47
ALARM ON
* Defrost heater
-
Check display for any fault code
-
Check defrost element continuity
-
Put cabinet into manual defrost, wait for defrost relay to
“click” on (2 ½ minutes after pressing buttons)
-
If no “click”, check power/control module
-
If “click” heard, check the defrost heater 110v output at the
power/control module
* Sensors
-
Check display for fault codes 0-5
-
Sensors above or below limit, refer thermistor service
table in service manual
* Door switch fault
-
Check that no fault code is shown on the display
-
Check that PC / FC doors activate reed switches
-
Check also reed switches with magnet
-
Check wiring harness to power/control module
-
Check wiring harness to console board
FAULT DISPLAYED, NO ALARM
* Display flashing fault code,
but no alarm sounding
-
Alarm has been switched off by user
-
Piezo alarm faulty on board, replace board
LIGHT NOT FUNCTIONING
* Blown bulb
-
Check power supply to socket 7Volts, if nil check plug at
display module
-
Check continuity of bulb, nil replace
* Cabinet type
-
Power/control module not initialised, close FC door and
press compartment select button
* Poor connection
-
Spread halogen bulb legs
-
Check lamp holder, replace where possible
-
Check connector on display module
CONSOLE - NO L.E.D. LIGHTS
* Power/control module no
power
-
Check harness and plugs on 5 way display module
harness at both ends
-
Initialize cabinet
RASPBERRY NOISE
* Power/control module not
initialized
-
Initialise power/control module, close FC door and push
any button on display module
-
If raspberry noise still made, check door switches
NOISY FAN PC
* Wires touching
-
Tuck wires away from fan blade
* Faulty fan
-
Fit replacement
NOISY FAN FC
* Ice on cover
-
Clear ice off cover and check doors are sealing
* Ice on grill
-
Clear ice off grill and check doors are sealing
* Fan off mountings
-
Refit
* Wires touching
-
Tuck wires away from fan blade
* Capillary touching
-
Shift capillary from fan area make sure it is not touching
any part of the cabinet
* Fan motor noisy
-
Fit replacement
* Wires too tight
-
Re route wiring
ICE BUILD UP IN
COMPARTMENT
* Doors sealing
-
Check gaskets sealing, adjust gaskets
-
Check fans are operating
REFRIGERATION NOISE
* Popping, farting
-
Evacuate recharge with ISCEON 49, check alignment of
capillary
* Gurgling, whistling
-
Check alignment of capillary and apply sound dampening
tape