46
9.2 “T”
Models
PC TOO COLD
* FC fan not going (alarm will
sound and fault code will be
displayed)
-
Check power to plug
-
Check polarity
-
Replace fan
* Short of gas
-
Check run percentage, if high check evaporator
-
Check fully flooded evaporator, check for leak
* PC sensor inaccurate
-
Check calibration of sensor ice point using interface binary
or refer to thermistor resistance table in service manual
PC TOO WARM
* Evaporator iced up
-
Check defrost element, check continuity
-
Check door seal/door left open
* No refrigeration
-
Does cabinet run? If no, check power supplies. If yes,
check refrigeration system
-
If running, check for live frost/fully flooded evaporator. If
not, check for leak
* Fans not working (alarm will
sound and fault code will be
displayed)
-
Is there a 12Volt supply, PC light working
-
If yes, check fan connection(s) at fan end, also at
power/control module end of the harness
-
If no, check for power/control module failure
* Power/control module
failure
-
Are lamp / interface L.E.D.’s working
-
If not check display module connection
-
If OK is compressor running ?
-
If not replace power/control module
* PC delivery duct blocked
-
De-ice area behind chassis
-
FC TOO COLD
* FC sensor location
-
Check set temperature
-
Sensor clipped and located in correct position
* Faulty sensor
-
Check calibration of sensor ice point using interface binary
or refer to thermistor resistance table in service manual
* PC faulty fanr
-
Check PC cooling, fan running
FC TOO WARM
* No refrigeration
-
Does cabinet run? If no check power supplies. If yes
check refrigeration system
-
If running, check for live frost/fully flooded evaporator. If
not, check for leak
TOTAL CABINET TOO WARM
* No refrigeration
-
Does cabinet run? If no check power supplies. If yes
check refrigeration system
-
If running, check for live frost/fully flooded evaporator
-
If not, check for leak
-
Compressor is not running, check power/control module
voltage outputs
-
Check compressor and ancillaries
FC COOLING - PC WARMING
* Iced up evaporator
-
Check defrost circuit continuity
-
Doors sealing, adjust
-
Is PC fan is running? (alarm will sound and fault code will
be displayed if faulty). If not, refer PC too warm
Summary of Contents for 790 Active Smart