8
BUILT-IN CLEARANCES
CLEARANCE DIMENSIONS
PBE1-30 MODELS
INCHES
MM
A
Minimum distance from combustible surface to power burner (above the
cook surface)
18
457
Clearances to combustible construction
Any materials of a building structure or decorative structure made
of wood, compressed paper, plant fibres, vinyl/plastic or other
materials that are capable of transferring heat or being ignited
and burned. Such material shall be considered combustible even
though flame-proofed, fire-retardant treated or surface-painted,
or plastered.
Do not use this appliance under unprotected overhead
combustible surfaces.
Fisher & Paykel recommends installing the manual shut-off
valve in a location readily accessible by the customer, so that
gas to the appliance can be shut off in an emergency situation.
However, the appliance must not be modified in any way to
accommodate such placement.
A spirit level should be used to ensure that the unit is level
both front-to-back and side-to-side. If it is not level, burner
combustion may be erratic or the unit may not function
efficiently for grease flow.
a
a
Insulated jacket
If the power burner is to be placed into a combustible enclosure,
an approved insulated jacket is necessary. Insulated jackets are
available from your dealer. Use only the DCS insulated jacket
which has specifically been designed and tested for this purpose.
Review the detail drawing shown and take into account the
provisions shown for gas line connection clearance in the right
rear corner. It is required that ventilation holes are provided in the
enclosure to eliminate the potential build-up of gas in the event
of a gas leak. The supporting ledges or deck must be level and
flat and strong enough to support the power burner and insulated
jacket. The counter should also be level.
24” insulated jacket part number:
71426