FISCHER Mess- und Regeltechnik GmbH
Order Codes | 7
BA_EN_MA15_ATEX
29 / 36
[10]
Special functions
1
Zero-point correction with setting
screw
2
Zero-point correction micro adjust-
ment indicator
3
Zero-point correction with setting
screw
Adjustable marker needle
4
Zero-point correction with setting
screw
Resettable drag needle
♣)
5
Zero-point correction micro adjust-
ment indicator
Adjustable marker needle
6
Zero-point correction micro adjust-
ment indicator
Resettable drag needle
♣)
♣)
only for measuring ranges from 60 mbar
[11.12] ATEX
0A
Non-electrical unit
(without switch contacts)
II 2G Ex h IIC T4 Gb
II 2D Ex h IIICT95°C Db
1B
Unit with magnetic spring contacts
KE##M##0B4H2
Simple electrical operating equipment acc.
to DIN EN 60079-11
II 2G Ex h IIC T4 Gb
1C
Unit with inductive contacts KE##I##0C0H2 II 2G Ex h IIC T4 Gb
II 2D Ex h IIIC T95°C Db
2D
Unit with capacitive rotation angle trans-
ducer KE0905#9
II 2G Ex h IIC T4 Gb