into a combustible enclosure an approved insulated jacket is necessary In...

Page 10: ...lock to form the cooking surface To install the trivets position the feet onto the products ledge and slot the trivets together A small pot support is supplied with the Power Burner for cooking with pots smaller than 8 To install the pot support slot onto the centre of the main trivet assembly as shown above ...

Page 11: ... power transformer to operate the products ignition and dial illumination features The transformer is sealed in a box with an attached power supply cord ELECTRICAL CONNECTION TO OUTLET Dial halos When a dial is in use an orange halo around that dial will illuminate This will change from orange to white if the dial is turned to OFF but another dial remains active If all dials are turned OFF all hal...

Page 12: ...nnect an unregulated gas line to the appliance You must use a gas regulator even if the supply is controlled The appliance and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 1 2 PSIG 3 5 kPa The appliance must be isolated from the gas supply piping system by closing its individual manual...

Page 13: ...hould be equipped with the proper equipment to fill your tank Do not attempt to remove repair or replace the regulator hose assembly This must be done by qualified and licensed technician only 1 2 Prepare soap solution by combining one part liquid detergent and one part water Pour into a spray bottle Ensure all control valves are in the OFF position before turning the gas supply ON Check all conne...

Page 14: ...s excessive noise or lifting Note LP units may have some yellow tipping If any of these conditions exist check the air shutter and burner ports are clear If cleaning these does not improve performance the air shutter for the outer burner can be adjusted as below yellow tips noisy lifting blue stable 1 3 4 2 With a screw driver loosen the lock screw on the face of the air shutter If the flame is ye...

Page 15: ... or with adjacent burner lit the pressure regulator is connected and set for 4 W C Natural 11 0 W C LP gas the manual shut off valve is installed and accessible the unit has been tested and is free of leaks the user is informed of gas supply shut off valve location Complete and keep for safe reference Model Serial No Purchase Date Purchaser Dealer Address Installer s Name Installer s Signature Ins...

Page 16: ...tions in this document apply to the specific products and models described at the date of issue Under our policy of continuous product improvement these specifications may change at any time You should therefore check with your Dealer to ensure this document correctly describes the product currently available ...

Reviews: